Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Hanna HI93754C-25 COD HR Dichromate Vials, 25 Pack Default Title Photometer Reagents Hanna Instruments
Hanna HI93754C-25 COD HR Dichromate Vials, 25 Pack Default Title Photometer Reagents Hanna Instruments

Hanna HI93754C-25 COD HR Dichromate Vials, 25 Pack

$87.99

    Measure higher COD loads with the correct small-volume method. Use the exact range-specific COD method; digestion equipment is supplied separately.

    • 0–15000 mg/L as O₂ · High-range dichromate adaptation
    • One pack of 25 pre-dosed vials; blank and QC affect sample yield
    • 150 °C / 120 min digestion; separate reactor required; ground-only DG

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

Measure higher COD loads with the correct small-volume method.

Keep high-strength sample work on the correct analytical path with HI93754C-25 high-range dichromate reagent vials. One pack supplies 25 pre-dosed vials for COD HR over 0–15000 mg/L as O₂. The method uses a 0.2 mL sample aliquot, so accurate small-volume delivery is central to the workflow; transferring a low- or medium-range 2 mL instruction to this formulation would be incorrect.

Official Hanna HI93754C-25 COD reagent vial packaging
Official Hanna HI93754C-25 packaging reference. Printed lot and expiration details are illustrative, not the supplied stock’s lot or expiry.

Match the refill to the complete method

Select HR when the expected oxygen demand and your validated method require the 0–15000 mg/L as O₂ range. This is the high-range dichromate formulation, not a universal EPA-approved product. Manufacturer discussion of standard EPA/ISO methods up to 1500 mg/L does not certify this high-range application for every permit or reporting program.

A refill for a complete digestion workflow

The pack contains 25 ready-to-use vials of HI93754C-0 reagent, not a photometer, reactor or starter kit. Pre-measured chemistry reduces the need to prepare bulk COD reagents or clean reaction glassware between determinations. Select the COD HR program on the compatible instrument and retain the exact method instructions with your laboratory SOP. Do not infer automatic barcode recognition from this catalog number.

Plan the blank before counting samples

A complete preparation starts with separate reagent vials for sample and blank: add 0.2 mL sample to one and 0.2 mL deionized water to the other, using the same reagent lot. The nominal 25-vial pack is not a promise of 25 reportable samples. The bench instrument manuals plan 24 samples with one blank; additional blanks, quality-control checks and repeats consume more vials. Follow the exact instrument method and your laboratory quality plan rather than assuming one blank can serve every batch.

Allow time for digestion and controlled cooling

All three documented instrument workflows require heated digestion at 150 °C for 120 minutes, followed by the prescribed cooling and mixing sequence. Have the separately supplied, existing HI839800-01 reactor available; the photometer does not replace the digestion block. Use the proper cooling rack, handle hot acid vials with the prescribed protective equipment, and never place hot vials in the photometer adapter. An oven or microwave is not a substitute for the specified reactor.

Check equipment and matrix together

Exact reagent-to-method compatibility is documented for HI97106, HI83314 and HI83399. Follow each model’s adapter installation and vial-handling instructions; generic holder fit is not established. Provide deionized water, an accurate 200 µL pipette with suitable tips, a cooling rack and SDS-prescribed PPE separately. A safety shield is strongly recommended. Homogenize samples containing settleable solids as the method directs. The instrument methods flag chloride above 20000 mg/L; assess dilution and the reporting calculation under the exact method rather than treating the reagent as immune to matrix interference.

Read the method reference in its reporting context

Hanna describes HI93754C-25 as an adaptation of the dichromate method for high-range COD. The instrument manuals also use EPA 410.4 adaptation language, but a reference heading is not universal regulatory approval of this high-range reagent or measurement. Confirm high-range applicability, any required dilution, quality controls and reporting acceptance with the governing method or permit authority.

Keep traceability and hazardous-waste handling visible

Store unused vials in their original packaging in a cool, dark place and follow the current label and SDS. Hanna identifies the lot and expiration date on the box and supplies a certificate of quality; no fixed remaining shelf life or supplied-lot expiry is promised here. These acid/dichromate reagents contain mercury(II) sulfate. Review the exact US component SDS before handling, use suitable protection and ventilation, and route used vials through regulated hazardous-waste handling with an authorized provider. Do not pour spent reagent down a drain. Dangerous Goods shipping is ground-only; this page does not authorize air transport.

