Hanna HI93754F-25 COD LR ISO Reagent Vials, 25 Vials Default Title Photometer Reagents Hanna Instruments
Hanna HI93754F-25 COD LR ISO Reagent Vials, 25 Vials Default Title Photometer Reagents Hanna Instruments

Hanna HI93754F-25 COD LR ISO Reagent Vials, 25 Vials

$87.99

    Refill the low-range ISO COD method with the right chemistry. Keep the matched reagent refill ready for your established method.

    • 0–150 mg/L as O2; ISO 15705:2002 formulation
    • 25 actual vials; required blank and QC reduce sample yield
    • 150 °C / 120-minute digestion; heater, DI water and pipetting tools separate

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

Refill the low-range ISO COD method with the right chemistry.

Keep a validated ISO 15705:2002 low-range COD workflow supplied with HI93754F-25. Its 25 pre-dosed reagent vials cover 0–150 mg/L as O2 when used with the documented photometer procedure and separate heated digestion. Choose it by method family as well as range: this ISO formulation contains mercury and is neither the mercury-free refill nor a universally approved EPA replacement.

Official Hanna HI93754F-25 reagent reference packaging
Official Hanna HI93754F-25 packaging reference, illustrating the refill and pre-dosed vials. Printed lot/expiry markings are illustrative, not the lot or expiration of supplied stock.

Match the refill to the complete method

Use HI93754F-0 reagent in the exact-model COD LR procedure: HI97106 selects COD LR; HI83314 and HI83399 select COD LR (16). The verified range is 0–150 mg/L as O2. Follow the instrument’s specified vial adapter and insertion instructions for both zero and read. Official sources conflict on physical vial diameter, so this listing does not assert the diameter of supplied vials or universal adapter fit.

Choose chemistry and range together

HI93754F-25 is the orderable pack; HI93754F-0 is the component code identified in the instrument method and US Safety Data Sheet. The ISO family attribution is 15705:2002. A low-range label alone does not make this equivalent to the mercury-free or EPA formulations.

Match the exact instrument procedure

Use HI93754F-0 reagent in the exact-model COD LR procedure: HI97106 selects COD LR; HI83314 and HI83399 select COD LR (16). The verified range is 0–150 mg/L as O2. Follow the instrument’s specified vial adapter and insertion instructions for both zero and read. Official sources conflict on physical vial diameter, so this listing does not assert the diameter of supplied vials or universal adapter fit.

Prepare the blank as deliberately as the sample

Prepare one vial with 2 mL sample and a separate same-lot blank vial with 2 mL deionized water. Follow the full manual’s mixing precautions, then digest at 150 °C for 120 minutes in a separate heater. Cool exactly as directed: allow the initial cooling interval, invert while still warm when instructed, then rack until room temperature without shaking or inverting during final cooling. Never place a hot vial in the photometer adapter. Zero on the blank before reading the sample.

Count vials, not promised results

The pack contains 25 actual pre-dosed vials. A reagent blank consumes one of those vials, leaving 24 sample vials when one blank is prepared for a batch. This explains the benchtop manuals’ 24-test ordering count versus the retail 25-test label. Same-lot blanks and samples are required; follow the manual’s blank-reuse rules and run a blank for each measurement set for improved accuracy. Additional blanks, QC checks, repeats or failed preparations consume more vials. There is no guarantee of 25 reportable results.

Check the matrix before interpreting COD

ISO instructions require chloride below 2000 mg/L. Dilute higher-chloride samples as directed, account for the dilution and keep the result within the method range. This condition belongs to the ISO formulation; it is not a permission to use mercury-free reagents in chloride-containing samples.

Have the complete digestion station ready

Provide a compatible photometer and its specified adapter, a separate digestion reactor capable of 150 °C for 120 minutes, deionized water, accurate 2 mL pipetting/measuring tools and separate clean tips, a cooling rack, and the prescribed safety equipment. The photometer does not heat the vials. A safety shield is strongly recommended by the instrument manuals and required by the ISO reagent instructions; those instructions specify class A glass pipettes.

Confirm reporting acceptance before use

ISO 15705:2002 identifies this formulation’s method family. It is different from the EPA reagent family and cannot be treated as an automatically interchangeable EPA substitute. A common instrument-manual EPA-adaptation heading does not establish universal EPA/ISO approval. Confirm the laboratory’s SOP, matrix validation and local reporting acceptance before regulatory use.

Handle and ship as hazardous chemistry

This ISO formulation contains mercury(II) sulfate as well as sulfuric acid and chromium-containing chemistry. It is not mercury-free. Treat fresh reagent and reacted vials as hazardous chemical materials; use the current US component SDS, suitable PPE, ventilation and a compliant waste service. Do not put spent vials in ordinary trash or pour them down the drain. Hanna classifies this product as Dangerous Goods, with ground-only shipping. An SDS air-transport classification is not permission to ship by air. No dispatch date or freight quote is promised.

