Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera EC400S Conductivity/TDS/Salinity Kit (AI422) Portable Multi-Parameter Meter Apera Instruments
Apera EC400S Conductivity/TDS/Salinity Kit (AI422) Portable Multi-Parameter Meter Apera Instruments
Apera EC400S Conductivity/TDS/Salinity Kit (AI422) Portable Multi-Parameter Meter Apera Instruments
Apera EC400S Conductivity/TDS/Salinity Kit (AI422) Portable Multi-Parameter Meter Apera Instruments
Apera EC400S Conductivity/TDS/Salinity Kit (AI422) Portable Multi-Parameter Meter Apera Instruments
Apera EC400S Conductivity/TDS/Salinity Kit (AI422) Portable Multi-Parameter Meter Apera Instruments
Apera EC400S Conductivity/TDS/Salinity Kit (AI422) Portable Multi-Parameter Meter Apera Instruments
Apera EC400S Conductivity/TDS/Salinity Kit (AI422) Portable Multi-Parameter Meter Apera Instruments

Apera EC400S Conductivity/TDS/Salinity Kit (AI422)

$445.00

    Record conductivity-derived readings with portable USB data handling. Includes 2301T-S conductivity/temperature electrode with the matching standards and carrying case.

    • EC accuracy: ±1.0% F.S. ±1 digit
    • 500 groups; manual/timed recording and USB cable
    • IP57 meter with separate 8-pin electrode connection

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / EC400S / AI422

Follow the solution.
Keep the measurement history.

EC400S combines conductivity with derived TDS, salinity and resistivity readings, plus timestamped recording and USB connectivity. Its separate 2301T-S conductivity/temperature electrode and supplied standards support a portable routine from calibration to reporting.

Choose AI422 when EC and its derived measurements need a recording workflow. Keep conductivity, TDS conversion and salinity/resistivity readouts distinct rather than treating them as independent chemical analyses.

Apera EC400S portable meter and standard supplied electrode
Apera EC400S · AI422 standard kit

500 groups

Meter memory

Timestamped manual/timed records

USB

Data workflow

Cable included; PC-Link options

IP57

Meter enclosure

Keep electrode connectors dry

Apera EC400S kit and calibration supplies
Standard-kit illustration. The text checklist identifies the included parts; optional electrodes and extra standards are separate.

Know what is in the case.

The AI422 standard kit brings together the meter, its specified electrode and the matching calibration supplies. It is not a meter-only order.

EC400S meter, 2301T-S conductivity/temperature electrode, 84 µS/cm, 1413 µS/cm and 12.88 mS/cm conductivity standards, USB cable, carrying case and instructions.

Specified electrode

2301T-S conductivity/temperature electrode

Calibration supplies

84 µS/cm, 1413 µS/cm and 12.88 mS/cm conductivity standards; 50 mL per listed bottle

Carry and connect

USB cable, carrying case and instructions

START WITH THE SAMPLE AND THE WORKFLOW

Where EC400S fits your work.

Process-water trends

Record conductivity and temperature with time information to compare suitable samples across a routine. A conductivity trend does not identify individual contaminants.

Nutrient and solution checks

Use EC directly or derived TDS with a documented factor. Keep compensation settings and factor choice consistent when comparing results.

Connected data work

Retrieve saved records or use the USB/PC-Link path for connected measurements. Know which destination holds the data before starting a timed run.

More useful records, with a known conversion basis.

The US manual specifies 500 stored groups for EC400S, manual or timed recording and USB output. TDS, salinity and resistivity derive from conductivity; conductivity calibration provides their measurement basis rather than separate independent calibration routines.

Use 1-4 point automatic conductivity calibration with 84 µS/cm, 1413 µS/cm, 12.88 mS/cm and optional 111.8 mS/cm recognition. The supplied kit includes the first three standards, not the fourth.

Apera 2301T-S conductivity cell sensing tip
Use the supplied probe for suitable samples and the correct 8-pin connector.

EC400 or EC400S: which do I need?

Choose the data workflow and parameter set, not the suffix alone. S does not mean a different standard probe or automatically better sample compatibility.

EC400

A measurement-focused EC/TDS kit. 1-4 point EC calibration. No supported measurement logger or USB function is documented for this standard model.

EC400S

Timestamped memory, manual/timed recording and USB/PC-Link. 500 groups per US manual. Salinity/resistivity modes added. The standard supplied electrode model remains the same.

Know where the record is stored.

Offline field records stay in the meter’s documented memory. In a connected PC-Link session, live measurements are sent to software rather than saved in meter memory. Decide which workflow you need before starting a timed run.

Apera now links a browser-based PC-Link option alongside legacy Windows instructions. The current app uses Web Serial and names Chrome, Edge and Opera. USB drivers, browser permissions and local IT requirements can still affect setup.

Use the date, time, parameter, temperature and calibration information to support your records. These GLP-style functions do not by themselves establish an immutable audit trail, electronic signatures or regulated-software compliance.

A repeatable routine, from setup to storage.

01

Calibrate the conductivity basis

Use suitable points from 84 µS/cm, 1413 µS/cm and 12.88 mS/cm. The recognized 111.8 mS/cm point is optional. Calibrate low to high and document the reference temperature, coefficient and any TDS factor.

02

Measure with the correct probe

Rinse before and after samples, avoid bubbles at the sensor and wait for stability. Keep connectors dry. The meter’s electronic range and compensation interval do not override the supplied electrode’s sample limits.

03

Store by electrode type

Keep pH glass in its KCl-based storage system, never pure water. For 2301T-S, follow its dedicated instructions for distilled/DI water in the cap. Do not rub sensing surfaces or improvise aggressive cleaning treatments.

