Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Hanna HI937554-53 Pool Line Chlorine Removal Reagent Default Title Photometer Reagents Hanna Instruments
Hanna HI937554-53 Pool Line Chlorine Removal Reagent Default Title Photometer Reagents Hanna Instruments

Hanna HI937554-53 Pool Line Chlorine Removal Reagent

$16.49

    Complete the named HI971044 alkalinity preparation step. Keep the exact Pool Line chlorine-removal adjunct ready for your HI971044 alkalinity workflow. HI937554-53 is the separately orderable retail refill named in the six-digit instrument’s required-reagents table—not the similarly numbered legacy remover.

    • HI971044: required one-drop Pool Line alkalinity step
    • Pretreatment refill, not a complete alkalinity test or chlorine assay
    • Use with separately supplied HI775-26 analytical alkalinity reagent

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

Complete the named HI971044 alkalinity preparation step

Keep the exact Pool Line chlorine-removal adjunct ready for your HI971044 alkalinity workflow. HI937554-53 is the separately orderable retail refill named in the six-digit instrument’s required-reagents table—not the similarly numbered legacy remover.

Hanna HI937554-53 factory chlorine-remover photograph
Factory photograph of HI937554-53 with Pool Line carton.

Choose by the exact model and full reagent code

Choose the full HI937554-53 code for the exact HI971044 method in MAN971044 11/25, covering software v1.02 and higher. Its one-drop chlorine-removal step is required in that alkalinity procedure. Do not borrow the optional wording from the older HI97104 method or assume cross-model interchangeability.

What this refill supplies

This is the named HI937554-53 Pool Line chlorine-remover refill. The official retail page calls it a chlorine removal kit; it is an adjunct, not a complete alkalinity test kit. No supplied liquid volume, bottle count or total test capacity is inferred from the factory photo or the one-drop method dose.

Build the complete alkalinity workflow

Have your HI971044 photometer, the correct cuvette with stopper/cap, a 1 mL syringe, a clean wipe and separately supplied HI775-26 alkalinity reagents. HI775S performs the analytical color reaction; the chlorine remover does not replace it.

The preparation step that protects your result

Select Alkalinity and zero with 10 mL unreacted sample in the capped cuvette. Remove the cuvette, add one drop of HI937554-53 and swirl to mix. Add 1 mL HI775S with a syringe, replace stopper and cap, invert five times, reinsert in the correct orientation and read. The result is alkalinity in mg/L as CaCO3, not chlorine concentration.

Handling and documentation

The official HI937554-53 SDS directory links a US sheet labeled HI937554-530. That is the directory-linked component identifier, not a replacement retail MPN or a chemical-alias claim. Follow the supplied label and applicable SDS for handling, storage and disposal; a component sheet is not a whole-kit transport or shipping guarantee.

Frequently Asked Questions

Why is the additional 5 in HI937554-53 important?

The exact US offer and factory bottle photograph both identify HI937554-53, and the HI971044 manual names it as Pool Line Chlorine Removal Reagent. It is a distinct retail listing from legacy HI93755-53, not a spelling correction or asserted chemical alias.

Is the one-drop step optional on HI971044?

No. MAN971044 11/25 lists HI937554-53 under REQUIRED REAGENTS for alkalinity and instructs adding one drop and swirling after zeroing. The conditional wording for the older HI97104 is not applied to this method.

Which HI971044 manual is referenced?

The referenced MAN971044 11/25 manual covers software v1.02 and higher. Confirm your exact six-digit model and software, and follow the full instrument procedure and prompts.

Does this refill measure chlorine?

No. It is a chlorine-removal adjunct in the alkalinity preparation. It is not a free- or total-chlorine measuring reagent and does not replace the instrument’s chlorine test reagents.

What else is needed for an alkalinity result?

You need the HI971044, its correct cuvette, stopper/cap, an accurate 1 mL syringe and the HI775S analytical reagent supplied through HI775-26. Zero the unreacted sample, add one drop remover, swirl, add 1 mL HI775S, invert five times and read as directed.

What volume and number of tests does one order supply?

No commercial fill volume or per-order test count is established by the verified offer and exact-model method. The one-drop dose describes use, not the refill’s capacity. The factory image is shown for identity rather than as a packing census.

Why does the SDS say HI937554-530?

The official SDS directory for retail HI937554-53 links US PDF 15637 labeled HI937554-530. The document is retained under that component code; the product you are selecting remains retail MPN HI937554-53. This does not assert a chemical alias or whole-kit transport classification.

Can I use it on HI97104 or other alkalinity meters?

This page supports the exact HI971044 method and does not establish cross-model substitution. The older five-digit HI97104 names HI93755-53. Choose by the full model and reagent codes rather than the shared price or alkalinity name.

    Product Specifications

    SpecificationDetail
    Catalog number / retail MPNHI937554-53
    Product roleChlorine-removal sample pretreatment for freshwater alkalinity; not a chlorine measurement reagent
    Exact method referenceHI971044, MAN971044 11/25, software v1.02+
    Method dose1 drop; required in exact HI971044 alkalinity procedure
    Analytical reagent, separateHI775S via HI775-26 freshwater alkalinity reagent refill
    Commercial volume / test capacityNot established; no dose-to-capacity inference
    US SDS identifierHI937554-530 (official retail-code directory-linked component)

    Ordering Information

    SpecificationDetail
    HI937554-53Pool Line Chlorine Removal Reagent refill; photometer, analytical reagent and cuvette separate

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.