Manage received stock by its own markings

Keep unused vials in their original packaging in a cool, dark place, subject to the current SDS storage precautions. Check the lot and expiry on received stock; a reference photo does not establish your lot, expiry or available shelf life. No numeric storage temperature or shipping weight is asserted here.

Frequently Asked Questions

What does one order quantity contain?

The pack contains 25 actual pre-dosed vials. A reagent blank consumes one of those vials, leaving 24 sample vials when one blank is prepared for a batch. This explains the benchtop manuals’ 24-test ordering count versus the retail 25-test label. Same-lot blanks and samples are required; follow the manual’s blank-reuse rules and run a blank for each measurement set for improved accuracy. Additional blanks, QC checks, repeats or failed preparations consume more vials. There is no guarantee of 25 reportable results.

Which photometers and method selections are documented?

Use HI93754F-0 reagent in the exact-model COD LR procedure: HI97106 selects COD LR; HI83314 and HI83399 select COD LR (16). The verified range is 0–150 mg/L as O2. Follow the instrument’s specified vial adapter and insertion instructions for both zero and read. Official sources conflict on physical vial diameter, so this listing does not assert the diameter of supplied vials or universal adapter fit.

How much sample and blank water do I need?

Prepare one vial with 2 mL sample and a separate same-lot blank vial with 2 mL deionized water. Follow the full manual’s mixing precautions, then digest at 150 °C for 120 minutes in a separate heater. Cool exactly as directed: allow the initial cooling interval, invert while still warm when instructed, then rack until room temperature without shaking or inverting during final cooling. Never place a hot vial in the photometer adapter. Zero on the blank before reading the sample.

Is a digestion heater or pipette included?

Provide a compatible photometer and its specified adapter, a separate digestion reactor capable of 150 °C for 120 minutes, deionized water, accurate 2 mL pipetting/measuring tools and separate clean tips, a cooling rack, and the prescribed safety equipment. The photometer does not heat the vials. A safety shield is strongly recommended by the instrument manuals and required by the ISO reagent instructions; those instructions specify class A glass pipettes.

What chloride limitation applies?

ISO instructions require chloride below 2000 mg/L. Dilute higher-chloride samples as directed, account for the dilution and keep the result within the method range. This condition belongs to the ISO formulation; it is not a permission to use mercury-free reagents in chloride-containing samples.

Can I use this for regulated reporting?

ISO 15705:2002 identifies this formulation’s method family. It is different from the EPA reagent family and cannot be treated as an automatically interchangeable EPA substitute. A common instrument-manual EPA-adaptation heading does not establish universal EPA/ISO approval. Confirm the laboratory’s SOP, matrix validation and local reporting acceptance before regulatory use.

Is this reagent nonhazardous or mercury-free?

This ISO formulation contains mercury(II) sulfate as well as sulfuric acid and chromium-containing chemistry. It is not mercury-free. Treat fresh reagent and reacted vials as hazardous chemical materials; use the current US component SDS, suitable PPE, ventilation and a compliant waste service. Do not put spent vials in ordinary trash or pour them down the drain.

What shipping and storage precautions apply?

Dangerous Goods: ground-only shipping. No air-shipping permission or delivery date is promised. Store unused vials in their original packaging in a cool, dark place and follow the current SDS. Inspect actual lot/expiry markings on receipt; printed dates in photographs are illustrative only.

    Product Specifications

    SpecificationDetail
    Orderable packHI93754F-25 — 25 pre-dosed reagent vials
    Component/SDS codeHI93754F-0
    Parameter and rangeChemical oxygen demand (COD), 0–150 mg/L as O2
    FormulationISO 15705:2002 dichromate; contains mercury(II) sulfate
    HI97106 procedureCOD LR
    HI83314 / HI83399 procedureCOD LR (16); exact-model adapter instructions apply
    Sample volume2 mL per sample vial
    Required blank2 mL deionized water in one same-lot reagent vial
    Heated digestion150 °C for 120 minutes; separate reactor required
    Result capacity25 vials, not 25 guaranteed results; one blank leaves 24 sample vials before extra QC/repeats
    Chloride limitationBelow 2000 mg/L per ISO instructions; higher concentrations require directed dilution
    Reporting acceptanceApplication-specific verification required; no universal EPA/ISO approval
    Required separatelyPhotometer, specified adapter, reactor, DI water, accurate pipetting/measuring tools, cooling rack and safety equipment
    Hazards and shippingAcidic chromium/mercury chemistry; Dangerous Goods, ground-only
    Adapter selectionFollow your exact model’s COD adapter instructions; do not choose solely by generic vial size.

    Ordering Information

    Catalog numberReagent pack
    HI93754F-2525 pre-dosed reagent vials — blank and QC consumption reduce sample yield

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.