Apera TN500 Portable White-Light Turbidity Meter with Data Logging Portable Turbidity Meter Apera Instruments
Apera TN500 Portable White-Light Turbidity Meter with Data Logging Portable Turbidity Meter Apera Instruments
Apera TN500 Portable White-Light Turbidity Meter with Data Logging Portable Turbidity Meter Apera Instruments
Apera TN500 Portable White-Light Turbidity Meter with Data Logging Portable Turbidity Meter Apera Instruments

Apera TN500 Portable White-Light Turbidity Meter with Data Logging

$1,215.00

    Portable white-light results. A more complete record. TN500 AI483 for the defined measurement workflow.

    • White-light, 90° scattering; tungsten filament lamp, 400-600 nm
    • Normal, or selectable 5/10/15/20-reading TruRead with average, minimum, maximum and individual values
    • Windows PC-Link; mode-dependent onboard capacity
    • Includes five standards and six sample vials

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / TN500 / AI483

Portable white-light results.
A more complete record.

TN500 adds a documented results workflow to portable white-light turbidity testing. Select the TruRead sequence, review average/minimum/maximum and individual readings, and use Windows PC-Link when the result needs to leave the instrument.

Choose TN500 for white-light work that needs dated records and reporting, not because you expect a wider range or better published basic accuracy than TN420. This is a portable meter that also works on a laboratory surface, not a benchtop-only instrument.

Apera TN500 product photograph
Portable TN500 configuration. Operate on a level surface; do not hold during measurement.

0-1000 NTU

Instrument range

Method/reporting scope is a separate requirement.

400-600 nm

Tungsten white light

Match the required optical method.

Windows records

PC-Link + selectable TruRead

Capacity depends on mode.

Choose your turbidity workflowClick or tap to compare 4 meters + standardsChoose an item below - click or tap here to close

INSTRUMENT RANGE AND METHOD SCOPE ARE DIFFERENT

0-1000 NTU is the meter range.
It is not the undiluted EPA method range.

Apera describes TN500 as EPA 180.1 compliant. EPA 180.1 Rev. 2.0 covers 0-40 NTU and directs dilution for samples above 40 NTU. A broader instrument scale helps characterize a sample; it does not remove the method’s preparation, checks or reporting requirements.

Instrument positioning

Manufacturer-stated method compliance is not a model-specific EPA approval certificate.

Procedure and quality control

Follow the applicable method and program, including required verification, dilution and recordkeeping. A general weekly-check suggestion does not replace required method-specific checks.

WHY CHOOSE THIS CONFIGURATION

Match the work, not just the feature count.

Make the sequence visible

TruRead keeps the individual readings alongside average, minimum and maximum. Use the spread to assess changing or settling samples, not as permission to skip preparation.

Carry the result forward

Manual or automatic logging and Windows PC-Link support dated records and Excel-document export. No Mac, mobile, cloud or electronic-signature system is established here.

Plan the memory honestly

The 200-set headline applies to Normal mode. Longer TruRead sequences consume more storage, so export and memory planning belong in the workflow.

TN500 manufacturer illustration of USB Windows PC-Link workflow
Manufacturer workflow illustration. Windows computer is not included. Capacity details below qualify the general storage headline.

A result you can review
and carry into a report.

Choose 5, 10, 15 or 20 consecutive readings. TruRead displays the individual values with average, minimum and maximum; each reading is taken at 20-second intervals. Record manually or automatically according to the selected settings.

Windows PC-Link supports USB transfer and Excel-document export. The software also displays serial number, last-calibration information and parameters. These functions are not a verified complete historical audit trail or a claim of GLP/21 CFR Part 11 certification.

200 sets is not the capacity
of every recording mode.

Plan storage around the selected sequence, not the largest headline number. The exact manuals give these onboard capacities:

Measurement mode Stored sets
Normal 200
TruRead: 5 readings 100
TruRead: 10 readings 61
TruRead: 15 readings 44
TruRead: 20 readings 34

Mixed use changes the available capacity. Export needed records before clearing the instrument; its clear-all function removes stored records rather than offering a selective archival system.

PC-Link supports a separate live-PC workflow. When that workflow is running, the manuals describe measurements going to the computer rather than being stored in the instrument. This is not cloud backup or a verified electronic-signature/audit-trail system.

READ THE TWO NUMBERS DIFFERENTLY

Display resolution is not accuracy.

