Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera LabSen 873 Refillable pH/Temperature Electrode for Organic Solvents, BNC/RCA pH Electrode Apera Instruments
Apera LabSen 873 Refillable pH/Temperature Electrode for Organic Solvents, BNC/RCA pH Electrode Apera Instruments
Apera LabSen 873 Refillable pH/Temperature Electrode for Organic Solvents, BNC/RCA pH Electrode Apera Instruments
Apera LabSen 873 Refillable pH/Temperature Electrode for Organic Solvents, BNC/RCA pH Electrode Apera Instruments
Apera LabSen 873 Refillable pH/Temperature Electrode for Organic Solvents, BNC/RCA pH Electrode Apera Instruments
Apera LabSen 873 Refillable pH/Temperature Electrode for Organic Solvents, BNC/RCA pH Electrode Apera Instruments
Apera LabSen 873 Refillable pH/Temperature Electrode for Organic Solvents, BNC/RCA pH Electrode Apera Instruments
Apera LabSen 873 Refillable pH/Temperature Electrode for Organic Solvents, BNC/RCA pH Electrode Apera Instruments
Apera LabSen 873 Refillable pH/Temperature Electrode for Organic Solvents, BNC/RCA pH Electrode Apera Instruments
Apera LabSen 873 Refillable pH/Temperature Electrode for Organic Solvents, BNC/RCA pH Electrode Apera Instruments
Apera LabSen 873 Refillable pH/Temperature Electrode for Organic Solvents, BNC/RCA pH Electrode Apera Instruments
Apera LabSen 873 Refillable pH/Temperature Electrode for Organic Solvents, BNC/RCA pH Electrode Apera Instruments
Apera LabSen 873 Refillable pH/Temperature Electrode for Organic Solvents, BNC/RCA pH Electrode Apera Instruments
Apera LabSen 873 Refillable pH/Temperature Electrode for Organic Solvents, BNC/RCA pH Electrode Apera Instruments

Apera LabSen 873 Refillable pH/Temperature Electrode for Organic Solvents, BNC/RCA

$385.00

    LabSen 873 combines a solvent-oriented double-junction reference, PHY glass membrane and a built-in temperature sensor. Its BNC/RCA connections suit compatible pH meters requiring both pH and 30 kΩ NTC temperature signals.

    • Current manufacturer PN: AI3249
    • pH range: 1–13 pH
    • Temperature range: 0–80°C / 32–176°F

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / LABSEN 873 / AI3249

pH in organic solvents.
Temperature in the same probe.

LabSen 873 combines a solvent-oriented double-junction reference, PHY glass membrane and a built-in temperature sensor. Its BNC/RCA connections suit compatible pH meters requiring both pH and 30 kΩ NTC temperature signals.

Manufacturer LabSen 873 product reference.
Manufacturer LabSen 873 product reference. Tap or click the image for a larger view.
Choose the right probe and supporting setupClick or tap to compare your optionsCompare below — click or tap here to close

Compare the selected product with the related listings below. Check the application, connection and order contents before choosing.

Linked cards open current store listings. Other cards compare configurations; they do not imply current storefront availability.

Apera double-junction structure diagram for the LabSen solvent electrode.
Apera double-junction structure diagram for the LabSen solvent electrode. Tap or click the image for a larger view.

A solvent-oriented
double junction.

The outer reference bridge uses 1M LiCl electrolyte and a movable sleeve junction. This construction is intended for water-miscible and water-immiscible organic solvents.

The method still matters: conventional aqueous pH buffers and solvent measurements are not automatically interchangeable reporting systems. Follow your solvent-specific analytical procedure.

PHY glass.
Protected internal contact.

The PHY membrane is designed to maintain the hydrated sensing layer in solvent applications. The blue gel inner electrolyte is intended to avoid internal air bubbles and preserve stable contact.

Handle the glass carefully and keep the sensing membrane and junction clean. Use the specified outer-bridge refill solution rather than substituting a general pH storage solution for every task.

Manufacturer comparison of blue gel and conventional inner electrolyte.
Manufacturer comparison of blue gel and conventional inner electrolyte. Tap or click the image for a larger view.
Apera dimensioned LabSen 873 electrode photograph.
Apera dimensioned LabSen 873 electrode photograph. Tap or click the image for a larger view.