Which 400-series meter do I need?

pH-focused · PH400 / PH400S

For a dedicated pH routine with a separate 201T-S electrode. ORP needs a separately sold compatible electrode.

EC-focused · EC400 / EC400S

For conductivity and calculated TDS. S adds salinity/resistivity readouts and data functions.

Combined · PC400 / PC400S

For both pH and EC-derived workflows with two supplied probes, used in their appropriate modes.

Need a different portable format?

A pocket tester can suit a different handling preference. Compare the measurement requirements, sensor and recording needs before switching formats; these are alternative instruments, not compatible plug-in accessories.

Alternative format: Apera EC60 pocket conductivity/TDS/salinity tester

Related workflow: Apera PC60 multi-parameter pocket tester

EC400S buyer questions

What comes in EC400S AI422?

The kit includes EC400S, 2301T-S conductivity/temperature electrode, 84 µS/cm, 1413 µS/cm and 12.88 mS/cm standards, USB cable, carrying case and instructions. It requires four AA batteries.

How many records does EC400S store?

The US 400S manual and Apera’s descriptive copy specify 500 groups. Stored records include timestamps, measurement units and temperature.

What does EC400S add over EC400?

EC400S adds documented timestamped memory, timed recording and USB/PC-Link, plus salinity and resistivity readouts. Both use the standard 2301T-S conductivity electrode, and four-point EC calibration is not exclusive to S.

What are the measurement ranges?

Meter conductivity extends to 200 mS/cm, calculated TDS to 100 g/L, salinity to 100 ppt and resistivity to 100 MΩ·cm. Electrode selection, sample chemistry and compensation determine whether the full meter range suits the method.

Are TDS, salinity and resistivity independent sensors?

No. They are derived from the conductivity measurement. TDS factor is adjustable from 0.40 to 1.00, default 0.71. No separate composition-independent accuracy claim should be assumed for each derived value.

Which conductivity standards are included?

The kit supplies 84 µS/cm, 1413 µS/cm and 12.88 mS/cm. The meter also recognizes 111.8 mS/cm, but that fourth standard is separate. Calibrate low to high to limit carryover.

Which PC-Link browser can I use?

Apera’s current browser app uses Web Serial and specifies Chrome, Edge or Opera. Legacy Windows software also appears in the documentation. Check USB drivers, permissions and local IT requirements; do not assume Firefox/Safari or offline web-app operation.

How do I store the conductivity electrode?

The dedicated 2301T-S instructions specify distilled/DI water in the storage cap, not KCl pH-electrode solution. Rinse, remove bubbles and avoid rubbing the sensor. Follow the instructions supplied with the actual probe revision.

Choose the workflow. Confirm the kit.

Review the EC400S specifications and supplied parts, then return to the price and ordering controls. Blue Tiger Scientific can help you compare the meter, probe and recording requirements for your application.

Back to price and ordering ↑
    SpecificationDetail
    BrandApera Instruments
    Model / catalog numberEC400S / AI422
    Supplied electrode2301T-S conductivity / temperature electrode
    Connector8-pin; use compatible electrode
    Meter enclosureIP57
    DisplayBacklit LCD; selected parameter and temperature
    Power requirement4 × 1.5 V AA batteries
    Measurement data memory500 groups, per US manual
    RecordingManual or timed saving
    USB / PC-LinkUSB cable included; legacy and browser PC-Link options
    Temperature resolution0.1°C
    Temperature accuracy±0.5°C ±1 digit

    Conductivity-derived measurements

    SpecificationDetail
    Meter conductivity range0-200 mS/cm; automatic ranges
    EC resolution by range0.01 / 0.1 / 1 µS/cm; 0.01 / 0.1 mS/cm
    EC accuracy±1.0% F.S. ±1 digit
    Calculated TDS range0-100 g/L
    TDS factorAdjustable 0.40-1.00; default 0.71
    EC calibrationAutomatic 1-4 points
    Supplied EC standards84 µS/cm; 1413 µS/cm; 12.88 mS/cm; 50 mL each
    Optional fourth EC standard111.8 mS/cm; not included
    Supplied cell constantK=1.0
    Supported cell constantsK=0.1 / 1 / 10; other cells are optional
    Meter EC compensation interval0-50°C, automatic/manual
    Reference temperature15-30°C adjustable; default 25°C
    Temperature coefficient0.00-9.99%/°C; default 2.00%/°C
    Derived salinity range0-100 ppt
    Derived resistivity range0-100 MΩ·cm

    Meter ranges and compensation intervals describe the electronics, not an unrestricted operating range for the supplied electrode. Match the exact probe and sample conditions to the method.

    Ordering Information

    Ordering detailIncluded configuration
    Catalog numberAI422
    Standard kitEC400S meter, 2301T-S conductivity / temperature electrode, 84 µS/cm, 1413 µS/cm and 12.88 mS/cm conductivity standards, USB cable, carrying case and instructions.
    Order unit1 kit

    Warranty Information

    APERA INSTRUMENTS, LLC warrants this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of TWO YEARS for the instrument from the delivery.

    This limited warranty does NOT cover any issues due to:

    • Accidental damage
    • Improper use
    • Normal wear and tear
    • Transportation
    • Storage
    • Failure to follow the product instructions
    • Unauthorized maintenance, modifications, combination or use with any products, materials, processes, systems or other matter
    • Unauthorized repair
    • External causes such as accidents, abuse, or other actions or events beyond our reasonable control.

    Apera EC400S documents

    Use the US meter manual and dedicated electrode instructions for the supplied kit. The English European brochure is supplemental regional literature. Each card opens a PDF in a new tab.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.