    Check DEF/urea concentration and battery-acid specific gravity with a three-scale digital refractometer.

    • MDX-602; automatic temperature compensation
    • 3 application-specific scales
    • 1 instrument with case, pipet, battery and manual

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

Choose the scale for the sample

Check DEF/urea concentration and battery-acid specific gravity with a three-scale digital refractometer.

Heathrow Scientific Digital DEF/Battery Acid Refractometer | 48602 — Choose the scale for the sample
Digital refractometer family view. The model and screen values shown are illustrative; this item is the MDX-602.

Choose the scale for the sample

The MDX-602 serves two distinct maintenance measurements: DEF/urea concentration and battery-acid specific gravity, with refractive index as a third output. Its published applications include diesel-vehicle, agricultural and construction-equipment work. Select the sample-specific scale before measuring. A concentration reading is useful process information, not by itself certification that a vehicle meets an emissions requirement.

A repeatable small-sample reading sequence

The matching manual calls for a daily zero check with clean distilled water, a clean dry sample well and a closed prism cover. For a reading, place 4–5 drops in the well, close the cover and press READ. The instrument supports individual readings and a 15-reading continuous loop. Allow a sample at a different temperature to acclimate as described in the manual; automatic temperature compensation is not a reason to skip that step.

Heathrow Scientific Digital DEF/Battery Acid Refractometer | 48602 — A repeatable small-sample reading sequence
Digital refractometer family view. The model and screen values shown are illustrative; this item is the MDX-602.

Prepare the instrument for the next sample

The stainless-steel prism well and removable grip/cover support access between readings. Follow the model manual’s care instructions, especially after corrosive or acidic samples, and avoid getting sample on the plastic housing. The detecting unit is rated IP67 and the remainder IP65; keep those two ratings distinct rather than describing the whole device as suitable for immersion. A hard-shell protective case, disposable pipet, AAA battery and manual accompany the instrument.

Confirm the order unit

48602 — 1 Each.

Related choices for your workflow

Heathrow Scientific Handheld Urea Refractometer for DEF & AdBlue

Compare a dedicated handheld urea instrument when DEF is the sole application.

Heathrow Scientific Digital Coolant Refractometer | 48603

Use the coolant model when the primary task is glycol coolant rather than DEF; choose by the published fluid-specific scales.

Frequently Asked Questions

Which model is supplied?

MDX-602. Use the model number and application scales to select your instrument, rather than the example reading on the display.

What is the main application scale?

DEF/urea: 0.0–51%; resolution 0.1%; accuracy ±0.2%.

Does it have refractive index?

Yes. The range is 1.3330–1.4200 nD. If your method requires a particular resolution, confirm that requirement for the MDX-602 before ordering.

How is it zeroed?

Use clean distilled water and the ZERO sequence in the matching manual, with the prism cover closed. The manual recommends a daily zero check.

Can it take repeated readings?

Yes. It supports single readings and a 15-reading continuous loop.

Is the entire instrument IP67?

No. The detecting unit is IP67; the remainder is IP65. Follow the manual for care and exposure limits.

What comes with the instrument?

A rubber grip and prism cover, hard-shell protective case, disposable pipet, AAA battery and instruction manual.

    SpecificationDetail
    BrandHeathrow Scientific
    Product lineVEE GEE
    ModelMDX-602
    DEF/urea0.0–51%; resolution 0.1%; accuracy ±0.2%
    Refractive index1.3330–1.4200 nD; accuracy ±0.0003; confirm resolution
    Battery acid1.000–1.500 s.g.; resolution 0.001; accuracy ±0.005
    Temperature compensationAutomatic
    Reading modesSingle or 15-reading continuous loop
    Protection ratingsIP67 detecting unit; IP65 remainder
    PowerAAA battery included
    Manufacturer warranty1 year

    Ordering Information

    Cat. No.DescriptionPack
    48602Digital DEF/Battery Acid Refractometer | 486021 Each

    Heathrow Scientific: Shipping & Return Policy

    At Blue Tiger Scientific, we're proud to offer a wide range of authentic Heathrow Scientific products. Please review the following policies, which apply to all Heathrow Scientific purchases made through our store. Remember, all return requests must be initiated directly with Blue Tiger Scientific.

    Shipping Policy

    Orders for Heathrow Scientific products are fulfilled and shipped straight from Heathrow Scientific's facilities, primarily utilizing reliable carriers like FedEx or UPS. FedEx Ground is the standard shipping method for all orders.


    Heathrow Scientific ships only to residential or business addresses within the United States. We cannot ship to P.O. Boxes.


    Orders placed outside of regular business hours, on weekends, or during holidays will be processed on the next business day, subject to product availability and carrier schedules.


    Delivery times can vary based on the specific product's availability, the overall size of your order, and current carrier logistics.


    Once your order has shipped, Blue Tiger Scientific and Heathrow Scientific are not responsible for unforeseen carrier delays, disruptions due to weather, or other delivery issues beyond our control.


    All shipments are processed on an EX-WORKS (EXW) basis from Heathrow Scientific’s facility. Risk of loss passes to the customer once the product is picked up by the carrier.

    Return Policy

    Should you need to return a Heathrow Scientific product, you must start the process with Blue Tiger Scientific. We will then work directly with Heathrow Scientific to facilitate your return, ensuring you obtain the necessary Return Goods Authorization (RGA) number.

    For domestic orders, products must be returned within 30 days of the order shipment date.

    All returns must include a valid RGA number obtained from Blue Tiger Scientific. If the product isn't received within the stipulated period, the RGA number will be voided. Any item received without a valid RGA number will be returned to the sender.

    Damaged or Missing Goods

    To ensure eligibility for a replacement or refund, all claims for damaged or missing items must be reported within 24 hours of delivery. Failure to report within this timeframe may void your claim due to carrier claim limitations.

    Returns Due to Customer Error or Change of Mind

    If you ordered the wrong product or simply changed your mind:

    The refund is the purchase price less a 20% restocking fee and less the original shipping costs. The product must be unused, in its original, unopened packaging and in resalable condition.

    Once Heathrow Scientific receives the returned product and verifies its condition, a credit will typically be issued to your original payment method within approximately 3 weeks.

    Non-Returnable Items

    Please note the following are non-returnable under any circumstances:

    Items missing accessories, manuals, or packaging will be rejected.

    Products classified as hazardous cannot be returned. Certain items are made to order and are not eligible for return or refund.

    Warranty Information & Registration

    All warranty claims and product registration are handled directly by Heathrow Scientific. Product-specific warranty note: For this product, the manufacturer publishes a warranty period of 1 year. Coverage, exclusions and service follow the applicable manufacturer terms; contact Blue Tiger Scientific to coordinate assessment. Retain proof of purchase.

    For warranty details or to register your product, visit Heathrow Scientific’s Warranty Information & Registration page.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.