0.01 NTU

Low-range display increment

Other ranges use 0.1 and 1 NTU increments.

2% + stray light

Published reading-error specification

Accuracy: ≤±2% of reading plus stray light; stray light ≤0.02 NTU.

Worked specification example: at 1.00 NTU, the 2%-of-reading term alone is 0.02 NTU before the stray-light term. That arithmetic is not a complete method-uncertainty calculation or a promise of ±0.01 NTU measurement accuracy. Vials, sample preparation, calibration and the matrix remain part of the result.

Apera TN500 exact kit case and supplied components
Exact manufacturer TN500 photograph, cropped to its numbered photo area. Matching item key is provided as readable text.

Know what arrives
in the carrying case.

TN500 meter; five standards at 0/20/100/400/800 NTU; six numbered sample vials; 10 mL silicone oil; microfiber cloth; 5 V/1 A adapter; USB cable; PC-Link software flash drive; manual and case.

  1. TN500 meter
  2. 0 NTU standard
  3. 20 NTU standard
  4. 100 NTU standard
  5. 400 NTU standard
  6. 800 NTU standard
  7. Six sample vials
  8. Silicone oil
  9. Software flash drive
  10. Power adapter
  11. Microfiber cloth
  12. Manual

USB cable is also included; the photo does not number it separately.

The complete meter kit includes zero. Replacement nonzero standards are a separate purchase; do not read a replacement-set name as all five calibration solutions.

SAMPLE PREPARATION IS PART OF THE MEASUREMENT

The vial and the timing
can change the answer.

Prepare the sample vial

Use the specified 25 × 60 mm numbered sample vial and approximately 18 mL of sample. Keep the matching cap paired with it and follow the exact rinsing/mixing procedure.

Control bubbles and settling

Fine bubbles can raise readings; settling and light-absorbing material can change them. Keep preparation and waiting times consistent rather than averaging away a method problem.

Protect the optical surfaces

Keep the vial clean and dry, avoid fingerprints/scratches, align its mark and close the cover. Use oil only as instructed and remove excess.

Work on a flat, level surface, not with the meter in your hand. Never pour sample into or wash the optical holder. The IP67 rating is not a direct-immersion measurement method. Turbidity is not a direct TSS mass measurement or a complete water-safety test.

Check zero and the right standards.
Keep nonzero vials sealed.

The kit is supplied with five calibration values and is factory calibrated across its range. The manual permits later calibration with two or more appropriate points bracketing the expected range; local method/QC requirements still govern. Select the correct value because the instrument does not identify a standard automatically.

For low-range work, follow the manual’s zero check, warm-up and numbered-vial guidance. A display increment is not proof that an unchecked zero or contaminated vial is adequate.

The four nonzero AMCO standard vials must stay sealed. Zero-vial opening/refill instructions are different. Do not vigorously shake standards or infer that a generic shelf-life claim permits opening them.

Match replacement standards
to this white-light model.

Compatible accessory: T500-1 sealed AMCO nonzero standards is explicitly listed for TN500 and the other white-light model. Its four values are 20/100/400/800 NTU; it does not supply a meter or zero standard.

The infrared TN480 specifies T200-1 instead. Shared concentration labels do not establish universal cross-model or cross-brand compatibility.

Watch Apera’s turbidity overview.

The official family tutorial introduces the workflow. Use the exact TN500 manual for its controls, optical method, standards and software. The video is not a model-specific certification or a replacement for sealed-vial instructions.

TN500 buying and workflow questions

Is TN500 portable or a benchtop-only meter?

TN500 AI483 is portable, with a rechargeable lithium battery and carrying case. Use it on a flat, level surface during measurement. Laboratory use does not turn it into a benchtop-only model.

Why choose TN500 instead of TN420?

Choose TN500 for selectable TruRead sequences, dated record storage, calibration information and Windows reporting. Both publish a 0-1000 NTU range and the same basic accuracy, so logging is the key upgrade rather than a better stated accuracy figure.

Can it store 200 TruRead reports?

Not at every setting. Capacity is 200 Normal sets, or 100/61/44/34 TruRead sets for 5/10/15/20-reading sequences respectively. Mixed use changes capacity. Export needed records before clearing the instrument’s memory.

Does PC-Link work with Mac or a phone?

The documented PC-Link workflow is Windows-based, with software supplied on a flash drive and USB connection. No Mac/mobile/cloud support or specific modern Windows-version guarantee is established. Confirm institutional driver/software requirements before deployment.

