Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Hanna HI93757 Ozone Reagents, 100/300 Tests Photometer Reagents Hanna Instruments
Hanna HI93757 Ozone Reagents, 100/300 Tests Photometer Reagents Hanna Instruments

Hanna HI93757 Ozone Reagents, 100/300 Tests

$43.99

    Keep ozone checks supplied—and chlorine corrections clear. Keep the matched reagent refill ready for your established method.

    • 100 or 300 nominal ozone tests; same DPD method
    • HI83326: 0.00–2.00 mg/L as O3
    • Glycine separate and conditional; A − B correction uses two ozone portions

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Keep ozone checks supplied—and chlorine corrections clear.

Refill the ozone workflow on your Hanna HI83326 pool and spa photometer with pre-measured HI93757-0 powder reagent. Choose HI93757-01, labeled 100 tests, or HI93757-03, labeled 300 tests. Both use the same DPD ozone chemistry; neither pack is a meter kit or a chlorine test. The right pack choice starts with how you actually measure your samples, including any chlorine correction.

Official Hanna HI93757 reagent reference packaging
Official Hanna ozone reagent reference photo. Printed lot/expiry details are illustrative, not the lot or expiration of supplied stock. The two nominal pack sizes use the same reagent chemistry.

Match the refill to the complete method

HI83326 measures 0.00–2.00 mg/L as ozone (O3) by the colorimetric DPD method. HI83300 and HI83399 also document this ozone reagent procedure. Glycine is a separate optional reagent only for samples with chlorine present or suspected—not a routine requirement for chlorine-free water.

A refill matched to an established method

Use the reagent code and the instrument’s Ozone method together. The reaction develops the color used by the photometer to report ozone in mg/L as O3. Selecting a larger nominal test pack changes the refill capacity, not the method, range or reporting basis. This is ozone analysis, not dissolved oxygen or an oxygen-scavenger assay.

Chlorine-free samples: keep the sequence straightforward

On HI83326, zero with 10 mL unreacted sample in the capped and stoppered cuvette. Add one HI93757-0 packet, replace the stopper and cap, and shake gently for 20 seconds. Use the instrument timer or wait 2 minutes before reading. No glycine addition is called for in this standard chlorine-free procedure.

If chlorine is present, use both readings

When free or total chlorine is present or suspected, first perform the standard ozone measurement and record A. On a fresh 10 mL sample, zero again, add one HI93703-52-0 glycine packet and dissolve completely, then add one HI93757-0 ozone packet. Shake gently for 20 seconds and wait 2 minutes before reading B. Report ozone as A − B, not B alone.

Choose capacity for the whole workflow

The 100-test and 300-test descriptions are Hanna’s nominal ozone reagent test labels, not promises of 100 or 300 chlorine-corrected results. Each corrected result uses two ozone-reagent portions plus one glycine packet. The labels do not establish an exact physical packet inventory; plan the workload around the complete method and the supplied stock.

Check the sample before interpreting the number

Bromine, chlorine dioxide and iodine interfere. Above 500 mg/L hardness as CaCO3, the HI83326 manual calls for approximately 2 minutes of shaking after powder addition. Alkalinity above 250 mg/L as CaCO3 can prevent full color development or cause fading; follow the manual’s dilute-HCl neutralization guidance.

What to have ready separately

Supply the compatible photometer, clean cuvettes, caps and stoppers separately. If the sample needs chlorine correction, obtain HI93703-52 glycine separately as well. Instrument-verification standards are not replacements for ozone sample reagent. Keep optical surfaces clean and follow the exact-model manual rather than transferring settings from another parameter.

Traceability and practical stock planning

One order quantity means one selected nominal test pack. Check the lot and expiry markings on received reagents, include repeats and quality-control work in your consumption plan, and do not use the date printed in a reference photograph as a stock promise. Read the component US Safety Data Sheet before handling. The linked instrument manuals are method references, not standalone reagent manuals.

Frequently Asked Questions

Which pack should I choose?

HI93757-01 is labeled 100 tests and HI93757-03 is labeled 300 tests. Choose by workload, correction requirements and marked expiry dates. Both cover the same ozone method and measuring range.

Will the 100-test pack give 100 chlorine-corrected results?

The 100-test and 300-test descriptions are Hanna’s nominal ozone reagent test labels, not promises of 100 or 300 chlorine-corrected results. Each corrected result uses two ozone-reagent portions plus one glycine packet. The labels do not establish an exact physical packet inventory; plan the workload around the complete method and the supplied stock.

Do I need glycine for every ozone test?

No. HI93703-52 is optional and separate. Use the additional procedure only when free or total chlorine is present or suspected; it is not part of the standard chlorine-free sequence.

How is a chlorine-containing result calculated?

When free or total chlorine is present or suspected, first perform the standard ozone measurement and record A. On a fresh 10 mL sample, zero again, add one HI93703-52-0 glycine packet and dissolve completely, then add one HI93757-0 ozone packet. Shake gently for 20 seconds and wait 2 minutes before reading B. Report ozone as A − B, not B alone.

Which instruments are documented?

HI83326 is the primary method reference here, at 0.00–2.00 mg/L as O3. HI83300 and HI83399 also document HI93757-0 for ozone. Select the exact-model Ozone method and follow its manual.

How long do I mix and wait?

For the normal HI83326 procedure, shake gently for 20 seconds after ozone reagent addition, then use the timer or wait 2 minutes before reading. For the additional reading, dissolve glycine completely before adding ozone reagent. The hardness precaution can require longer shaking.

What sample interferences matter?

Bromine, chlorine dioxide and iodine interfere. Above 500 mg/L hardness as CaCO3, the HI83326 manual calls for approximately 2 minutes of shaking after powder addition. Alkalinity above 250 mg/L as CaCO3 can prevent full color development or cause fading; follow the manual’s dilute-HCl neutralization guidance.

Is this a complete photometer kit?

No. It is the selected ozone reagent pack only. The instrument, cuvettes, caps, stoppers, verification standards and conditional glycine are separate. The manufacturer’s nominal test count does not specify the exact physical packet inventory.

    Product Specifications

    SpecificationDetail
    ParameterOzone, O3
    MethodColorimetric DPD
    Primary instrument and rangeHI83326: 0.00–2.00 mg/L as O3
    Other documented ozone instrumentsHI83300; HI83399 — use exact-model method
    Reagent codeHI93757-0, pre-measured powder
    Chlorine-free doseOne ozone packet per 10 mL sample
    Normal HI83326 timingShake gently 20 seconds; wait 2 minutes/read timer
    Conditional helperHI93703-52 glycine, separate; only if chlorine present or suspected
    Corrected resultA − B; two ozone portions plus one glycine packet
    Capacity interpretationNominal 100/300 test labels; not 100/300 chlorine-corrected results
    Other matrix precautionsBromine, chlorine dioxide and iodine interfere. Above 500 mg/L hardness as CaCO3, the HI83326 manual calls for approximately 2 minutes of shaking after powder addition. Alkalinity above 250 mg/L as CaCO3 can prevent full color development or cause fading; follow the manual’s dilute-HCl neutralization guidance.

    Ordering Information

    Catalog numberReagent pack
    HI93757-01100 tests — nominal ozone label; corrected results require two ozone portions plus separate glycine
    HI93757-03300 tests — nominal ozone label; corrected results require two ozone portions plus separate glycine

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.