Apera PH60-SA Alkaline/Salty-Water pH Kit with LabSen 845 pH Meter Apera Instruments
Apera PH60-SA Alkaline/Salty-Water pH Kit with LabSen 845 pH Meter Apera Instruments
Apera PH60-SA Alkaline/Salty-Water pH Kit with LabSen 845 pH Meter Apera Instruments
Apera PH60-SA Alkaline/Salty-Water pH Kit with LabSen 845 pH Meter Apera Instruments
Apera PH60-SA Alkaline/Salty-Water pH Kit with LabSen 845 pH Meter Apera Instruments
Apera PH60-SA Alkaline/Salty-Water pH Kit with LabSen 845 pH Meter Apera Instruments
Apera PH60-SA Alkaline/Salty-Water pH Kit with LabSen 845 pH Meter Apera Instruments
Apera PH60-SA Alkaline/Salty-Water pH Kit with LabSen 845 pH Meter Apera Instruments
Apera PH60-SA Alkaline/Salty-Water pH Kit with LabSen 845 pH Meter Apera Instruments
Apera PH60-SA Alkaline/Salty-Water pH Kit with LabSen 845 pH Meter Apera Instruments

Apera PH60-SA Alkaline/Salty-Water pH Kit with LabSen 845

$249.00

    Salty or alkaline water? Start with the electrode. The PH60-SA pairs PH60 with LabSen 845 for its defined sample workflow.

    • Exact external probe: LabSen 845 / AI3237
    • Includes pH 4.00, 7.00 and 12.45 buffers, CalPod and KCl storage solution
    • Meter limits and electrode/sample limits are separate

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / PH60-SA / AI3727

Salty or alkaline water?
Start with the electrode.

PH60-SA is a pH kit selected around LabSen 845 for suitable strong-alkaline and high-salinity aqueous samples. Its specialized glass/reference combination addresses a different sample question from a general-purpose water probe.

Choose AI3727 when the chemistry calls for the 845 configuration. This measures pH and temperature, not salt concentration, and does not certify compatibility with every caustic or salt mixture.

Apera PH60-SA with specified LabSen 845 external electrode
Matched kit: PH60 body and LabSen 845. The external electrode is not an extra generic PH60-E.

LabSen 845

Supplied electrode

Replacement AI3237

0.01 pH

Meter resolution

Meter accuracy: ±0.01 pH ±1 digit

8-pin

Matched external connection

Not an ordinary BNC-only substitution

Find the PH60 kit for your sampleClick or tap to compare all 8 kitsChoose a model below - click or tap here to close

TWO DIFFERENT QUESTIONS

pH in salty water is not
a salinity measurement.

pH

The parameter this kit measures

LabSen 845

The electrode selected for the sample matrix

12.45

Included US alkaline calibration buffer

The US kit supplies 4.00, 7.00 and 12.45 buffers. A regional brochure’s different buffer set does not define the US package. Confirm high-salt/alkaline chemistry and the working method rather than reading a maximum salt concentration into the application name.

Exact PH60-SA kit diagram from its currentUS manufacturer manual
Manufacturer kit diagram. The text checklist provides readable ordering details; solution volumes are not assumed from other regions.

Know the exact probe
and standards in the case.

PH60 meter body, LabSen 845 external pH/temperature electrode, CalPod solution organizer, pH 4.00, 7.00 and 12.45 buffers, 3M KCl storage solution, protective cap, instructions and carrying case. Four AAA batteries are factory-installed per the model’s preparation instructions.

The current US kit buffer set is pH 4.00, 7.00 and 12.45. Match that working set to your sample and calibration method; do not assume every specialized PH60 package contains the same buffers.

SAMPLE FIT BEFORE FEATURE COUNT

Where this configuration fits.

Strong-alkaline samples

Match the exact chemistry and pH method to the probe. The supplied US buffer set includes 12.45 for this configuration.

High-salinity water

Use pH sensing appropriate to the ionic matrix. The meter does not produce a salinity result simply because the sample contains salt.

General aqueous comparison

Keep calibration, temperature and sample handling consistent when comparing a difficult matrix with ordinary water.

The electrode is the specialized part.

Specialized alkaline-sample glass and polymer reference; non-refillable. The open junction and its sample contact are part of the method, not a universal chemical-compatibility or maintenance-free guarantee.

Manufacturer high-salt positioning is not a verified maximum salinity or a chemical-compatibility list. A pH glass selection is not a conductivity or salinity measurement mode.

Manufacturer PH60-SA sample/probe reference illustration
Reference imagery illustrates the application or technology. The supplied exact probe is LabSen 845.

Set up the method before chasing the number.

Use the current US set 4.00/7.00/12.45 and the manufacturer’s calibration procedure appropriate to the expected sample. Confirm matrix and exposure conditions for the 845 rather than selecting from the meter’s broad display range.

Calibrate the pH system

Use the specified kit buffers and current instructions. Start at neutral as directed, then choose the appropriate additional points. Do not infer an included ORP or EC probe.

Make the right contact

Keep glass and junction in contact with a representative sample, limit carryover, and wait for a stable reading under the defined method.

Meter electronics and sample suitability are different.

The current US specialized-kit manual specifies a PH60 display range of -2.00 to 16.00 pH, 0.01 pH resolution and ±0.01 pH ±1 digit meter accuracy. Those numbers do not by themselves establish probe-range, chemical compatibility or total method accuracy.

Temperature measurement/ATC is 0-100 °C in these current US kit instructions. A higher electrode-only temperature figure does not extend that electronic interval or validate every part of the assembly in the sample.

