$1,524.99

    Achieve superior accuracy in water quality analysis with the HI93414 Portable Turbidity and Chlorine Meter. This combination nephelometer and photometer precisely measures both turbidity (NTU), meeting EPA 180.1 standards, and chlorine (ppm), adapted from EPA 330.5, ensuring reliable drinking water assessment. Supplied with NIST traceable standards for calibration and verification, this meter guarantees dependable results in the field or lab.

    • Features Fast Tracker™ T.I.S. for efficient sample tagging and data management.
    • Offers convenient USB connectivity for seamless data transfer to a computer.
    • Provides flexible power options, operating on batteries or via a line voltage connection.

    *Products classified as Dangerous Goods can only be shipped via ground.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b

The HI93414 is a versatile, portable meter engineered for precise measurement of two critical water quality parameters: turbidity and chlorine. Leveraging an advanced optical system, this instrument delivers accurate and consistent readings by effectively minimizing interference from stray light and color in the sample. Built-in calibration using supplied standards compensates for any fluctuations in the tungsten light source. For chlorine analysis, the colorimeter employs a narrow 525 nm band interference filter, ensuring optimal wavelength for both free and total chlorine detection. All measurements are conducted in 25 mm round cuvettes made of specialized optical glass, which maximizes the repeatability of both turbidity and chlorine measurements.

Key Features at a Glance:

  • Triple Measurement Modes: Offers ratio mode for turbidity, free chlorine, and total chlorine. Turbidity range: 0.00 to 1000 NTU. Free/Total Chlorine range: 0.00 to 5.00 mg/L (ppm).
  • Multiple Reading Options: Choose between normal, continuous, or signal averaging measurement modes to suit your application.
  • EPA Compliant: Meets and exceeds EPA and Standard Methods requirements for both turbidity and colorimetric chlorine measurements. EPA mode ensures turbidity readings are rounded for compliant reporting.
  • Comprehensive Calibration: Perform two, three, or four-point turbidity calibration using the included (<0.10, 15.0, 100, and 750 NTU) standards. Customize calibration points with user-prepared standards. For chlorine, utilize the 1.00 mg/L (ppm) CAL Check™ standard for calibration and verification.
  • AMCO AEPA-1 Primary Turbidity Standards: The supplied AMCO AEPA-1 standards are USEPA-recognized primary standards, non-toxic, uniform styrene divinylbenzene polymer spheres, offering reusability and long-term stability.
  • CAL Check™ for Chlorine: Validate the chlorine colorimeter's performance at any time using HANNA's exclusive, NIST traceable CAL Check™ standards, each provided with a Certificate of Analysis for traceability.
  • Fast Tracker™ T.I.S.: Simplify data collection and management in the field by recording time and location of measurements using iButton® tags at sampling points.
  • GLP Data Functionality: Ensures traceability of calibration conditions, including calibration points, date, and time.
  • Extensive Data Logging: Store up to 200 measurements in internal memory for later recall.
  • Effortless Data Transfer: Download logged data to a Windows PC via RS232 or USB ports using the HI92000 software for further analysis and storage.
  • Backlit LCD: Provides a clear, user-friendly interface with step-by-step guidance through routine operation and calibration.

Turbidity is a crucial indicator of drinking water quality. Beyond aesthetics, controlling turbidity is a vital safeguard against waterborne pathogens. In natural water sources, turbidity measurements assess overall water quality and its suitability for aquatic life. Historically, wastewater treatment relied heavily on turbidity control, and even today, final turbidity measurements are essential for verifying compliance with regulatory standards.

Water turbidity is an optical property that describes the scattering and absorption of light rather than its transmission. Suspended solids are the primary cause of light scattering in liquids. Higher turbidity correlates with increased light scattering. Even ultrapure liquids exhibit some degree of light scattering, meaning zero turbidity is practically unattainable.

Drinking water treatment facilities using surface water sources (lakes and rivers) are mandated by the EPA to monitor and report turbidity. The EPA Method 180.1 outlines specific requirements for nephelometers and reporting measurements, including an applicable range of 0-40 NTU, a tungsten lamp light source (2200-3000°K), a maximum 10 cm path length for incident and scattered light, a detector centered at 90° with a spectral peak response between 400 nm and 600 nm, and a sensitivity to detect turbidity differences of 0.02 NTU or less in low turbidity waters.

Reporting Requirements According to EPA Method 180.1:

NTU reading  Rounded to nearest
0.0 - 1.0 0.05
1 - 10 0.1
10 - 40 1
40 - 100  5
100 - 400 10
400 - 1000 50
> 1000 100

The HI93414 turbidity and chlorine meter meets and exceeds the performance criteria specified by EPA Method 180.1 and Standard Methods for the Examination of Water and Wastewater 2130 B.

