Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera PH60-HT Hot/Caustic-Water pH Kit with LabSen 865 pH Meter Apera Instruments
Apera PH60-HT Hot/Caustic-Water pH Kit with LabSen 865 pH Meter Apera Instruments
Apera PH60-HT Hot/Caustic-Water pH Kit with LabSen 865 pH Meter Apera Instruments
Apera PH60-HT Hot/Caustic-Water pH Kit with LabSen 865 pH Meter Apera Instruments
Apera PH60-HT Hot/Caustic-Water pH Kit with LabSen 865 pH Meter Apera Instruments
Apera PH60-HT Hot/Caustic-Water pH Kit with LabSen 865 pH Meter Apera Instruments
Apera PH60-HT Hot/Caustic-Water pH Kit with LabSen 865 pH Meter Apera Instruments
Apera PH60-HT Hot/Caustic-Water pH Kit with LabSen 865 pH Meter Apera Instruments
Apera PH60-HT Hot/Caustic-Water pH Kit with LabSen 865 pH Meter Apera Instruments
Apera PH60-HT Hot/Caustic-Water pH Kit with LabSen 865 pH Meter Apera Instruments

Apera PH60-HT Hot/Caustic-Water pH Kit with LabSen 865

$275.00

    Heat tolerance and compensation are not the same specification. The PH60-HT pairs PH60 with LabSen 865 for its defined sample workflow.

    • Exact external probe: LabSen 865 / AI3241
    • Includes pH 4.00, 7.00 and 10.01 buffers, CalPod and KCl storage solution
    • Meter limits and electrode/sample limits are separate

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / PH60-HT / AI3731

Heat tolerance and compensation
are not the same specification.

PH60-HT pairs the portable body with the specialized LabSen 865 pH/temperature electrode for suitable hot and/or caustic aqueous sample work. Its value is the matched probe choice, not a single temperature number copied onto the whole kit.

Choose AI3731 after matching the electrode, PH60 electronics and sample conditions. A probe-only 130/140 °C source rating is not a handheld-kit temperature or pressure certification.

Apera PH60-HT with specified LabSen 865 external electrode
Matched kit: PH60 body and LabSen 865. The external electrode is not an extra generic PH60-E.

LabSen 865

Supplied electrode

Replacement AI3241

0.01 pH

Meter resolution

Meter accuracy: ±0.01 pH ±1 digit

8-pin

Matched external connection

Not an ordinary BNC-only substitution

Find the PH60 kit for your sampleClick or tap to compare all 8 kitsChoose a model below - click or tap here to close

KEEP THREE LIMITS SEPARATE

A high-temperature probe rating
does not extend the meter’s ATC.

0-100 °C

PH60 temperature/ATC interval in the current US kit manual

Probe rating

A separate 865 field; source revisions list different upper bounds

Whole system

Check connector, body and actual process conditions

The kit manual’s 140 °C electrode figure and a current standalone 130 °C figure are not interchangeable with meter compensation. Neither establishes continuous service, pressure capability or a complete handheld-kit 140 °C claim.

Choose a properly evaluated process system when continuous hot measurement is required. Specialized sample testing is a different task.

Exact PH60-HT kit diagram from its currentUS manufacturer manual
Manufacturer kit diagram. The text checklist provides readable ordering details; solution volumes are not assumed from other regions.

Know the exact probe
and standards in the case.

PH60 meter body, LabSen 865 external pH/temperature electrode, CalPod solution organizer, pH 4.00, 7.00 and 10.01 buffers, 3M KCl storage solution, protective cap, instructions and carrying case. Four AAA batteries are factory-installed per the model’s preparation instructions.

The current US kit buffer set is pH 4.00, 7.00 and 10.01. Match that working set to your sample and calibration method; do not assume every specialized PH60 package contains the same buffers.

SAMPLE FIT BEFORE FEATURE COUNT

Where this configuration fits.

Hot aqueous sample checks

Confirm the exact electrode revision and the complete assembly’s limits. High-temperature exposure affects electrode aging; no continuous-hot service-life promise is made.

Caustic-water processes

Match chemistry, temperature and contact conditions to current 865 guidance. Do not assume suitability for every solvent, HF-containing liquid or pressurized process.

A defined laboratory method

Keep calibration and sample temperature handling within the method. Electronic compensation does not eliminate every temperature effect.

The electrode is the specialized part.

Specialized high-temperature/caustic-water electrode; non-refillable. The ptfe junction and its sample contact are part of the method, not a universal chemical-compatibility or maintenance-free guarantee.

Current US sources disagree on the 865 electrode upper rating. Do not select the highest number and treat it as permission for continuous process immersion, pressurized installation or temperature compensation beyond 100 °C.

Manufacturer PH60-HT sample/probe reference illustration
Reference imagery illustrates the application or technology. The supplied exact probe is LabSen 865.

Set up the method before chasing the number.

Evaluate three boundaries before ordering: the PH60 measurement/ATC specification, the exact 865 electrode rating, and the real assembly/process conditions. Keep meter body and connectors out of inappropriate hot or wet exposure.

Calibrate the pH system

Use the specified kit buffers and current instructions. Start at neutral as directed, then choose the appropriate additional points. Do not infer an included ORP or EC probe.

Make the right contact

Keep glass and junction in contact with a representative sample, limit carryover, and wait for a stable reading under the defined method.

Meter electronics and sample suitability are different.

The current US specialized-kit manual specifies a PH60 display range of -2.00 to 16.00 pH, 0.01 pH resolution and ±0.01 pH ±1 digit meter accuracy. Those numbers do not by themselves establish probe-range, chemical compatibility or total method accuracy.

