Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

So-Low DHK30-24MDP Manual Defrost Freezer – 23.5 Cu. Ft. | -15°C to -30°C Freezers So-Low
So-Low DHK30-24MDP Manual Defrost Freezer – 23.5 Cu. Ft. | -15°C to -30°C Freezers So-Low

So-Low DHK30-24MDP Manual Defrost Freezer – 23.5 Cu. Ft. | -15°C to -30°C

$4,700.00

    The So-Low DHK30-24MDP is a high-performance upright lab freezer engineered for precision, reliability, and long-term sample integrity. With manual defrost, digital controls, and a spacious 23.5 cu. ft. capacity, it’s trusted by clinical labs and research institutions nationwide for stable cold storage without disruptive frost cycles.

    • Manual defrost system ensures uninterrupted temperature stability

    • Digital alarm monitoring with USB data logging for compliance and control

    • UL listed and backed by a 2-year parts & labor warranty

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

So-Low DHK30-24MDP upright manual-defrost freezer, closed-door exterior view.

Actual DHK30-24MDP exterior. The guide below explains fit, monitoring and day-to-day planning.

DHK30-24MDP • LABORATORY COLD STORAGE

Space to organize.
Records to review.

Build your cold-storage workflow around a 23.5 cu. ft. upright cabinet with four adjustable shelves, a locking door and built-in temperature records. The So-Low DHK30-24MDP combines a −15°C to −30°C operating range with manual defrost and PDF downloads via USB.

Choose it when your materials require storage within this range and your lab can plan periodic defrost downtime. Use the fit, monitoring and delivery checks below to decide whether it suits your space and operating procedures.

23.5 cu. ft.

668 L cabinet capacity

−15 to −30°C

Published operating range

4 adjustable shelves

Flexible shelf placement

USB → PDF

Download temperature records

Will it fit your lab?

Measure the installation space and the full delivery route before ordering. Cabinet dimensions describe the freezer itself, not its shipping crate, door-open envelope or required ventilation space.

Exterior cabinet

34.75″ W × 37″ D × 76″ H
88 × 94 × 193 cm. Check doorways, turns, elevators and the final placement area.

Interior cabinet

27.5″ W × 28″ D × 51″ H
70 × 71 × 129 cm. Compare your box and rack dimensions with the usable layout, not cubic capacity alone.

Electrical supply

115 V / 60 Hz / single phase
Dedicated 15 A circuit with NEMA 5-15 connection. Plan the outlet location before delivery.

Leave ventilation and service access as required by the applicable installation instructions. Confirm clearance, door swing, shelf loading and rack fit before finalizing a layout; no rack-count capacity is implied.

What comes with this configuration?

Organize and secure

Four adjustable shelves, an insulated steel door with keyed lock, painted aluminum liner, four swivel casters and two leveling legs.

Monitor at the cabinet

Digital temperature display, min/max display and reset, high/low temperature alarms and adjustable-interval data logging with PDF download via USB.

Plan any extras separately

A 1″ access port and dry-contact alarm relay support external monitoring arrangements. Storage racks, boxes, independent probes and external notification equipment are not included in this listing.

An adjustable shelf layout is not a verified rack arrangement. Check the dimensions and load requirements of the containers you intend to use.

Temperature records without guesswork

The DHK30-24MDP records temperature at adjustable intervals and exports PDF files via USB. That gives your team a practical way to retrieve records rather than relying only on the current display reading.

The alarm set covers high/low temperature, door ajar, power failure, low battery, sensor failure and USB failure. Dry contacts provide a connection point for a suitable external alarm system; they are not a built-in Wi-Fi or text-messaging service.

Know what the battery protects

The backup battery powers the alarm only. It does not run the compressor or keep the cabinet cold during a power outage. Include separate backup-storage and response procedures in your lab plan.

Logging and alarms support your procedures. They do not, by themselves, establish regulatory compliance or validate storage conditions.

Temperature records workflow: record temperature, download via USB and review PDF files; battery backup powers alarms, not cooling.

Conceptual recordkeeping workflow. USB media and external notification equipment are not represented as included.

Manual defrost planning: transfer to backup storage, defrost and dry, restart to setpoint and return stored materials.

Planning overview, not a substitute for the applicable equipment manual. Backup storage must maintain the required conditions.

