Record conductivity-derived readings with portable USB data handling. Includes 2301T-S conductivity/temperature electrode with the matching standards and carrying case.
Preparing Quote Cart. Your shopping cart stays unchanged.
The official kit page specifies the 2301T-S 8-pin conductivity/temperature electrode.
Swipe or use the arrows to browse.
APERA INSTRUMENTS / EC400S / AI422
EC400S combines conductivity with derived TDS, salinity and resistivity readings, plus timestamped recording and USB connectivity. Its separate 2301T-S conductivity/temperature electrode and supplied standards support a portable routine from calibration to reporting.
Choose AI422 when EC and its derived measurements need a recording workflow. Keep conductivity, TDS conversion and salinity/resistivity readouts distinct rather than treating them as independent chemical analyses.
500 groups
Meter memory
Timestamped manual/timed records
USB
Data workflow
Cable included; PC-Link options
IP57
Meter enclosure
Keep electrode connectors dry
The AI422 standard kit brings together the meter, its specified electrode and the matching calibration supplies. It is not a meter-only order.
EC400S meter, 2301T-S conductivity/temperature electrode, 84 µS/cm, 1413 µS/cm and 12.88 mS/cm conductivity standards, USB cable, carrying case and instructions.
2301T-S conductivity/temperature electrode
84 µS/cm, 1413 µS/cm and 12.88 mS/cm conductivity standards; 50 mL per listed bottle
USB cable, carrying case and instructions
START WITH THE SAMPLE AND THE WORKFLOW
Record conductivity and temperature with time information to compare suitable samples across a routine. A conductivity trend does not identify individual contaminants.
Use EC directly or derived TDS with a documented factor. Keep compensation settings and factor choice consistent when comparing results.
Retrieve saved records or use the USB/PC-Link path for connected measurements. Know which destination holds the data before starting a timed run.
The US manual specifies 500 stored groups for EC400S, manual or timed recording and USB output. TDS, salinity and resistivity derive from conductivity; conductivity calibration provides their measurement basis rather than separate independent calibration routines.
Use 1-4 point automatic conductivity calibration with 84 µS/cm, 1413 µS/cm, 12.88 mS/cm and optional 111.8 mS/cm recognition. The supplied kit includes the first three standards, not the fourth.
Choose the data workflow and parameter set, not the suffix alone. S does not mean a different standard probe or automatically better sample compatibility.
A measurement-focused EC/TDS kit. 1-4 point EC calibration. No supported measurement logger or USB function is documented for this standard model.
Timestamped memory, manual/timed recording and USB/PC-Link. 500 groups per US manual. Salinity/resistivity modes added. The standard supplied electrode model remains the same.
Offline field records stay in the meter’s documented memory. In a connected PC-Link session, live measurements are sent to software rather than saved in meter memory. Decide which workflow you need before starting a timed run.
Apera now links a browser-based PC-Link option alongside legacy Windows instructions. The current app uses Web Serial and names Chrome, Edge and Opera. USB drivers, browser permissions and local IT requirements can still affect setup.
Use the date, time, parameter, temperature and calibration information to support your records. These GLP-style functions do not by themselves establish an immutable audit trail, electronic signatures or regulated-software compliance.
Use suitable points from 84 µS/cm, 1413 µS/cm and 12.88 mS/cm. The recognized 111.8 mS/cm point is optional. Calibrate low to high and document the reference temperature, coefficient and any TDS factor.
Rinse before and after samples, avoid bubbles at the sensor and wait for stability. Keep connectors dry. The meter’s electronic range and compensation interval do not override the supplied electrode’s sample limits.
Keep pH glass in its KCl-based storage system, never pure water. For 2301T-S, follow its dedicated instructions for distilled/DI water in the cap. Do not rub sensing surfaces or improvise aggressive cleaning treatments.
For a dedicated pH routine with a separate 201T-S electrode. ORP needs a separately sold compatible electrode.
For conductivity and calculated TDS. S adds salinity/resistivity readouts and data functions.
For both pH and EC-derived workflows with two supplied probes, used in their appropriate modes.
A pocket tester can suit a different handling preference. Compare the measurement requirements, sensor and recording needs before switching formats; these are alternative instruments, not compatible plug-in accessories.
Alternative format: Apera EC60 pocket conductivity/TDS/salinity tester
Related workflow: Apera PC60 multi-parameter pocket tester
The kit includes EC400S, 2301T-S conductivity/temperature electrode, 84 µS/cm, 1413 µS/cm and 12.88 mS/cm standards, USB cable, carrying case and instructions. It requires four AA batteries.
The US 400S manual and Apera’s descriptive copy specify 500 groups. Stored records include timestamps, measurement units and temperature.
EC400S adds documented timestamped memory, timed recording and USB/PC-Link, plus salinity and resistivity readouts. Both use the standard 2301T-S conductivity electrode, and four-point EC calibration is not exclusive to S.
Meter conductivity extends to 200 mS/cm, calculated TDS to 100 g/L, salinity to 100 ppt and resistivity to 100 MΩ·cm. Electrode selection, sample chemistry and compensation determine whether the full meter range suits the method.
No. They are derived from the conductivity measurement. TDS factor is adjustable from 0.40 to 1.00, default 0.71. No separate composition-independent accuracy claim should be assumed for each derived value.
The kit supplies 84 µS/cm, 1413 µS/cm and 12.88 mS/cm. The meter also recognizes 111.8 mS/cm, but that fourth standard is separate. Calibrate low to high to limit carryover.
Apera’s current browser app uses Web Serial and specifies Chrome, Edge or Opera. Legacy Windows software also appears in the documentation. Check USB drivers, permissions and local IT requirements; do not assume Firefox/Safari or offline web-app operation.
The dedicated 2301T-S instructions specify distilled/DI water in the storage cap, not KCl pH-electrode solution. Rinse, remove bubbles and avoid rubbing the sensor. Follow the instructions supplied with the actual probe revision.
Review the EC400S specifications and supplied parts, then return to the price and ordering controls. Blue Tiger Scientific can help you compare the meter, probe and recording requirements for your application.
Meter ranges and compensation intervals describe the electronics, not an unrestricted operating range for the supplied electrode. Match the exact probe and sample conditions to the method.
APERA INSTRUMENTS, LLC warrants this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of TWO YEARS for the instrument from the delivery.
This limited warranty does NOT cover any issues due to:
Use the US meter manual and dedicated electrode instructions for the supplied kit. The English European brochure is supplemental regional literature. Each card opens a PDF in a new tab.
email us here: info@bluetigerscientific.com or live chat
Shipping and taxes calculated at checkout. Your quote list is separate.
Review your items, then tell Blue Tiger Scientific where your order is going. Your shopping cart stays unchanged.
International enquiries are welcome. Pricing, shipping availability, freight and any import requirements are confirmed manually.
Prices shown are for reference. We’ll confirm pricing, availability and shipping in your quote.
For eligible Accucold / Summit equipment. White glove and inside delivery are not included and are quoted separately. Shipping availability and final freight are confirmed with your quote, including Alaska, Hawaii and mixed-product requests.
Optional preferences only. Terms must be confirmed by Blue Tiger Scientific; no payment is collected and no terms are approved by this request.
Loading the security check…
* Required. Contact details and eligible quote-cart items will be submitted to Blue Tiger Scientific for this enquiry. No payment is collected.
Which would you like to open?
Review items for online purchase.
Review items and request a quote.
Your two carts stay separate. Nothing is moved or combined.