Temperature measurement/ATC is 0-100 °C in these current US kit instructions. A higher electrode-only temperature figure does not extend that electronic interval or validate every part of the assembly in the sample.

This probe’s temperature context

Current US meter/ATC 0-100 °C; probe sources list differing 130/140 °C upper ratings separately

Storage solution is not a refill instruction.

The listed LabSen 865 is non-refillable. Its internal reference/electrolyte description is separate from the external 3M KCl storage vial. Do not open/refill the reference because a chemical name appears in a table.

Rinse before and after measurements without rubbing the glass. Use contaminant-specific manufacturer care rather than an improvised chemical recipe; after deep cleaning follow the required rehydration and recalibration sequence.

Store the probe in its tightly closed vial with the specified 3M KCl solution, not tap, RO, distilled or deionized water. Keep solution fresh and the connector clean/dry. A dry or poorly stored probe needs the model’s recovery routine before calibration.

See the LabSen family technology.

Apera’s electrode-family introduction explains the general technology. It is not an exact PH60-HT operating tutorial; use this kit’s current manual for sample preparation, limits and care.

Related general-water measurement workflows.

These are separate instruments for different water-measurement tasks, not substitute specialized electrodes for PH60-HT. A general-water meter link does not establish HF, caustic, hot-process or direct-food compatibility.

Related workflow: Hanna HI98195 general-water pH/ORP/EC meter

Related workflow: Hanna HI98197 pure-water EC/resistivity meter

PH60-HT buying and method questions

Is PH60-HT a 140 °C complete kit?

No. 140 °C appears as an electrode-only rating in some sources; other 865 sources list 130 °C. The current US PH60 meter temperature/ATC specification is 0-100 °C. These are separate boundaries.

What is included in AI3731?

The kit includes PH60, LabSen 865, CalPod, pH 4.00/7.00/10.01 buffers, 3M KCl storage solution, cap, instructions and case, with installed four AAA batteries supported by model preparation.

Can it be left permanently in a hot process?

No continuous process-service or pressure rating is established by these sources. The manual advises minimizing high-temperature exposure; evaluate a proper process-rated system when continuous measurement is required.

Does automatic temperature compensation remove all temperature effects?

No. Compensation is an electronic function within its specified interval, not a blanket guarantee for the sample chemistry, the reference system or an overheated component.

Is LabSen 865 refillable?

No. It is listed as non-refillable despite differing internal KCl/gel wording across sources. Use 3M KCl externally for storage as instructed rather than opening the reference.

Is this the HF-specific kit?

No. PH60-HF uses LabSen 835 with its own restricted conditions. High-temperature/caustic positioning of 865 does not establish HF compatibility.

Which replacement electrode is specified?

LabSen 865, AI3241, with the matching 8-pin interface. Confirm exact revision and intended conditions before relying on a high-end rating.

How should it be maintained?

Use the current kit/probe care instructions, rinsing without abrasion and storing in specified 3M KCl. Rehydrate and recalibrate after appropriate cleaning. No guaranteed life under prolonged heat is promised.

Match the sample.
Confirm the exact kit.

Review PH60-HT and its LabSen 865 configuration, then return to the price and ordering controls. Blue Tiger Scientific can help clarify exact kit, probe and method requirements before ordering.

Back to price and ordering ↑
    SpecificationDetail
    BrandApera Instruments
    Kit / manufacturer catalogPH60-HT / AI3731
    Included electrodeLabSen 865 / AI3241
    Electrode interface8-pin; matched PH60 socket arrangement
    RefillableNo; storage liquid is external
    JunctionPTFE
    Specialized reference/sensorSpecialized high-temperature/caustic-water electrode; non-refillable
    Meter pH range-2.00 to 16.00 pH
    Meter pH resolution0.01 pH
    Meter pH accuracy±0.01 pH ±1 digit
    Temperature measurement / ATC0-100 °C in current US kit manual; not an unrestricted probe/system rating
    Temperature resolution0.1 °C
    Probe temperature contextCurrent US meter/ATC 0-100 °C; probe sources list differing 130/140 °C upper ratings separately
    Supplied US pH bufferspH 4.00, 7.00 and 10.01
    External storage solution3M KCl; not a refill instruction
    Power4 AAA alkaline batteries; installed per preparation guide
    ReadoutpH and temperature
    Optional ORPORP electrode not supplied or implied by this kit
    Sample-method noteCurrent US sources disagree on the 865 electrode upper rating. Do not select the highest number and treat it as permission for continuous process immersion, pressurized installation or temperature compensation beyond 100 °C.

    Ordering Information

    Ordering detailIncluded configuration
    Manufacturer catalogAI3731
    Blue Tiger SKUBTS-AI3731
    Working kitPH60 meter body, LabSen 865 external pH/temperature electrode, CalPod solution organizer, pH 4.00, 7.00 and 10.01 buffers, 3M KCl storage solution, protective cap, instructions and carrying case. Four AAA batteries are factory-installed per the model’s preparation instructions.
    Order unit1 kit

    Warranty Information

    APERA INSTRUMENTS, LLC warrants  this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of TWO YEARS for the instrument and SIX MONTHS for the probe from the delivery.

    This limited warranty does NOT cover any issues due to:

    • Accidental damage
    • Improper use
    • Normal wear and tear
    • Transportation
    • Storage
    • Failure to follow the product instructions
    • Unauthorized maintenance, modifications, combination or use with any products, materials, processes, systems or other matter
    • Unauthorized repair
    • External causes such as accidents, abuse, or other actions or events beyond our reasonable control.

    PH60-HT official documents

    Use the current US exact-kit manual for the supplied configuration and operation. The LabSen handbook is additional method/selection reference, not a replacement for those instructions. Each card opens a PDF in a new tab.