Apera T200-1 Turbidity Standards, 20/100/400/800 NTU (AI4204) Default Title Turbidity Calibration Standards Apera Instruments
Apera T200-1 Turbidity Standards, 20/100/400/800 NTU (AI4204) Default Title Turbidity Calibration Standards Apera Instruments

Apera T200-1 Turbidity Standards, 20/100/400/800 NTU (AI4204)

$149.00

    Four sealed nonzero standards for TN400 and TN480 calibration.

    • 20, 100, 400 and 800 NTU standards
    • For Apera TN400 and TN480 infrared meters
    • AMCO Clear polymer solutions; no dilution required
    • No 0 NTU vial included; never freeze

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / AI4204

Replace the four nonzero standards for TN400 and TN480.

T200-1 supplies four AMCO Clear polymer turbidity standards at 20, 100, 400 and 800 NTU for Apera TN400 and TN480 infrared meters. These are sealed, ready-to-use standards. A 0 NTU standard is not included, so plan the required zero-point reference separately.

Apera T200-1 four sealed turbidity standard vials labeled 20, 100, 400 and 800 NTU
Four nonzero standards are supplied; a 0 NTU vial is not included.

Why choose this accessory?

Four identified values

One vial each at 20, 100, 400 and 800 NTU supports the corresponding nonzero calibration points. Select the correct value in the meter calibration menu.

Sealed standards

The meter manuals distinguish these four nonzero standards from the refillable zero-point vial. Keep the nonzero vials sealed and replace them when expired.

No dilution step

Use the supplied standards at their labeled values. The product page describes ready-to-use polymer suspensions without dilution or routine resuspension.

Which existing setup does this accessory support?

CURRENT ITEM: AI4204

These are documented parent-meter workflows, not meters supplied with this accessory. Match the part number and required calibration or vial procedure.

Typical applications

Replace nonzero references

Refresh the nonzero standard set used by an existing TN400 or TN480. This is not a meter kit and does not supply a zero-point standard.

Choose calibration points

Follow the meter manual to choose two or more points that bracket the intended measurement range. Low-turbidity work may require 0 and 20 NTU, so this set alone does not cover that zero-point requirement.

Handle after storage

For polymer standards unused for a long time, the parent manuals direct two slow inversions followed by a 2 minute rest. Avoid vigorous shaking and bubbles; the separate zero-point solution has different handling instructions.

What this order supplies

Order detail Configuration
Manufacturer catalog AI4204
Blue Tiger SKU BTS-AI4204
Order unit One T200-1 set: 20, 100, 400 and 800 NTU
Not included 0 NTU standard, meter, empty sample vials, silicone oil and cleaning cloth
Selection note For TN400 and TN480 infrared meters; do not substitute solely by matching NTU numbers

Use the correct setup and care procedure.

Before ordering, confirm TN400 or TN480 and the required calibration values. T200-1 supplies four nonzero standards; arrange the zero-point reference separately when your procedure requires it.

Keep the vials sealed, never freeze them and follow the printed expiry. For safety or disposal questions, request the applicable product safety information and follow local requirements.

For warranty information or return authorization, contact Blue Tiger Scientific before sending any item. Do not assume that the parent meter warranty applies to a separately purchased accessory.

AI4204 buyer questions

Which values are included in T200-1?

The set contains one standard vial each at 20, 100, 400 and 800 NTU. All four values are nonzero.

Does this set include everything for zero-point calibration?

No. It does not include a 0 NTU standard. Follow your meter manual and obtain the required zero-point reference separately, especially for low-turbidity work.

Which meters is this set for?

Apera explicitly lists TN400 and TN480 infrared turbidity meters. Do not choose a standard for a different optical system solely because its NTU value matches.

Should I open the vials or dilute the contents?

No. The parent manuals direct users to keep the four nonzero standard vials sealed. Use each at its labeled value without dilution. Their handling is different from a refillable 0 NTU vial.

Should I shake the standards before calibration?

They are normally used directly. If unused for a long time, the parent manuals specify slowly inverting the polymer-standard vial twice and letting it stand for 2 minutes. Do not shake vigorously or introduce bubbles.

How should I store them, and when do they expire?

Keep them at room temperature and never freeze them. The parent manuals specify 5 to 30°C for calibration-solution storage. Follow the printed vial/lot expiry; the manufacturer photograph directs users to the vial bottom for the expiry date.

How do I clean the outside of a standard vial?

Keep it sealed. Follow the meter procedure for a clean exterior, using a small drop of silicone oil when needed, distributing it with a lint-free cloth and removing excess. Do not wash or refill the inside of a sealed nonzero standard vial.

Does using these standards make my meter EPA-compliant?

No. A standard-material approval does not establish compliance of an instrument, laboratory or analytical method. Confirm that your complete meter, procedure and reporting requirements match the applicable method.

    SpecificationDetail
    ManufacturerApera Instruments
    Catalog numberAI4204
    ModelT200-1
    Standard typeAMCO Clear polymer turbidity standards
    Values supplied20, 100, 400 and 800 NTU
    Quantity4 sealed standard vials
    Compatible metersApera TN400 and TN480 infrared turbidity meters
    0 NTU standardNot included
    PreparationReady to use at labeled value; no dilution
    StorageRoom temperature; parent manuals specify 5 to 30°C; never freeze
    ExpiryUse the printed vial/lot expiry; no remaining shelf life inferred from shipment date

    Ordering Information

    Order detailConfiguration
    Manufacturer catalogAI4204
    Blue Tiger SKUBTS-AI4204
    Order unitOne T200-1 set: 20, 100, 400 and 800 NTU
    Not included0 NTU standard, meter, empty sample vials, silicone oil and cleaning cloth
    Selection noteFor TN400 and TN480 infrared meters; do not substitute solely by matching NTU numbers

    Product Support

    Before ordering, confirm TN400 or TN480 and the required calibration values. T200-1 supplies four nonzero standards; arrange the zero-point reference separately when your procedure requires it.

    Keep the vials sealed, never freeze them and follow the printed expiry. For safety or disposal questions, request the applicable product safety information and follow local requirements.

    For warranty information or return authorization, contact Blue Tiger Scientific before sending any item. Do not assume that the parent meter warranty applies to a separately purchased accessory.