Hanna HI93703-52 Glycine Powder Reagents, 100 Tests Default Title Photometer Reagents Hanna Instruments
Hanna HI93703-52 Glycine Powder Reagents, 100 Tests Default Title Photometer Reagents Hanna Instruments

Hanna HI93703-52 Glycine Powder Reagents, 100 Tests

$30.79

    Keep the conditional ozone correction ready. Optional glycine refill for the complete ozone correction workflow.

    • 100-test glycine helper pack; single orderable SKU
    • Only for ozone samples with chlorine present or suspected
    • Separate ozone reagent required; corrected result is A − B

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

Keep the conditional ozone correction ready.

Hanna HI93703-52 supplies pre-measured glycine powder for the additional ozone procedure when chlorine is present or suspected. The 100-test pack is a separate optional helper for compatible benchtop photometers—not a standalone ozone assay and not a routine addition to chlorine-free samples. Keep it available where chlorine interference is a realistic part of the testing workflow, alongside the separate HI93757 ozone reagents.

Official Hanna HI93703-52 generic powder reagent reference image
Hanna’s generic powder-reagent reference photo supplied for HI93703-52. It does not show a glycine-specific label or establish physical packet inventory. Printed expiry is illustrative only.

Match the refill to the complete method

Use HI93703-52-0 glycine only for the additional reading in the documented ozone procedure. HI83326 is the primary reference here; HI83300 and HI83399 also document the conditional procedure. The ozone assay range belongs to the instrument method, not to glycine as a separate measurement.

A helper with a specific job

The glycine step belongs inside a two-reading ozone correction. Having a separate refill avoids confusing an optional interference-handling material with the ozone color reagent itself. HI93703-52 is the orderable pack; the instrument method identifies its powder as HI93703-52-0.

Decide from the sample, not from habit

If free or total chlorine is present or suspected, follow the additional procedure in your exact-model ozone manual. Chlorine-free samples use the standard ozone procedure without glycine. A routine glycine addition is not a substitute for identifying the relevant sample conditions or for performing the required standard reading.

Record A, prepare a fresh portion, then record B

When free or total chlorine is present or suspected, first perform the standard ozone measurement and record A. On a fresh 10 mL sample, zero again, add one HI93703-52-0 glycine packet and dissolve completely, then add one HI93757-0 ozone packet. Shake gently for 20 seconds and wait 2 minutes before reading B. Report ozone as A − B, not B alone.

Budget for ozone reagent as well

The completed correction consumes two HI93757-0 ozone portions and one glycine packet. This glycine pack is labeled 100 tests, but it contains neither the separate HI93757 ozone assay refill nor a photometer. The 100/300 nominal ozone pack labels must not be read as 100/300 corrected results, and nominal test labels alone do not establish an exact physical packet inventory.

Keep the reaction order and timing intact

For the additional reading on HI83326, dissolve glycine completely before adding the ozone reagent. After the ozone packet, shake gently for 20 seconds and wait 2 minutes or use the instrument timer. Report A − B. Do not report the additional reading alone as the corrected ozone result or improvise a different mixing sequence.

The correction does not replace matrix checks

Bromine, chlorine dioxide and iodine interfere. Above 500 mg/L hardness as CaCO3, the HI83326 manual calls for approximately 2 minutes of shaking after powder addition. Alkalinity above 250 mg/L as CaCO3 can prevent full color development or cause fading; follow the manual’s dilute-HCl neutralization guidance.

Prepare the complete setup

Provide a compatible photometer, suitable clean cuvettes with caps and stoppers, HI93757 ozone reagent and any other sample-treatment materials called for by the method. Check received lot/expiry markings and read the glycine US Safety Data Sheet. The linked ozone instrument manuals explain its legitimate procedural context; there is no separate glycine instrument assay being offered here.

Frequently Asked Questions

Is HI93703-52 a standalone ozone test?

No. It is an optional glycine helper pack. The ozone determination still requires separate HI93757-0 ozone reagent and a compatible photometer, plus the complete standard and additional measurement procedure.

When should I use it?

Only when free or total chlorine is present or suspected in the ozone sample, as directed by the instrument’s ozone method. It is not routinely required for chlorine-free water.

What do HI93703-52 and HI93703-52-0 mean?

HI93703-52 is the orderable 100-test glycine pack. HI93703-52-0 is the glycine powder component code printed in the ozone method and in its US Safety Data Sheet.

How do I obtain the corrected ozone result?

When free or total chlorine is present or suspected, first perform the standard ozone measurement and record A. On a fresh 10 mL sample, zero again, add one HI93703-52-0 glycine packet and dissolve completely, then add one HI93757-0 ozone packet. Shake gently for 20 seconds and wait 2 minutes before reading B. Report ozone as A − B, not B alone.

How much reagent does one corrected result consume?

Two ozone-reagent portions and one glycine packet: ozone reagent for A and ozone reagent plus glycine for B. The ozone reagent is sold separately. Do not treat the ozone pack’s nominal test count as the corrected-result count.

Can I change the order or shorten the wait?

Follow the manual: dissolve glycine completely on the fresh zeroed portion, add ozone reagent, shake gently for 20 seconds and wait 2 minutes or use the timer. Do not replace that sequence with an assumed chemical masking mechanism.

Which instrument manuals support this use?

The HI83326, HI83300 and HI83399 Ozone sections identify optional HI93703-52-0 glycine and the A − B correction. They are instrument method references, not standalone glycine manuals.

Does glycine resolve every ozone interference?

Bromine, chlorine dioxide and iodine interfere. Above 500 mg/L hardness as CaCO3, the HI83326 manual calls for approximately 2 minutes of shaking after powder addition. Alkalinity above 250 mg/L as CaCO3 can prevent full color development or cause fading; follow the manual’s dilute-HCl neutralization guidance. Follow all matrix precautions; this helper is for the specified chlorine-containing procedure, not a universal sample treatment.

    Product Specifications

    SpecificationDetail
    Orderable packHI93703-52
    Manufacturer capacity label100 tests — conditional glycine helper
    Actual component codeHI93703-52-0 glycine powder
    RoleAdditional ozone reading only when chlorine present or suspected
    Not a standalone assayHI93757 ozone reagent and compatible photometer separate
    Documented ozone methodsHI83326; HI83300; HI83399
    Primary ozone method contextHI83326: 0.00–2.00 mg/L as O3, colorimetric DPD
    Additional reading doseOne glycine packet dissolved, then one ozone packet; fresh 10 mL sample
    Full corrected-result consumptionTwo ozone portions plus one glycine packet; report A − B
    Normal additional-reading timingDissolve glycine; after ozone addition shake 20 seconds, wait 2 minutes
    Chlorine-free useNot routinely required; standard ozone procedure applies

    Ordering Information

    Catalog numberReagent pack
    HI93703-52100 tests — conditional glycine helper only; ozone reagent separate

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.