Hanna HI93754E-25 COD MR Mercury-Free Reagent Vials, 25 Vials Default Title Photometer Reagents Hanna Instruments
Hanna HI93754E-25 COD MR Mercury-Free Reagent Vials, 25 Vials Default Title Photometer Reagents Hanna Instruments

Hanna HI93754E-25 COD MR Mercury-Free Reagent Vials, 25 Vials

$69.29

    Cover the medium COD range with a chloride-free workflow. Keep the matched reagent refill ready for your established method.

    • 0–1500 mg/L as O2; mercury-free, chloride must be absent
    • 25 actual vials; required blank and QC reduce sample yield
    • 150 °C / 120-minute digestion; heater, DI water and pipetting tools separate

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

Cover the medium COD range with a chloride-free workflow.

HI93754E-25 supplies the mercury-free medium-range COD chemistry for samples expected within 0–1500 mg/L as O2. Keep that wider concentration window separate from sample suitability: chloride must still be absent. Each pack contains 25 pre-dosed vials for a compatible, already-equipped laboratory workflow; blanking, digestion and quality-control consumption remain part of every stock plan.

Official Hanna HI93754E-25 reagent reference packaging
Official Hanna HI93754E-25 packaging reference, illustrating the refill and pre-dosed vials. Printed lot/expiry markings are illustrative, not the lot or expiration of supplied stock.

Match the refill to the complete method

Use HI93754E-0 reagent in the exact-model COD MR procedure: HI97106 selects COD MR; HI83314 and HI83399 select COD MR (16). The verified range is 0–1500 mg/L as O2. Follow the instrument’s specified vial adapter and insertion instructions for both zero and read. Official sources conflict on physical vial diameter, so this listing does not assert the diameter of supplied vials or universal adapter fit.

Choose chemistry and range together

HI93754E-25 is the orderable pack; HI93754E-0 is the component code identified in the instrument method and US Safety Data Sheet. The medium-range mercury-free formulation is designed for chloride-free samples. Do not select it only because its range matches the expected number.

Match the exact instrument procedure

Use HI93754E-0 reagent in the exact-model COD MR procedure: HI97106 selects COD MR; HI83314 and HI83399 select COD MR (16). The verified range is 0–1500 mg/L as O2. Follow the instrument’s specified vial adapter and insertion instructions for both zero and read. Official sources conflict on physical vial diameter, so this listing does not assert the diameter of supplied vials or universal adapter fit.

Prepare the blank as deliberately as the sample

Prepare one vial with 2 mL sample and a separate same-lot blank vial with 2 mL deionized water. Follow the full manual’s mixing precautions, then digest at 150 °C for 120 minutes in a separate heater. Cool exactly as directed: allow the initial cooling interval, invert while still warm when instructed, then rack until room temperature without shaking or inverting during final cooling. Never place a hot vial in the photometer adapter. Zero on the blank before reading the sample.

Count vials, not promised results

The pack contains 25 actual pre-dosed vials. A reagent blank consumes one of those vials, leaving 24 sample vials when one blank is prepared for a batch. This explains the benchtop manuals’ 24-test ordering count versus the retail 25-test label. Same-lot blanks and samples are required; follow the manual’s blank-reuse rules and run a blank for each measurement set for improved accuracy. Additional blanks, QC checks, repeats or failed preparations consume more vials. There is no guarantee of 25 reportable results.

Check the matrix before interpreting COD

Chloride must be absent. The HI83314 and HI83399 methods state this specifically for mercury-free reagent. Do not apply the generic 2000 mg/L chloride threshold to this formulation, or assume a routine dilution makes a chloride-containing sample suitable. Confirm the matrix and the validated method before ordering.

Have the complete digestion station ready

Provide a compatible photometer and its specified adapter, a separate digestion reactor capable of 150 °C for 120 minutes, deionized water, accurate 2 mL pipetting/measuring tools and separate clean tips, a cooling rack, and the prescribed safety equipment. The photometer does not heat the vials. A safety shield is strongly recommended by the instrument manuals. Homogenize samples with settling solids as directed; provide the necessary equipment separately.

Confirm reporting acceptance before use

This is the mercury-free dichromate formulation, not the mercury-containing EPA reagent. Hanna cautions that a mercury-free method may not be acceptable for reporting purposes. A shared instrument-manual EPA-adaptation heading is not automatic EPA equivalence or regulatory approval. Verify acceptance with your laboratory’s SOP and reporting authority before use.

Handle and ship as hazardous chemistry

Mercury-free does not mean safe, nonhazardous or suitable for ordinary trash. The reagent remains strongly acidic and contains chromium chemistry; the US SDS identifies sulfuric acid, silver sulfate and potassium dichromate. Use the required PPE and ventilation, and arrange hazardous chemical waste handling. Do not pour reacted material down the drain or dispose of spent vials with ordinary trash. Hanna classifies this product as Dangerous Goods, with ground-only shipping. An SDS air-transport classification is not permission to ship by air. No dispatch date or freight quote is promised.