This probe’s temperature context

Meter/ATC 0-100 °C in current US kit manual; electrode-only higher figures do not extend the complete kit

Storage solution is not a refill instruction.

The listed LabSen 845 is non-refillable. Its internal reference/electrolyte description is separate from the external 3M KCl storage vial. Do not open/refill the reference because a chemical name appears in a table.

Rinse before and after measurements without rubbing the glass. Use contaminant-specific manufacturer care rather than an improvised chemical recipe; after deep cleaning follow the required rehydration and recalibration sequence.

Store the probe in its tightly closed vial with the specified 3M KCl solution, not tap, RO, distilled or deionized water. Keep solution fresh and the connector clean/dry. A dry or poorly stored probe needs the model’s recovery routine before calibration.

See the LabSen family technology.

Apera’s electrode-family introduction explains the general technology. It is not an exact PH60-SA operating tutorial; use this kit’s current manual for sample preparation, limits and care.

Related general-water measurement workflows.

These are separate instruments for different water-measurement tasks, not substitute specialized electrodes for PH60-SA. A general-water meter link does not establish HF, caustic, hot-process or direct-food compatibility.

Related workflow: Hanna HI98195 general-water pH/ORP/EC meter

Related workflow: Hanna HI98197 pure-water EC/resistivity meter

PH60-SA buying and method questions

Does PH60-SA measure salinity?

No. It measures pH and temperature with LabSen 845. High-salinity suitability describes the sample context, not an included salinity readout.

What buffers come in the US AI3727 kit?

The current US manual/page list pH 4.00, 7.00 and 12.45. Do not substitute the 10.01 set from a regional brochure as the supplied US kit contents.

What other items are included?

PH60, LabSen 845, CalPod, 3M KCl storage solution, cap, instructions and case are listed, with installed four AAA batteries indicated by the preparation instructions.

Can it test any strongly alkaline or salty formulation?

No maximum salinity or universal species/caustic compatibility is verified. Confirm the actual matrix and conditions against current 845 guidance before selection.

Is the electrode refillable?

No. The 845 is non-refillable. Polymer/internal electrolyte terminology is separate from the 3M KCl solution used in the storage vial.

Why not use the meter’s entire -2 to 16 pH range as the probe range?

That is an electronic display range, not an unrestricted sample-range claim for the 845. Select the electrode and method against their own limits.

Can a 130 °C probe rating extend PH60 temperature compensation?

No. Current US meter/ATC specification is 0-100 °C, and electrode source ratings differ. A higher probe-only figure does not validate the entire assembly at that temperature.

Which replacement and storage routine apply?

Use LabSen 845, AI3237, with its 8-pin connection. Store in the specified 3M KCl vial and follow the current cleaning/rehydration/calibration directions, not pure-water storage.

Match the sample.
Confirm the exact kit.

Review PH60-SA and its LabSen 845 configuration, then return to the price and ordering controls. Blue Tiger Scientific can help clarify exact kit, probe and method requirements before ordering.

Back to price and ordering ↑
    SpecificationDetail
    BrandApera Instruments
    Kit / manufacturer catalogPH60-SA / AI3727
    Included electrodeLabSen 845 / AI3237
    Electrode interface8-pin; matched PH60 socket arrangement
    RefillableNo; storage liquid is external
    JunctionOpen
    Specialized reference/sensorSpecialized alkaline-sample glass and polymer reference; non-refillable
    Meter pH range-2.00 to 16.00 pH
    Meter pH resolution0.01 pH
    Meter pH accuracy±0.01 pH ±1 digit
    Temperature measurement / ATC0-100 °C in current US kit manual; not an unrestricted probe/system rating
    Temperature resolution0.1 °C
    Probe temperature contextMeter/ATC 0-100 °C in current US kit manual; electrode-only higher figures do not extend the complete kit
    Supplied US pH bufferspH 4.00, 7.00 and 12.45
    External storage solution3M KCl; not a refill instruction
    Power4 AAA alkaline batteries; installed per preparation guide
    ReadoutpH and temperature
    Optional ORPORP electrode not supplied or implied by this kit
    Sample-method noteManufacturer high-salt positioning is not a verified maximum salinity or a chemical-compatibility list. A pH glass selection is not a conductivity or salinity measurement mode.

    Ordering Information

    Ordering detailIncluded configuration
    Manufacturer catalogAI3727
    Blue Tiger SKUBTS-AI3727
    Working kitPH60 meter body, LabSen 845 external pH/temperature electrode, CalPod solution organizer, pH 4.00, 7.00 and 12.45 buffers, 3M KCl storage solution, protective cap, instructions and carrying case. Four AAA batteries are factory-installed per the model’s preparation instructions.
    Order unit1 kit

    Warranty Information

    APERA INSTRUMENTS, LLC warrants  this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of TWO YEARS for the instrument and SIX MONTHS for the probe from the delivery.

    This limited warranty does NOT cover any issues due to:

    • Accidental damage
    • Improper use
    • Normal wear and tear
    • Transportation
    • Storage
    • Failure to follow the product instructions
    • Unauthorized maintenance, modifications, combination or use with any products, materials, processes, systems or other matter
    • Unauthorized repair
    • External causes such as accidents, abuse, or other actions or events beyond our reasonable control.

    PH60-SA official documents

    Use the current US exact-kit manual for the supplied configuration and operation. The LabSen handbook is additional method/selection reference, not a replacement for those instructions. Each card opens a PDF in a new tab.