    Read the blue column against a white background and record the serial number with the result. A transparent FEP coating is designed to retain glass fragments and fill if breakage occurs.

    • Match the immersion type to the procedure: total or marked partial immersion.
    • Choose one Celsius or Fahrenheit range; graduations and overall length are listed by model.
    • Sold individually. Photographs show a representative coated instrument, not every scale.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Order Now
FIND YOUR FIT

Compare FEP-encapsulated thermometers · representative family photo

Prices apply to the selling unit shown for each configuration. Check the ordering information for package contents.

Available configurations for Serialized Encapsulated Glass Thermometers
Product Catalog No. Configuration Selling unit Price Order
80701E BTS-80701E −30 to 120°F · 2°F divisions · total immersion · 12 in. 1 each $59.00 per listed selling unit

80901E BTS-80901E −30 to 120°F · 2°F divisions · partial immersion · 12 in. 1 each $59.00 per listed selling unit

80702E BTS-80702E −4 to 230°F · 2°F divisions · total immersion · 12 in. 1 each $59.00 per listed selling unit

80902E BTS-80902E −4 to 230°F · 2°F divisions · partial immersion · 12 in. 1 each $59.00 per listed selling unit

80703E BTS-80703E 0 to 300°F · 2°F divisions · total immersion · 12 in. 1 each $59.00 per listed selling unit

80903E BTS-80903E 0 to 300°F · 2°F divisions · partial immersion · 12 in. 1 each $59.00 per listed selling unit

80704E BTS-80704E 30 to 220°F · 2°F divisions · total immersion · 15.38 in. 1 each $75.00 per listed selling unit

80904E BTS-80904E 30 to 220°F · 2°F divisions · partial immersion · 15.38 in. 1 each $75.00 per listed selling unit

80706E BTS-80706E −35 to 50°C · 1°C divisions · total immersion · 12 in. 1 each $59.00 per listed selling unit

80906E BTS-80906E −35 to 50°C · 1°C divisions · partial immersion · 12 in. 1 each $59.00 per listed selling unit

80707E BTS-80707E −20 to 110°C · 1°C divisions · total immersion · 12 in. 1 each $59.00 per listed selling unit

80907E BTS-80907E −20 to 110°C · 1°C divisions · partial immersion · 12 in. 1 each $59.00 per listed selling unit

80708E BTS-80708E −20 to 150°C · 1°C divisions · total immersion · 12 in. 1 each $59.00 per listed selling unit

80908E BTS-80908E −20 to 150°C · 1°C divisions · partial immersion · 12 in. 1 each $59.00 per listed selling unit

Choose an encapsulated thermometer for your bath

When a glass thermometer is used over a sample, the coating and the immersion mark answer different questions. The FEP sleeve is designed to retain broken glass and fill if the instrument breaks. The immersion type tells you how much of the stem belongs in the medium for a reading.

Representative VEE GEE FEP-encapsulated thermometer shown full length
Representative photograph of the unarmored, FEP-encapsulated family. Use the model row—not the photographed markings—to choose the scale and immersion type.

Match the immersion mark and the vessel

Same range, different working depth

For a −20 to 110°C bath, 80707E and 80907E both have 1°C marks. Use the total-immersion 80707E when the procedure immerses the bulb and liquid column up to the reading. Choose 80907E when the bath surface must meet the partial-immersion line.

Allow room for the longer Fahrenheit pair

The 30 to 220°F models are 15.38 inches long, compared with 12 inches for the other ranges. Check clearance around the vessel and clamp before choosing 80704E or 80904E. Overall length is not a specified immersion depth.

Buyer FAQs

What does the FEP coating do if the thermometer breaks?

The coating is designed to retain the glass fragments and liquid fill. It does not make the instrument unbreakable. If damage is suspected, remove it from service and follow your facility’s procedure for handling the instrument and any affected sample.

Can I substitute a partial-immersion model with the same range?

Not on the basis of range alone. Total immersion and partial immersion place different lengths of the liquid column in the medium. Match the designation in the method; for a partial-immersion instrument, look for the line on the actual stem.

Which models cover readings below −20°C?