Manual defrost: a deliberate operating choice

Manual defrost avoids scheduled automatic-defrost warming cycles. It also means your team must plan when to remove accumulated ice and where to keep stored materials during maintenance.

Arrange suitable backup storage before defrosting. Follow the applicable equipment instructions for shutdown, thawing and drying, then restart and allow the freezer to return to the required setpoint before reloading.

Load with a plan

Let the empty freezer reach its setpoint before the first load. Introduce material gradually and allow temperature to recover between batches, following the manufacturer’s loading guidance.

Door openings, new loads and compressor operation can still affect temperature. Manual defrost is not a promise of uninterrupted or perfectly uniform conditions.

Which format matches your workflow?

A smaller freezer can save floor space, but capacity, shelf format and low-temperature capability change with the model. Here is a practical comparison with the smaller So-Low DHH20-20MDP.

DHK30-24MDP • This model

23.5 cu. ft. / 668 L
Published range: −15°C to −30°C.
34.75″ W × 37″ D × 76″ H.
Four adjustable shelves; USB PDF temperature records.

Consider it when you need the larger cabinet, adjustable shelving and a published lower limit of −30°C.

DHH20-20MDP • Smaller format

20 cu. ft. / 566 L
Published lower temperature limit: −25°C.
30.5″ W × 29.5″ D × 74.75″ H.
Six fixed shelves; manual defrost.

Consider the smaller footprint when −25°C is sufficient. Confirm current configuration and availability with us before selecting it.

These models are not interchangeable. Match the material’s required storage conditions and your lab’s procedures to the selected model; this comparison does not assert equivalent monitoring or performance.

Build a more organized cold-storage workflow

Related workflow • Freezer boxes

Explore MTC Bio freezer box formats for organizing tubes by project. Match the box footprint and height to your planned shelf or rack arrangement.

Related workflow • Cryogenic vials

Compare MTC Bio cryogenic vial formats for your sample-storage workflow. Select containers for the material, closure and storage conditions your procedure requires.

Related workflow items are sold separately. These links do not certify rack, shelf or container compatibility with this freezer.

Make the freight quote useful from the start

Provide your delivery ZIP or postal code, facility type and receiving details when requesting a quote. Tell us whether you have a loading dock and whether liftgate or inside-delivery service is needed so those requirements can be reviewed before shipment.

Before ordering

Confirm availability, manufacturer dispatch timing, transit estimates and the requested delivery service. Dispatch lead time is not the same as a guaranteed arrival date.

When it arrives

Inspect the shipment, ask the carrier to record visible damage or shortages on the delivery receipt, keep packaging and photographs, and contact Blue Tiger promptly with any issue.

Freight and extra services depend on the destination and order arrangements. The Additional Information tab explains receiving, return authorization and manufacturer-service routing.

DHK30-24MDP: buyer questions answered

What temperature range and capacity does the DHK30-24MDP offer?

So-Low publishes a −15°C to −30°C operating range and 23.5 cu. ft. (668 L) capacity for the DHK30-24MDP. Choose it only for materials whose required storage conditions fit that range and your facility’s procedures. It is not an ultra-low −80°C freezer.

What dimensions and electrical supply should I plan for?

The DHK30-24MDP cabinet measures 34.75″ W × 37″ D × 76″ H. It uses 115 V, 60 Hz, single-phase power on a dedicated 15 A circuit with a NEMA 5-15 connection. Allow the ventilation, door-opening and service space required by the applicable installation instructions; cabinet dimensions are not crate dimensions.

How many shelves are included, and will my freezer racks fit?

The DHK30-24MDP includes four adjustable shelves. Published interior dimensions are 27.5″ W × 28″ D × 51″ H. Compare your rack dimensions, required shelf spacing and loading limits before ordering. This listing does not claim a specific number of rack positions.

Can the DHK30-24MDP download temperature records?

Yes. The DHK30-24MDP provides adjustable-interval data logging and PDF downloads via USB. Check the applicable controller instructions for clock setup, logging settings and export steps. USB downloads are distinct from live cloud monitoring or automatic text alerts.

Does the backup battery keep the freezer cold during a power outage?

No. The DHK30-24MDP backup battery powers the alarm only, not refrigeration. Plan how staff will respond to an outage and where materials can be transferred if necessary. The dry-contact alarm relay can be used with a suitable external alarm system.

What does manual defrost require from my team?

