Keep ozone checks supplied—and chlorine corrections clear.
Refill the ozone workflow on your Hanna HI83326 pool and spa photometer with pre-measured HI93757-0 powder reagent. Choose HI93757-01, labeled 100 tests, or HI93757-03, labeled 300 tests. Both use the same DPD ozone chemistry; neither pack is a meter kit or a chlorine test. The right pack choice starts with how you actually measure your samples, including any chlorine correction.
Official Hanna ozone reagent reference photo. Printed lot/expiry details are illustrative, not the lot or expiration of supplied stock. The two nominal pack sizes use the same reagent chemistry.
Match the refill to the complete method
HI83326 measures 0.00–2.00 mg/L as ozone (O3) by the colorimetric DPD method. HI83300 and HI83399 also document this ozone reagent procedure. Glycine is a separate optional reagent only for samples with chlorine present or suspected—not a routine requirement for chlorine-free water.
A refill matched to an established method
Use the reagent code and the instrument’s Ozone method together. The reaction develops the color used by the photometer to report ozone in mg/L as O3. Selecting a larger nominal test pack changes the refill capacity, not the method, range or reporting basis. This is ozone analysis, not dissolved oxygen or an oxygen-scavenger assay.
Chlorine-free samples: keep the sequence straightforward
On HI83326, zero with 10 mL unreacted sample in the capped and stoppered cuvette. Add one HI93757-0 packet, replace the stopper and cap, and shake gently for 20 seconds. Use the instrument timer or wait 2 minutes before reading. No glycine addition is called for in this standard chlorine-free procedure.
If chlorine is present, use both readings
When free or total chlorine is present or suspected, first perform the standard ozone measurement and record A. On a fresh 10 mL sample, zero again, add one HI93703-52-0 glycine packet and dissolve completely, then add one HI93757-0 ozone packet. Shake gently for 20 seconds and wait 2 minutes before reading B. Report ozone as A − B, not B alone.
Choose capacity for the whole workflow
The 100-test and 300-test descriptions are Hanna’s nominal ozone reagent test labels, not promises of 100 or 300 chlorine-corrected results. Each corrected result uses two ozone-reagent portions plus one glycine packet. The labels do not establish an exact physical packet inventory; plan the workload around the complete method and the supplied stock.
Check the sample before interpreting the number
Bromine, chlorine dioxide and iodine interfere. Above 500 mg/L hardness as CaCO3, the HI83326 manual calls for approximately 2 minutes of shaking after powder addition. Alkalinity above 250 mg/L as CaCO3 can prevent full color development or cause fading; follow the manual’s dilute-HCl neutralization guidance.
What to have ready separately
Supply the compatible photometer, clean cuvettes, caps and stoppers separately. If the sample needs chlorine correction, obtain HI93703-52 glycine separately as well. Instrument-verification standards are not replacements for ozone sample reagent. Keep optical surfaces clean and follow the exact-model manual rather than transferring settings from another parameter.
Traceability and practical stock planning
One order quantity means one selected nominal test pack. Check the lot and expiry markings on received reagents, include repeats and quality-control work in your consumption plan, and do not use the date printed in a reference photograph as a stock promise. Read the component US Safety Data Sheet before handling. The linked instrument manuals are method references, not standalone reagent manuals.
Frequently Asked Questions
Which pack should I choose?
HI93757-01 is labeled 100 tests and HI93757-03 is labeled 300 tests. Choose by workload, correction requirements and marked expiry dates. Both cover the same ozone method and measuring range.
Will the 100-test pack give 100 chlorine-corrected results?
The 100-test and 300-test descriptions are Hanna’s nominal ozone reagent test labels, not promises of 100 or 300 chlorine-corrected results. Each corrected result uses two ozone-reagent portions plus one glycine packet. The labels do not establish an exact physical packet inventory; plan the workload around the complete method and the supplied stock.
Do I need glycine for every ozone test?
No. HI93703-52 is optional and separate. Use the additional procedure only when free or total chlorine is present or suspected; it is not part of the standard chlorine-free sequence.
How is a chlorine-containing result calculated?
When free or total chlorine is present or suspected, first perform the standard ozone measurement and record A. On a fresh 10 mL sample, zero again, add one HI93703-52-0 glycine packet and dissolve completely, then add one HI93757-0 ozone packet. Shake gently for 20 seconds and wait 2 minutes before reading B. Report ozone as A − B, not B alone.
Which instruments are documented?
HI83326 is the primary method reference here, at 0.00–2.00 mg/L as O3. HI83300 and HI83399 also document HI93757-0 for ozone. Select the exact-model Ozone method and follow its manual.
How long do I mix and wait?
For the normal HI83326 procedure, shake gently for 20 seconds after ozone reagent addition, then use the timer or wait 2 minutes before reading. For the additional reading, dissolve glycine completely before adding ozone reagent. The hardness precaution can require longer shaking.
What sample interferences matter?
Bromine, chlorine dioxide and iodine interfere. Above 500 mg/L hardness as CaCO3, the HI83326 manual calls for approximately 2 minutes of shaking after powder addition. Alkalinity above 250 mg/L as CaCO3 can prevent full color development or cause fading; follow the manual’s dilute-HCl neutralization guidance.
Is this a complete photometer kit?
No. It is the selected ozone reagent pack only. The instrument, cuvettes, caps, stoppers, verification standards and conditional glycine are separate. The manufacturer’s nominal test count does not specify the exact physical packet inventory.