HI93414 Turbidity and Chlorine Meter Light Diagram

Principle of Operation

The light beam that passes through the sample is scattered in all directions. The intensity and pattern of the scattered light is affected by many variables, such as wavelength of the incident light, particle size and shape, refractive index, and color. The optical system of the HI93414 includes a tungsten filament lamp, a scattered light detector (90°) and a transmitted light detector (180°).

In the ratio turbidimeter range, the microprocessor of the instrument calculates the NTU value from the signals that reach the two detectors by using an effective algorithm that corrects and compensates for interferences of color. The optical system and measuring technique also compensate for fluctuations in lamp intensity, minimizing the need for frequent calibration.

In the non-ratio turbidimeter range, the NTU value is calculated from the signal on the scattered light detector (90°). This method offers a high linearity on the low range but is more sensitive to lamp intensity fluctuations. The lower detection limit of a turbidimeter is determined by stray light that is detected by the sensors but not caused by light scattering from suspended particles. The optical system of the HI93414 is designed to have very low stray light, providing highly accurate results for low turbidity samples.

The HI98703-11 AMCO AEPA-1 standards ensure that measurements are traceable to a primary reference materials. These standards are used for calibration and performance verification of the HI93414 turbidity meter.

Supplied with Certificate of Analysis:
  • Lot number
  • Expiration date
  • Standard value @ 25 °C
  • Reference meter NIST traceable
Provided storage containers:
  • Light tight
  • Protects from accidental breakage
AMCO AEPA-1 Turbidity Standards for HI93414
HI93414 CAL Check Chlorine Standards

CAL Check™ standards with certificate

The HI93414-11 free and total chlorine CAL Check™ standards are used for calibration and performance verification of the HI93414.

Supplied with Certificate of Analysis:
  • Lot number
  • Expiration date
  • Standard value @ 25 °C
  • Reference meter NIST traceable
Provided storage containers:
  • Light tight
  • Protects from accidental breakage
    Specification Detail
    sku HI93414-01
    NTU Range 0.00 to 9.99 NTU
    10.0 to 99.9 NTU
    100 to 1000 NTU
    NTU Resolution 0.01 NTU (0.00 to 9.99 NTU)
    0.1 NTU (10.0 to 99.9 NTU)
    1 NTU (100 to 1000 NTU)
    NTU Accuracy ±2% of reading plus 0.02 NTU
    Range Selection Automatic
    Turbidity Repeatability ±1% of reading or 0.02 NTU, whichever is greater
    Stray Light < 0.02 NTU
    Free Chlorine Range 0.00 to 5.00 mg/L
    Total Chlorine Range 0.00 to 5.00 mg/L
    Chlorine Resolution 0.01 mg/L (0.00 to 3.50 mg/L)
    0.10 mg/L (above 3.50 mg/L)
    Chlorine Accuracy ±0.02 mg/L @ 1.00 mg/L
    Chlorine Detector Silicon photocell with 525 nm narrow band interference filters
    Chlorine Method Adaptation of the USEPA Method 330.5 and Standard Method 4500-Cl G. The reaction between chlorine and DPD reagent causes a pink tint in the sample.
    Chlorine Standards 1 mg/L free chlorine, 1 mg/L total chlorine
    Chlorine Calibration One-point calibration
    Turbidity Light Detector Silicon Photocell
    Turbidity Method Ratio Nephelometric Method (90°), ratio of scatter and transmitted light
    Adaptation of the USEPA Method 180.1 and Standard Method 2130 B.
    Measuring Mode Normal, Average, Continuous.
    Turbidity Standards <0.1, 15, 100 and 750 NTU
    Calibration Two, three or four-point calibration
    Light Source Tungsten filament lamp
    Lamp Life greater than 100,000 readings
    Display 60 x 90mm LCD with backlight
    LOG Memory 200 records
    Serial Interface RS232 or USB 1.1
    Environment 0°C (32°F) to 50°C (122°F) max 95% RH non-condensing
    Power Supply 4 x 1.5V AA alkaline batteries or AC adapter
    Auto Shut-Off After 15 minutes of non-use
    Dimensions 224 x 87 x 77 mm (8.8 x 3.4 x 3.0'')
    Weight 512g (18 oz.)
    Warranty 2 years

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.
    HI93414 Portable Turbidity and Chlorine Meter Instruction Manual
    Download
    Manual

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY
Expanded View

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)