Manage received stock by its own markings

Keep unused vials in their original packaging in a cool, dark place, subject to the current SDS storage precautions. Check the lot and expiry on received stock; a reference photo does not establish your lot, expiry or available shelf life. No numeric storage temperature or shipping weight is asserted here.

Frequently Asked Questions

What does one order quantity contain?

The pack contains 25 actual pre-dosed vials. A reagent blank consumes one of those vials, leaving 24 sample vials when one blank is prepared for a batch. This explains the benchtop manuals’ 24-test ordering count versus the retail 25-test label. Same-lot blanks and samples are required; follow the manual’s blank-reuse rules and run a blank for each measurement set for improved accuracy. Additional blanks, QC checks, repeats or failed preparations consume more vials. There is no guarantee of 25 reportable results.

Which photometers and method selections are documented?

Use HI93754E-0 reagent in the exact-model COD MR procedure: HI97106 selects COD MR; HI83314 and HI83399 select COD MR (16). The verified range is 0–1500 mg/L as O2. Follow the instrument’s specified vial adapter and insertion instructions for both zero and read. Official sources conflict on physical vial diameter, so this listing does not assert the diameter of supplied vials or universal adapter fit.

How much sample and blank water do I need?

Prepare one vial with 2 mL sample and a separate same-lot blank vial with 2 mL deionized water. Follow the full manual’s mixing precautions, then digest at 150 °C for 120 minutes in a separate heater. Cool exactly as directed: allow the initial cooling interval, invert while still warm when instructed, then rack until room temperature without shaking or inverting during final cooling. Never place a hot vial in the photometer adapter. Zero on the blank before reading the sample.

Is a digestion heater or pipette included?

Provide a compatible photometer and its specified adapter, a separate digestion reactor capable of 150 °C for 120 minutes, deionized water, accurate 2 mL pipetting/measuring tools and separate clean tips, a cooling rack, and the prescribed safety equipment. The photometer does not heat the vials. A safety shield is strongly recommended by the instrument manuals. Homogenize samples with settling solids as directed; provide the necessary equipment separately.

What chloride limitation applies?

Chloride must be absent. The HI83314 and HI83399 methods state this specifically for mercury-free reagent. Do not apply the generic 2000 mg/L chloride threshold to this formulation, or assume a routine dilution makes a chloride-containing sample suitable. Confirm the matrix and the validated method before ordering.

Can I use this for regulated reporting?

This is the mercury-free dichromate formulation, not the mercury-containing EPA reagent. Hanna cautions that a mercury-free method may not be acceptable for reporting purposes. A shared instrument-manual EPA-adaptation heading is not automatic EPA equivalence or regulatory approval. Verify acceptance with your laboratory’s SOP and reporting authority before use.

Is this reagent nonhazardous or mercury-free?

Mercury-free does not mean safe, nonhazardous or suitable for ordinary trash. The reagent remains strongly acidic and contains chromium chemistry; the US SDS identifies sulfuric acid, silver sulfate and potassium dichromate. Use the required PPE and ventilation, and arrange hazardous chemical waste handling. Do not pour reacted material down the drain or dispose of spent vials with ordinary trash.

What shipping and storage precautions apply?

Dangerous Goods: ground-only shipping. No air-shipping permission or delivery date is promised. Store unused vials in their original packaging in a cool, dark place and follow the current SDS. Inspect actual lot/expiry markings on receipt; printed dates in photographs are illustrative only.

    Product Specifications

    SpecificationDetail
    Orderable packHI93754E-25 — 25 pre-dosed reagent vials
    Component/SDS codeHI93754E-0
    Parameter and rangeChemical oxygen demand (COD), 0–1500 mg/L as O2
    FormulationMercury-free dichromate; chloride must be absent
    HI97106 procedureCOD MR
    HI83314 / HI83399 procedureCOD MR (16); exact-model adapter instructions apply
    Sample volume2 mL per sample vial
    Required blank2 mL deionized water in one same-lot reagent vial
    Heated digestion150 °C for 120 minutes; separate reactor required
    Result capacity25 vials, not 25 guaranteed results; one blank leaves 24 sample vials before extra QC/repeats
    Chloride limitationMust be absent; generic 2000 mg/L tolerance does not apply
    Reporting acceptanceApplication-specific verification required; no universal EPA/ISO approval
    Required separatelyPhotometer, specified adapter, reactor, DI water, accurate pipetting/measuring tools, cooling rack and safety equipment
    Hazards and shippingMercury-free but acidic chromium-containing hazardous chemistry; Dangerous Goods, ground-only
    Adapter selectionFollow your exact model’s COD adapter instructions; do not choose solely by generic vial size.

    Ordering Information

    Catalog numberReagent pack
    HI93754E-2525 pre-dosed reagent vials — blank and QC consumption reduce sample yield

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.