(833) 928-4437
The So-Low DHK30-24MDP is a high-performance upright lab freezer engineered for precision, reliability, and long-term sample integrity. With manual defrost, digital controls, and a spacious 23.5 cu. ft. capacity, it’s trusted by clinical labs and research institutions nationwide for stable cold storage without disruptive frost cycles.
• Manual defrost system ensures uninterrupted temperature stability
• Digital alarm monitoring with USB data logging for compliance and control
• UL listed and backed by a 2-year parts & labor warranty
Preparing Quote Cart. Your shopping cart stays unchanged.
Actual DHK30-24MDP exterior. The guide below explains fit, monitoring and day-to-day planning.
DHK30-24MDP • LABORATORY COLD STORAGE
Build your cold-storage workflow around a 23.5 cu. ft. upright cabinet with four adjustable shelves, a locking door and built-in temperature records. The So-Low DHK30-24MDP combines a −15°C to −30°C operating range with manual defrost and PDF downloads via USB.
Choose it when your materials require storage within this range and your lab can plan periodic defrost downtime. Use the fit, monitoring and delivery checks below to decide whether it suits your space and operating procedures.
23.5 cu. ft.
668 L cabinet capacity
−15 to −30°C
Published operating range
4 adjustable shelves
Flexible shelf placement
USB → PDF
Download temperature records
Measure the installation space and the full delivery route before ordering. Cabinet dimensions describe the freezer itself, not its shipping crate, door-open envelope or required ventilation space.
34.75″ W × 37″ D × 76″ H88 × 94 × 193 cm. Check doorways, turns, elevators and the final placement area.
27.5″ W × 28″ D × 51″ H70 × 71 × 129 cm. Compare your box and rack dimensions with the usable layout, not cubic capacity alone.
115 V / 60 Hz / single phaseDedicated 15 A circuit with NEMA 5-15 connection. Plan the outlet location before delivery.
Leave ventilation and service access as required by the applicable installation instructions. Confirm clearance, door swing, shelf loading and rack fit before finalizing a layout; no rack-count capacity is implied.
Four adjustable shelves, an insulated steel door with keyed lock, painted aluminum liner, four swivel casters and two leveling legs.
Digital temperature display, min/max display and reset, high/low temperature alarms and adjustable-interval data logging with PDF download via USB.
A 1″ access port and dry-contact alarm relay support external monitoring arrangements. Storage racks, boxes, independent probes and external notification equipment are not included in this listing.
An adjustable shelf layout is not a verified rack arrangement. Check the dimensions and load requirements of the containers you intend to use.
The DHK30-24MDP records temperature at adjustable intervals and exports PDF files via USB. That gives your team a practical way to retrieve records rather than relying only on the current display reading.
The alarm set covers high/low temperature, door ajar, power failure, low battery, sensor failure and USB failure. Dry contacts provide a connection point for a suitable external alarm system; they are not a built-in Wi-Fi or text-messaging service.
The backup battery powers the alarm only. It does not run the compressor or keep the cabinet cold during a power outage. Include separate backup-storage and response procedures in your lab plan.
Logging and alarms support your procedures. They do not, by themselves, establish regulatory compliance or validate storage conditions.
Conceptual recordkeeping workflow. USB media and external notification equipment are not represented as included.
Planning overview, not a substitute for the applicable equipment manual. Backup storage must maintain the required conditions.
Manual defrost avoids scheduled automatic-defrost warming cycles. It also means your team must plan when to remove accumulated ice and where to keep stored materials during maintenance.
Arrange suitable backup storage before defrosting. Follow the applicable equipment instructions for shutdown, thawing and drying, then restart and allow the freezer to return to the required setpoint before reloading.
Let the empty freezer reach its setpoint before the first load. Introduce material gradually and allow temperature to recover between batches, following the manufacturer’s loading guidance.
Door openings, new loads and compressor operation can still affect temperature. Manual defrost is not a promise of uninterrupted or perfectly uniform conditions.
A smaller freezer can save floor space, but capacity, shelf format and low-temperature capability change with the model. Here is a practical comparison with the smaller So-Low DHH20-20MDP.
23.5 cu. ft. / 668 LPublished range: −15°C to −30°C.34.75″ W × 37″ D × 76″ H.Four adjustable shelves; USB PDF temperature records.Consider it when you need the larger cabinet, adjustable shelving and a published lower limit of −30°C.
20 cu. ft. / 566 LPublished lower temperature limit: −25°C.30.5″ W × 29.5″ D × 74.75″ H.Six fixed shelves; manual defrost.Consider the smaller footprint when −25°C is sufficient. Confirm current configuration and availability with us before selecting it.
These models are not interchangeable. Match the material’s required storage conditions and your lab’s procedures to the selected model; this comparison does not assert equivalent monitoring or performance.
Explore MTC Bio freezer box formats for organizing tubes by project. Match the box footprint and height to your planned shelf or rack arrangement.
Compare MTC Bio cryogenic vial formats for your sample-storage workflow. Select containers for the material, closure and storage conditions your procedure requires.
Related workflow items are sold separately. These links do not certify rack, shelf or container compatibility with this freezer.