Frequently Asked Questions

What exactly does one HI93754C-25 order contain?

One sellable pack of 25 pre-dosed high range COD reagent vials. It is a reagent refill only. The photometer, HI839800-01 reactor, deionized water, pipettes, tips, cooling rack, safety shield and protective equipment are not supplied by this listing. The catalog suffix describes the vial pack, not 25 guaranteed reportable sample results.

Which range and reporting units should I use?

Use the COD HR method over 0–15000 mg/L as O₂. Record results as chemical oxygen demand expressed as O₂, not as dissolved oxygen or elemental oxygen concentration. Choose the formulation and photometer program to match the expected sample range; another COD reagent is not an interchangeable refill just because its pack also has 25 vials.

Will these work with my Hanna instrument?

The exact reagent code is documented in the COD HR methods for HI97106, HI83314 and HI83399. Follow the adapter and vial-positioning instructions for your exact model, including the HI97106 COD adapter requirement. No physical vial diameter or universal holder compatibility is claimed. The instrument manuals in the document tab are method references, not standalone reagent manuals.

Why are 25 vials not necessarily 25 samples?

A required reagent blank uses one vial. The bench instrument manuals plan 24 sample tests from a 25-vial pack with one blank, while additional blanks, repeats and QC consume further vials. Blank and samples must use the same reagent lot. Although the manuals describe conditional blank reuse, follow the exact method and QC schedule and run a blank for each measurement set for improved accuracy; no universal reuse promise is made.

How much sample goes into a vial?

Add 0.2 mL sample to the sample reagent vial and 0.2 mL deionized water to a separate blank reagent vial, following the exact instrument method. This is 200 µL, not 2 mL. Use a calibrated small-volume pipette and suitable tips; do not carry LR/MR aliquot instructions into HR work.

Do I need a separate reactor?

Yes. The documented COD methods require digestion at 150 °C for 120 minutes in a suitable reactor, followed by the specified cooling sequence before zeroing and reading. Provide the HI839800-01 reactor separately. Neither the photometer nor this reagent pack performs digestion on its own. Follow the hot-vial precautions, cooling-rack procedure and safety-shield guidance in the method.

Does the method name guarantee regulatory acceptance?

No. This is a high-range dichromate adaptation, not a universally EPA-approved product. Standard-method references and the instrument manual’s EPA-adaptation heading do not establish acceptance of a 0–15000 mg/L result in every reporting program. Verify the applicable method range, dilution and QC requirements before reporting.

How should I store, ship and dispose of the vials?

Keep unused vials in their packaging in a cool, dark place and observe the supplied lot/expiry label and current HI93754C-0 US SDS. Shipping is Dangerous Goods, ground-only. The mixture includes acid, dichromate and mercury(II) sulfate; it is not harmless. Collect used vials as regulated hazardous waste and use an authorized waste provider under applicable requirements. Do not assume drain disposal or air shipping is permitted.

    Product Specifications

    SpecificationDetail
    Catalog numberHI93754C-25
    ParameterChemical oxygen demand (COD), as O₂
    Method / formulationHigh-range dichromate adaptation; mercury-containing
    Documented range0–15000 mg/L as O₂
    Pack contents25 pre-dosed reagent vials; one sellable pack
    Component identityHI93754C-0 reagent vial
    Documented instrumentsHI97106, HI83314, HI83399 — exact COD HR program
    Adapter requirementFollow exact model COD adapter and vial-handling instructions; no universal holder fit claimed
    Sample aliquot0.2 mL (200 µL) per sample reagent vial
    Blank preparation0.2 mL deionized water in a separate same-lot reagent vial
    Digestion150 °C for 120 minutes; cool according to instrument method before reading
    Sample-yield planningBench manuals plan 24 samples with one blank; additional QC/repeats/blanks reduce yield
    Required separatelyCompatible meter, HI839800-01 reactor, deionized water, accurate pipette/tips, cooling rack, PPE; safety shield strongly recommended
    Matrix / chlorideInstrument methods flag chloride above 20000 mg/L; follow exact method for dilution and matrix evaluation
    Storage and traceabilityOriginal packaging, cool and dark; follow lot/expiry label and current SDS; no fixed shelf life promised
    Transport / disposalDangerous Goods: ground-only. Used vials require regulated hazardous-waste handling.

    Ordering Information

    Catalog numberReagent pack
    HI93754C-25One pack of 25 pre-dosed COD reagent vials; sample yield depends on blank and QC use

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.