Acid Hydrolyzable Phosphorus for the right phosphorus fraction. Choose acid-hydrolyzable phosphorus when you need free orthophosphate plus condensed inorganic forms, not reactive-only or total phosphorus.
Preparing Quote Cart. Your shopping cart stays unchanged.
Select the Acid Hydrolyzable Phosphorus 16 mm method.
Use the phosphorus method at 150 °C for 30 minutes; reactor sold separately.
Swipe or use the arrows to browse.
Choose acid-hydrolyzable phosphorus when you need free orthophosphate plus condensed inorganic forms, not reactive-only or total phosphorus.
Reactive LR measures reactive orthophosphate without heat. Acid hydrolyzable includes free and condensed inorganic forms after heating. Total LR uses persulfate digestion for a broader total-phosphorus method.
Acid Hydrolyzable Phosphorus: 0.00–1.60 mg/L as P; 0.01 mg/L resolution on HI83314 and HI83399.
Add 5 mL sample to an HI93758V-0AH vial, cap and invert several times to mix. Heat for 30 minutes at 150 °C, then cool to room temperature in a rack. Add 2.0 mL HI93758B-0 NaOH solution and invert gently to mix. Clean the vial and zero it before adding one HI93758-0 phosphorus reagent packet. Shake gently for 2 minutes until the powder dissolves, wait 3 minutes, clean the vial and read. This acid-hydrolysis procedure does not add persulfate.
Use an HI83314 or HI83399 with 16 mm adapter, a 150 °C reactor such as the separately sold HI839800-01, cooling rack, accurate 5 mL and 2 mL dosing tools, wipes and SDS-directed PPE. The manual strongly recommends the HI740217 safety shield; check whether yours is already supplied.
One pack provides 50 nominal tests. The acid-hydrolyzable method uses HI93758V-0AH vials, HI93758B-0 NaOH solution and HI93758-0 phosphorus reagent. Use the component codes on the supplied instructions when selecting replacement reagents and safety data sheets.
Read the matching current component SDS and instrument instructions before use. Never substitute an oven or microwave for the reactor: leaking samples can create a corrosive and potentially explosive atmosphere. Handle hot vials carefully. Store unused vials in their packaging in a cool, dark place. Check the manual for interference and waste requirements. Hanna classifies this offer as dangerous goods and states such goods can ship only by ground.
Free orthophosphate and condensed inorganic phosphates, rather than the reactive-only or total fraction.
0.00–1.60 mg/L as phosphorus (P), with 0.01 mg/L resolution on HI83314 and HI83399.
Use the HI83314 or HI83399 named phosphorus method with the 16 mm vial adapter. Select the correct phosphorus fraction on the instrument and follow its full procedure.
One pack provides 50 nominal tests. Plan repeat measurements, quality-control checks and sample preparation separately when estimating your testing needs.
Yes. The instrument manuals specify 150 °C for 30 minutes; use a suitable reactor and cooling rack, sold separately.
No. This procedure uses the HI93758V-0AH acid-hydrolysis vial and heat, followed by HI93758B-0 NaOH and HI93758-0 color reagent. PERSULFATE/P belongs to the separate total-phosphorus workflow, not this acid-hydrolyzable procedure.
The instrument Chem Frm function converts the reported value to phosphate or phosphorus pentoxide. Conversion changes the expression basis, not the measured fraction; the listed numeric range is as P.
Arsenate must be absent; silica above 50 mg/L, sulfide, and substantial turbidity or suspended matter can interfere. Follow the instrument manual for sample treatment, wear SDS-directed PPE, and use appropriate chemical waste handling.
At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.
Instrument manuals covering the named reagent methods, not standalone reagent instructions.
Check the SDS for the supplied lot before handling.
email us here: info@bluetigerscientific.com or live chat
Shipping and taxes calculated at checkout. Your quote list is separate.
Review your items, then tell Blue Tiger Scientific where your order is going. Your shopping cart stays unchanged.
International enquiries are welcome. Pricing, shipping availability, freight and any import requirements are confirmed manually.
Prices shown are for reference. We’ll confirm pricing, availability and shipping in your quote.
For eligible Accucold / Summit equipment. White glove and inside delivery are not included and are quoted separately. Shipping availability and final freight are confirmed with your quote, including Alaska, Hawaii and mixed-product requests.
Optional preferences only. Terms must be confirmed by Blue Tiger Scientific; no payment is collected and no terms are approved by this request.
Loading the security check…
* Required. Contact details and eligible quote-cart items will be submitted to Blue Tiger Scientific for this enquiry. No payment is collected.
Which would you like to open?
Review items for online purchase.
Review items and request a quote.
Your two carts stay separate. Nothing is moved or combined.