80706E (total) and 80906E (partial) reach −35°C, but stop at 50°C. The −20 to 110°C and −20 to 150°C pairs reach higher temperatures, but neither covers the colder interval.

Which Fahrenheit model fits a 30 to 220°F procedure?

Choose 80704E for total immersion or 80904E for partial immersion. Both have 2°F divisions and a 15.38-inch overall length. If clearance is limited, do not assume that a shorter model with an overlapping range meets the procedure.

Is each thermometer marked in both Celsius and Fahrenheit?

No. The catalog number specifies one scale: 1°C divisions on the Celsius models or 2°F divisions on the Fahrenheit models. Select the units your procedure records. The family photograph is not a scale reference for every model.

Does a serial number establish calibration?

The serial number identifies the individual instrument in your equipment log. It does not, by itself, supply calibration results or a certificate. Confirm any required certificate, test points or traceability before ordering.

What is included, and is there a metal guard?

Each selected catalog number supplies one FEP-encapsulated glass thermometer. These E-suffix models have no metal armor. If your procedure specifies a guard, do not substitute this family simply because the range and graduations match.

    SpecificationDetail
    BrandVEE GEE Scientific
    Ordering information1 each; select the catalog number for the required range, graduation and immersion type.
    ConstructionFEP-encapsulated glass; no metal armor.
    Reading the scaleBlue liquid fill against a white background; one temperature scale per instrument.
    IdentificationIndividually serialized for equipment records.
    Overall length12 in., except 80704E and 80904E (15.38 in.). Not an immersion-depth specification.

    Ordering Information

    Catalog no.Range & divisionImmersion & length
    80701E−30 to 120°F · 2°F stepsTotal · 12 in.
    80901E−30 to 120°F · 2°F stepsPartial · 12 in.
    80702E−4 to 230°F · 2°F stepsTotal · 12 in.
    80902E−4 to 230°F · 2°F stepsPartial · 12 in.
    80703E0 to 300°F · 2°F stepsTotal · 12 in.
    80903E0 to 300°F · 2°F stepsPartial · 12 in.
    80704E30 to 220°F · 2°F stepsTotal · 15.38 in.
    80904E30 to 220°F · 2°F stepsPartial · 15.38 in.
    80706E−35 to 50°C · 1°C stepsTotal · 12 in.
    80906E−35 to 50°C · 1°C stepsPartial · 12 in.
    80707E−20 to 110°C · 1°C stepsTotal · 12 in.
    80907E−20 to 110°C · 1°C stepsPartial · 12 in.
    80708E−20 to 150°C · 1°C stepsTotal · 12 in.
    80908E−20 to 150°C · 1°C stepsPartial · 12 in.

    Heathrow Scientific: Shipping & Return Policy

    At Blue Tiger Scientific, we're proud to offer a wide range of authentic Heathrow Scientific products. Please review the following policies, which apply to all Heathrow Scientific purchases made through our store. Remember, all return requests must be initiated directly with Blue Tiger Scientific.

    Shipping Policy

    Orders for Heathrow Scientific products are fulfilled and shipped straight from Heathrow Scientific's facilities, primarily utilizing reliable carriers like FedEx or UPS. FedEx Ground is the standard shipping method for all orders.


    Heathrow Scientific ships only to residential or business addresses within the United States. We cannot ship to P.O. Boxes.


    Orders placed outside of regular business hours, on weekends, or during holidays will be processed on the next business day, subject to product availability and carrier schedules.


    Delivery times can vary based on the specific product's availability, the overall size of your order, and current carrier logistics.


    Once your order has shipped, Blue Tiger Scientific and Heathrow Scientific are not responsible for unforeseen carrier delays, disruptions due to weather, or other delivery issues beyond our control.


    All shipments are processed on an EX-WORKS (EXW) basis from Heathrow Scientific’s facility. Risk of loss passes to the customer once the product is picked up by the carrier.

    Return Policy

    Should you need to return a Heathrow Scientific product, you must start the process with Blue Tiger Scientific. We will then work directly with Heathrow Scientific to facilitate your return, ensuring you obtain the necessary Return Goods Authorization (RGA) number.

    For domestic orders, products must be returned within 30 days of the order shipment date.