Does GLP data management mean a certified audit trail?

No. The documented features include identifiers, date/time, modes, values and last-calibration information. They do not establish electronic signatures, a tamper-evident historical audit trail or 21 CFR Part 11 compliance.

Does EPA 180.1 compliant mean the meter is EPA approved?

No. It is Apera’s stated instrument-method positioning. EPA 180.1’s range and dilution requirements, required controls and your reporting program still apply. The 0-1000 NTU display range is not the undiluted method range.

Which replacement standards fit TN500?

T500-1 AI4205 is the four-value nonzero AMCO set for TN500 and TN420. It does not contain zero or a meter. The complete TN500 meter kit includes five standards, including zero. TN480 uses T200-1 instead.

Can TruRead fix bubbles or settling automatically?

It can show a sequence and its spread; it does not remove the underlying sample-preparation problem. Control bubbles, vial condition and timing. Do not treat averaging as a guarantee that a changing sample is correctly represented.

Confirm the method.
Choose the exact configuration.

Review TN500 AI483 and return to the live price and ordering controls. Ask Blue Tiger Scientific to clarify the exact configuration, method or documentation requirements before ordering.

Back to price and ordering ↑
    SpecificationDetail
    BrandApera Instruments
    Model / manufacturer catalogTN500 / AI483
    Optical principleWhite-light, 90° scattering; tungsten filament lamp, 400-600 nm
    Method positioningManufacturer-stated EPA 180.1 compliance; not an independent approval guarantee
    Instrument range0-1000 NTU; applicable method range is separate
    Display resolution0.01 / 0.1 / 1 NTU across ranges; not accuracy
    Accuracy≤±2% of reading plus stray light
    Stray light≤0.02 NTU
    Repeatability≤±1% of reading or 0.02 NTU, whichever is greater
    Normal measurement20 seconds per Normal reading; TruRead takes one reading every 20 seconds
    Measurement modesNormal, or selectable 5/10/15/20-reading TruRead with average, minimum, maximum and individual values
    Records200 Normal sets; TruRead capacities depend on selected sequence length
    Power3.7 V rechargeable lithium battery; USB charging
    Calibration values0 / 20 / 100 / 400 / 800 NTU
    Replacement nonzero setT500-1 / AI4205 for the four nonzero white-light standards; zero refill is separate
    Meter-kit zero standardIncluded; not the same contents as a four-value replacement set
    Sample vial25 mm diameter × 60 mm, high-borosilicate glass with cap
    Sample-test volumeApproximately 18 mL; not a standard-kit fill volume
    DisplayTFT color screen
    Ingress ratingIP67; do not pour into or wash the optical holder
    Operating temperature0-50 °C
    Published meter dimensions90 × 203 × 80 mm
    Published meter mass385 g
    Calibration-solution storage5-30 °C; never freeze; follow expiry label
    Onboard capacity by modeNormal 200; TruRead 5/10/15/20 readings: 100/61/44/34 sets
    PC software / exportWindows PC-Link; USB transfer and Excel-document export; no Mac/mobile/cloud guarantee
    Data features, not certificationDate/time, identifiers and calibration information; no verified electronic-signature or complete historical audit-trail claim

    Ordering Information

    Ordering detailIncluded configuration
    Manufacturer catalogAI483
    Preserved Blue Tiger SKUBTS-AI483
    Order contentsTN500 meter; five standards at 0/20/100/400/800 NTU; six numbered sample vials; 10 mL silicone oil; microfiber cloth; 5 V/1 A adapter; USB cable; PC-Link software flash drive; manual and case.
    Order unit1 instrument kit

    Warranty Information

    APERA INSTRUMENTS, LLC warrants this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of TWO YEARS for the instrument from the delivery.

    This limited warranty does NOT cover any issues due to:

    • Accidental damage
    • Improper use
    • Normal wear and tear
    • Transportation
    • Storage
    • Failure to follow the product instructions
    • Unauthorized maintenance, modifications, combination or use with any products, materials, processes, systems or other matter
    • Unauthorized repair
    • External causes such as accidents, abuse, or other actions or events beyond our reasonable control.

    TN500 official documents

    The exact-model manual controls operation and configuration. The family brochure is a supplemental selection reference; it also illustrates other models and accessories. A four-value replacement set is not the complete five-standard meter-kit package. Each card opens a PDF in a new tab.