Hanna HI93754G-25 COD ISO MR Reagent Vials, 25 Vials Default Title Photometer Reagents Hanna Instruments
Hanna HI93754G-25 COD ISO MR Reagent Vials, 25 Vials Default Title Photometer Reagents Hanna Instruments

Hanna HI93754G-25 COD ISO MR Reagent Vials, 25 Vials

$87.99

    Keep ISO medium-range COD work on the right scale. Match the exact refill to your laboratory method.

    • ISO 15705:2002 COD MR: 0–1000 mg/L as O₂
    • 25 nominal pre-dosed vials; blank and QC reduce sample yield
    • Exact HI97106 / HI83314 / HI83399 method fit; digestion required

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

Keep ISO medium-range COD work on the right scale.

Refill your established chemical oxygen demand workflow with 25 pre-dosed HI93754G-25 reagent vials. The exact ISO reagent instructions and HI97106, HI83314 and HI83399 methods specify 0–1000 mg/L as O₂ for this formulation—not the higher range used by other medium-range COD reagents.

Official Hanna HI93754G-25 reference packaging
Official Hanna HI93754G-25 reference pack. Printed lot and expiration information illustrate packaging, not a guarantee for supplied stock.

Check the exact catalog number and method

Use the exact HI93754G-25 ISO 15705:2002 method on HI97106, HI83314 or HI83399. Confirm the instrument method, required vial adapter and digestion equipment before ordering; a generic COD MR label is not enough to establish reagent interchangeability.

What one pack supplies

One sellable pack contains 25 ready-to-use, pre-dosed reagent vials. Each initial determination workflow needs a sample vial and a reagent blank vial. This is a nominal vial count, not a promise of 25 reportable sample results: blanks, QC, repeats and any extra measurement sets consume additional vials.

Plan the digestion before starting

The documented procedure uses 2.0 mL sample and 2.0 mL deionized water in separate reagent vials, followed by digestion at 150 °C for 120 minutes. Follow the complete model-specific instructions for mixing, heating, cooling and optical reading. Use the required adapter for your exact instrument, and never insert hot vials into it.

Make the blank part of your method

Prepare blank and sample from the same reagent lot. The manuals allow reuse of an appropriately prepared same-lot blank and recommend a fresh blank for each measurement set for improved accuracy. Keep its identity and preparation records; do not treat an old blank from another lot as an interchangeable zero.

Check the sample matrix and reporting requirement

The ISO instructions specify chloride below 2000 mg/L; follow their dilution instructions for higher concentrations and account for dilution when reporting the sample. Homogenize samples with settling solids as instructed. Method fit does not establish universal EPA approval or acceptance for every permit or reporting program.

Handle, store and ship as hazardous chemistry

The US HI93754G-0 component SDS identifies sulfuric acid, dichromate, silver sulfate and mercury(II) sulfate. This is not a mercury-free refill. Use the prescribed PPE and handling controls, keep unused vials in their packaging in a cool, dark place, and arrange compliant spent-reagent disposal. The US product is classified as Dangerous Goods and ships by ground only; no delivery date is promised.

Frequently Asked Questions

What is the correct HI93754G-25 range?

0–1000 mg/L as O₂. The exact ISO instructions and all three referenced instrument methods take priority over conflicting generic retailer prose or comparison tables.

Does 25 vials mean 25 reportable samples?

No. A reagent blank consumes a vial, and additional blanks, QC and repeats use more. Plan your sample throughput from the complete method rather than the nominal pack count.

Which photometers have a documented method?

HI97106, HI83314 and HI83399 have specific HI93754G-25 procedures. Confirm the exact COD program and required adapter in your model manual; this is not a universal photometer refill.

What sample and digestion steps must I plan for?

The method calls for 2.0 mL sample, a separate 2.0 mL deionized-water reagent blank, and digestion at 150 °C for 120 minutes. Use the full instructions for safe mixing, cooling and reading.

Can I reuse a blank from another reagent lot?

No. Blank and sample must use the same reagent lot. Follow the manual’s blank reuse conditions and run a blank for each measurement set for improved accuracy.

Is this mercury-free or universally EPA approved?

Neither claim is appropriate. The actual component SDS lists mercury(II) sulfate; this is the ISO 15705:2002 formulation. Confirm acceptance for your own reporting program.

Can I test a high-chloride or settling sample directly?

Check the exact method first. ISO instructions require chloride below 2000 mg/L and direct dilution when higher. Homogenize settling solids as instructed; include dilution factors and validated QC.

How should I order and store this pack?

Order HI93754G-25 as one pack of 25 vials, not individual tests. Ground-only Dangerous Goods handling applies. Keep unused vials cool and dark in their packaging and use supplied-lot expiry information; the reference photo does not establish shelf life.

    Product Specifications

    SpecificationDetails
    Manufacturer catalog numberHI93754G-25
    Supplied pack25 pre-dosed reagent vials
    Analyte / reporting unitChemical oxygen demand, mg/L as O₂
    Exact reagent range0–1000 mg/L as O₂
    Method referenceISO 15705:2002
    Documented instrumentsHI97106, HI83314, HI83399; exact method and adapter required
    Sample / blank water2.0 mL sample; 2.0 mL deionized water in a separate blank vial
    Digestion150 °C for 120 minutes; cool per instrument instructions
    Blank planningSame reagent lot; blank and QC consume vials
    Chloride method limitBelow 2000 mg/L; follow ISO dilution instructions when higher
    ShippingDangerous Goods; ground only
    Physical vial diameterNot specified here; confirm exact supplied vial and adapter with Hanna

    Ordering Information

    Catalog numberPack contents
    HI93754G-2525 pre-dosed vials; blank/QC consume vials

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.