Manual defrost requires planned downtime to remove accumulated ice. Transfer materials to appropriate backup storage, follow the applicable equipment procedure for defrosting and drying, then restart and verify the required temperature before reloading. Avoiding automatic-defrost cycles does not eliminate temperature changes from loading or door openings.

Is this freezer suitable for flammable materials or every vaccine and blood product?

Do not select the DHK30-24MDP as a flammable-material or explosion-proof freezer on the basis of this listing. Vaccine, blood-product and other sensitive-material requirements differ; match the exact storage requirements to manufacturer specifications and your validated procedures rather than relying on a general application label.

What delivery and warranty details should I confirm before ordering?

For the DHK30-24MDP, provide the destination and receiving requirements, including loading-dock access, liftgate and inside-delivery needs. Confirm freight, availability and timing before shipment. So-Low lists a two-year parts-and-labor manufacturer warranty; contact Blue Tiger for order assistance and coordination of manufacturer service. Return authorization is separate from warranty service.

    SpecificationDetail
    BrandSo-Low
    Model / manufacturer part numberDHK30-24MDP
    Capacity23.5 cu. ft. / 668 L
    Published temperature range−15°C to −30°C / 5°F to −22°F
    DefrostManual
    Exterior dimensions (W × D × H)34.75″ × 37″ × 76″ / 88 × 94 × 193 cm
    Interior dimensions (W × D × H)27.5″ × 28″ × 51″ / 70 × 71 × 129 cm
    Power supply115 V, 60 Hz, single phase
    Circuit requirementDedicated 15 A circuit
    Running current3.68 A
    NEMA configurationNEMA 5-15
    CertificationUL Listed
    Temperature controlDigital display
    Min/max temperatureDisplay and reset
    Temperature alarmsAudible high/low temperature alarm
    Additional alarmsDoor ajar, power failure, low battery, sensor failure, USB failure
    Data loggingAdjustable intervals
    Data downloadUSB; PDF format
    Backup batteryPowers alarm only; does not power refrigeration
    Alarm relayDry contacts
    CompressorHermetic
    DoorOne front hinged, insulated steel door; keyed lock
    Access port1″ diameter
    Included shelvesFour adjustable shelves
    Exterior finishPainted powder-coated steel
    InteriorPainted aluminum liner
    Mobility / levelingFour swivel casters; two leveling legs
    Manufacturer warrantyTwo years parts and labor
    Published shipping weight215 lb

    Ordering Information

    Ordering detailConfiguration
    Catalog numberDHK30-24MDP
    Blue Tiger SKUBTS-DHK30-24MDP
    Configuration115 V upright manual-defrost laboratory freezer
    Order unitOne freezer with four adjustable shelves
    Shipping weight215 lb; published manufacturer shipping weight

    Dimensions are cabinet dimensions, not shipping-crate dimensions. Confirm current configuration and installation requirements before final placement. Racks, boxes and external monitoring equipment are ordered separately.

    Shipping and receiving

    Orders are fulfilled through Blue Tiger Scientific’s suppliers. Contact Blue Tiger before ordering to confirm availability, freight arrangements and any liftgate or inside-delivery requirements; additional service charges may apply. Transit estimates do not include processing or manufacturer lead times. Shipping is FOB origin unless otherwise agreed. Inspect the shipment at delivery, have the carrier record visible damage or shortages on the delivery receipt, retain packaging and photographs, and promptly contact Blue Tiger with order details.

    Return authorization

    Return eligibility is subject to the product’s stated conditions, applicable manufacturer requirements and Blue Tiger Scientific’s refund policy. Contact info@bluetigerscientific.com before returning equipment. An approved RMA and designated return address are required; do not send returns to Blue Tiger’s business address. Authorized non-defective returns may incur restocking fees of up to 30%, shipping deductions and prepaid, insured return-shipping costs. International returns are not permitted.

    Manufacturer warranty and service

    So-Low lists a two-year parts-and-labor manufacturer warranty for the DHK30-24MDP. Warranty service is separate from return authorization. Contact Blue Tiger for order-related assistance and coordination with So-Low service. Have the model, serial number and problem description available. Obtain manufacturer service instructions before attempting repairs or replacing parts while under warranty.

    The series manual and general guides cover more than one configuration. Confirm your model and controller revision before following setup or service instructions; general guidance does not override the exact-model specifications.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.