Provide your delivery ZIP or postal code, facility type and receiving details when requesting a quote. Tell us whether you have a loading dock and whether liftgate or inside-delivery service is needed so those requirements can be reviewed before shipment.
Confirm availability, manufacturer dispatch timing, transit estimates and the requested delivery service. Dispatch lead time is not the same as a guaranteed arrival date.
Inspect the shipment, ask the carrier to record visible damage or shortages on the delivery receipt, keep packaging and photographs, and contact Blue Tiger promptly with any issue.
Freight and extra services depend on the destination and order arrangements. The Additional Information tab explains receiving, return authorization and manufacturer-service routing.
So-Low publishes a −15°C to −30°C operating range and 23.5 cu. ft. (668 L) capacity for the DHK30-24MDP. Choose it only for materials whose required storage conditions fit that range and your facility’s procedures. It is not an ultra-low −80°C freezer.
The DHK30-24MDP cabinet measures 34.75″ W × 37″ D × 76″ H. It uses 115 V, 60 Hz, single-phase power on a dedicated 15 A circuit with a NEMA 5-15 connection. Allow the ventilation, door-opening and service space required by the applicable installation instructions; cabinet dimensions are not crate dimensions.
The DHK30-24MDP includes four adjustable shelves. Published interior dimensions are 27.5″ W × 28″ D × 51″ H. Compare your rack dimensions, required shelf spacing and loading limits before ordering. This listing does not claim a specific number of rack positions.
Yes. The DHK30-24MDP provides adjustable-interval data logging and PDF downloads via USB. Check the applicable controller instructions for clock setup, logging settings and export steps. USB downloads are distinct from live cloud monitoring or automatic text alerts.
No. The DHK30-24MDP backup battery powers the alarm only, not refrigeration. Plan how staff will respond to an outage and where materials can be transferred if necessary. The dry-contact alarm relay can be used with a suitable external alarm system.
Manual defrost requires planned downtime to remove accumulated ice. Transfer materials to appropriate backup storage, follow the applicable equipment procedure for defrosting and drying, then restart and verify the required temperature before reloading. Avoiding automatic-defrost cycles does not eliminate temperature changes from loading or door openings.
Do not select the DHK30-24MDP as a flammable-material or explosion-proof freezer on the basis of this listing. Vaccine, blood-product and other sensitive-material requirements differ; match the exact storage requirements to manufacturer specifications and your validated procedures rather than relying on a general application label.
For the DHK30-24MDP, provide the destination and receiving requirements, including loading-dock access, liftgate and inside-delivery needs. Confirm freight, availability and timing before shipment. So-Low lists a two-year parts-and-labor manufacturer warranty; contact Blue Tiger for order assistance and coordination of manufacturer service. Return authorization is separate from warranty service.
Dimensions are cabinet dimensions, not shipping-crate dimensions. Confirm current configuration and installation requirements before final placement. Racks, boxes and external monitoring equipment are ordered separately.
Orders are fulfilled through Blue Tiger Scientific’s suppliers. Contact Blue Tiger before ordering to confirm availability, freight arrangements and any liftgate or inside-delivery requirements; additional service charges may apply. Transit estimates do not include processing or manufacturer lead times. Shipping is FOB origin unless otherwise agreed. Inspect the shipment at delivery, have the carrier record visible damage or shortages on the delivery receipt, retain packaging and photographs, and promptly contact Blue Tiger with order details.
Return eligibility is subject to the product’s stated conditions, applicable manufacturer requirements and Blue Tiger Scientific’s refund policy. Contact info@bluetigerscientific.com before returning equipment. An approved RMA and designated return address are required; do not send returns to Blue Tiger’s business address. Authorized non-defective returns may incur restocking fees of up to 30%, shipping deductions and prepaid, insured return-shipping costs. International returns are not permitted.
So-Low lists a two-year parts-and-labor manufacturer warranty for the DHK30-24MDP. Warranty service is separate from return authorization. Contact Blue Tiger for order-related assistance and coordination with So-Low service. Have the model, serial number and problem description available. Obtain manufacturer service instructions before attempting repairs or replacing parts while under warranty.
The series manual and general guides cover more than one configuration. Confirm your model and controller revision before following setup or service instructions; general guidance does not override the exact-model specifications.
email us here: info@bluetigerscientific.com or live chat
Shipping and taxes calculated at checkout. Your quote list is separate.
Review your items, then tell Blue Tiger Scientific where your order is going. Your shopping cart stays unchanged.
International enquiries are welcome. Pricing, shipping availability, freight and any import requirements are confirmed manually.
Prices shown are for reference. We’ll confirm pricing, availability and shipping in your quote.
For eligible Accucold / Summit equipment. White glove and inside delivery are not included and are quoted separately. Shipping availability and final freight are confirmed with your quote, including Alaska, Hawaii and mixed-product requests.
Optional preferences only. Terms must be confirmed by Blue Tiger Scientific; no payment is collected and no terms are approved by this request.
Loading the security check…
* Required. Contact details and eligible quote-cart items will be submitted to Blue Tiger Scientific for this enquiry. No payment is collected.
Which would you like to open?
Review items for online purchase.
Review items and request a quote.
Your two carts stay separate. Nothing is moved or combined.