    All returns must include a valid RGA number obtained from Blue Tiger Scientific. If the product isn't received within the stipulated period, the RGA number will be voided. Any item received without a valid RGA number will be returned to the sender.

    Damaged or Missing Goods

    To ensure eligibility for a replacement or refund, all claims for damaged or missing items must be reported within 24 hours of delivery. Failure to report within this timeframe may void your claim due to carrier claim limitations.

    Returns Due to Customer Error or Change of Mind

    If you ordered the wrong product or simply changed your mind:

    The refund is the purchase price less a 20% restocking fee and less the original shipping costs. The product must be unused, in its original, unopened packaging and in resalable condition.

    Once Heathrow Scientific receives the returned product and verifies its condition, a credit will typically be issued to your original payment method within approximately 3 weeks.

    Non-Returnable Items

    Please note the following are non-returnable under any circumstances:

    Items missing accessories, manuals, or packaging will be rejected.

    Products classified as hazardous cannot be returned. Certain items are made to order and are not eligible for return or refund.

    Warranty Information & Registration

    All warranty claims and product registration are handled directly by Heathrow Scientific.

    For warranty details or to register your product, visit Heathrow Scientific’s Warranty Information & Registration page.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Serialized Encapsulated Glass Thermometers

Temperature Range: -30 to 120°F
Temperature Resolution: 2°F
Immersion Type: Total
Authorized Dealer

Choose an encapsulated thermometer for your bath

When a glass thermometer is used over a sample, the coating and the immersion mark answer different questions. The FEP sleeve is designed to retain broken glass and fill if the instrument breaks. The immersion type tells you how much of the stem belongs in the medium for a reading.

Representative VEE GEE FEP-encapsulated thermometer shown full length
Representative photograph of the unarmored, FEP-encapsulated family. Use the model row—not the photographed markings—to choose the scale and immersion type.

Match the immersion mark and the vessel

Same range, different working depth

For a −20 to 110°C bath, 80707E and 80907E both have 1°C marks. Use the total-immersion 80707E when the procedure immerses the bulb and liquid column up to the reading. Choose 80907E when the bath surface must meet the partial-immersion line.

Allow room for the longer Fahrenheit pair

The 30 to 220°F models are 15.38 inches long, compared with 12 inches for the other ranges. Check clearance around the vessel and clamp before choosing 80704E or 80904E. Overall length is not a specified immersion depth.

Buyer FAQs

What does the FEP coating do if the thermometer breaks?

The coating is designed to retain the glass fragments and liquid fill. It does not make the instrument unbreakable. If damage is suspected, remove it from service and follow your facility’s procedure for handling the instrument and any affected sample.

Can I substitute a partial-immersion model with the same range?

Not on the basis of range alone. Total immersion and partial immersion place different lengths of the liquid column in the medium. Match the designation in the method; for a partial-immersion instrument, look for the line on the actual stem.

Which models cover readings below −20°C?

80706E (total) and 80906E (partial) reach −35°C, but stop at 50°C. The −20 to 110°C and −20 to 150°C pairs reach higher temperatures, but neither covers the colder interval.

Which Fahrenheit model fits a 30 to 220°F procedure?

Choose 80704E for total immersion or 80904E for partial immersion. Both have 2°F divisions and a 15.38-inch overall length. If clearance is limited, do not assume that a shorter model with an overlapping range meets the procedure.

Is each thermometer marked in both Celsius and Fahrenheit?

No. The catalog number specifies one scale: 1°C divisions on the Celsius models or 2°F divisions on the Fahrenheit models. Select the units your procedure records. The family photograph is not a scale reference for every model.

Does a serial number establish calibration?

The serial number identifies the individual instrument in your equipment log. It does not, by itself, supply calibration results or a certificate. Confirm any required certificate, test points or traceability before ordering.

What is included, and is there a metal guard?

Each selected catalog number supplies one FEP-encapsulated glass thermometer. These E-suffix models have no metal armor. If your procedure specifies a guard, do not substitute this family simply because the range and graduations match.

Use this text to share information about your product.

Use this text to share information about your product.

Use this text to share information about your product.

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.