Read the dimensions.
Match the sample vessel.

The current manufacturer dimensions are Ø12 × 130 mm. The operating window is 1–13 pH and 0–80°C; the sample and method must fit both limits.

The dimensioned manufacturer photo helps you check vessel access and immersion. It does not imply the connector or cable may be immersed.

Separate plugs.
One combined electrode.

BNC carries the pH signal and RCA carries the built-in 30 kΩ NTC temperature signal. Match both requirements to the meter; fitting the BNC plug alone is not enough to establish ATC compatibility.

For an electrode without built-in temperature, compare LabSen 871 and provide a separate temperature arrangement. The 873 keeps pH and temperature sensing in one electrode body.

LabSen 873 — Product dimensions and sensing detail
LabSen 873 — Product dimensions and sensing detail. Tap or click the image for a larger view.

What this order includes.

Order detail Configuration
Product LabSen 873
Manufacturer part number AI3249
Blue Tiger SKU BTS-AI3249
Order contents One LabSen 873 pH/temperature electrode. Compatible meter and replacement solutions are separate.

Check the fit
before ordering.

Specification Detail
Current manufacturer PN AI3249
pH range 1–13 pH
Temperature range 0–80°C / 32–176°F
Body / dimensions Lead-free glass; Ø12 × 130 mm
Membrane PHY glass
Reference / junction Ag/AgCl, double junction / movable sleeve
Outer electrolyte 1M LiCl
Inner electrolyte 3M KCl
Temperature sensor 30 kΩ NTC
Connector / cable BNC/RCA / 3 ft

Match the stated limits and configuration to your procedure. The Product Specifications tab repeats the order details for quick reference.

Compare related products.

Apera PH8500 Portable pH Meter Kit with 201T-F Electrode and USB Data Logging

Apera 602 Flexible Electrode Holder (AI2810)

LabSen 873 buyer questions

What is LabSen 873 designed for?

pH measurement in organic solvents and non-aqueous samples using an appropriate analytical method.

How is it different from LabSen 871?

The 873 includes a temperature sensor and BNC/RCA plugs; 871 is the BNC pH-only configuration.

Which refill solution does the outer bridge use?

The manufacturer specifies 1M LiCl for the outer bridge. Follow the electrode instructions for refilling and storage.

Does it include automatic temperature compensation?

It contains a 30 kΩ NTC temperature sensor. ATC also requires a compatible meter and RCA temperature input.

What are the measurement limits?

The manufacturer specifies 1–13 pH and 0–80°C for this electrode.

Will any BNC meter support both signals?

Not necessarily. The pH connection is BNC, while temperature also requires the correct RCA input and thermistor compatibility.

What is its current manufacturer PN?

Apera currently uses AI3249 for LabSen 873.

Can I use a general aqueous pH procedure in every solvent?

No. Solvent chemistry affects the electrode response and meaning of pH. Use the procedure and calibration appropriate to the sample.

Choose the configuration
that fits your work.

Review the order contents and the required host meter and application before ordering. Contact Blue Tiger Scientific if you need help matching the part.

Back to price and ordering ↑

    LabSen 873 specifications

    SpecificationDetail
    Current manufacturer PNAI3249
    pH range1–13 pH
    Temperature range0–80°C / 32–176°F
    Body / dimensionsLead-free glass; Ø12 × 130 mm
    MembranePHY glass
    Reference / junctionAg/AgCl, double junction / movable sleeve
    Outer electrolyte1M LiCl
    Inner electrolyte3M KCl
    Temperature sensor30 kΩ NTC
    Connector / cableBNC/RCA / 3 ft

    Ordering information

    SpecificationDetail
    Manufacturer part numberAI3249
    Blue Tiger SKUBTS-AI3249
    Order contentsOne LabSen 873 pH/temperature electrode. Compatible meter and replacement solutions are separate.

    Apera’s six-month limited electrode warranty covers qualifying defects in materials and workmanship from delivery, subject to its terms and exclusions.

    For setup, compatibility or troubleshooting support, contact Blue Tiger Scientific with the model, order number and a description of the issue.

    Contact Blue Tiger Scientific before returning a product. Return eligibility and instructions depend on the store’s applicable return policy and the condition of the item.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat