Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Scilogex 300002 Portable Dry Ice Maker – CGA-320 Stainless Steel Dewar Flask w Lid Clamps & Portable Dry Ice Maker Laboratory Dry Ice Makers Scilogex
Scilogex 300002 Portable Dry Ice Maker – CGA-320 Portable Dry Ice Maker Laboratory Dry Ice Makers Scilogex
Scilogex 300002 Portable Dry Ice Maker – CGA-320 Stainless Steel Dewar Flask w Lid Clamps & Portable Dry Ice Maker Laboratory Dry Ice Makers Scilogex
Scilogex 300002 Portable Dry Ice Maker – CGA-320 Portable Dry Ice Maker Laboratory Dry Ice Makers Scilogex

Scilogex 300002 Portable Dry Ice Maker – CGA-320

$1,728.00

    Make fresh dry ice when your lab needs it—without an electrical outlet. The Scilogex 300002 turns liquid CO₂ into approximately 1 kg (2.2 lb) blocks for on-demand research cooling.

    • North American CGA-320 connection; liquid CO₂ cylinder with internal siphon required separately.
    • Steel feed hose and pressure gauge included; typical cycles about 1–2 minutes after initial cooldown.
    • Choose maker only or the maker + SS333 4.5 L Dewar package.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

ON-DEMAND COOLING FOR THE RESEARCH LAB

Scilogex 300002 Portable Dry Ice Maker

Make a fresh block when your experiment needs it—not when a delivery arrives.

Turn liquid CO₂ into an approximately 1 kg (2.2 lb) dry ice block without an electrical outlet. This North American model uses a CGA-320 connection and a separately supplied liquid-withdrawal CO₂ cylinder with an internal siphon tube.

Scilogex 300002 dry ice maker with steel feed hose and pressure gauge
Actual Scilogex dry ice maker, feed hose and pressure gauge. CO₂ cylinder is not included.
~1 kg / 2.2 lb
Nominal dry ice block per cycle
No electricity
Powered by liquid CO₂ expansion
CGA-320
North American cylinder connection

Why make dry ice at the point of use?

For labs that use dry ice in small, intermittent batches, timing matters as much as quantity. The Scilogex portable dry ice maker lets you prepare a block close to the time of use instead of planning every experiment around purchased dry ice. It is a batch block maker—not a continuous industrial pelletizer.

Match production to the task

Make individual blocks for a planned experiment, cooling setup or packing session rather than automatically ordering a larger quantity.

Choose the work area—not the outlet

The maker needs no mains power. Place it on a stable, level surface in a suitable well-ventilated work area with a correctly supplied CO₂ cylinder.

Plan with real operating costs

Compare your local liquid CO₂ refill cost and expected block yield with delivered dry ice, delivery charges and the amount you actually use. Savings depend on your workflow.

Concept diagram: liquid CO2 is drawn from a cylinder through an internal siphon tube, not through a siphon in the hose
Original explanatory diagram based on the operating manual. The liquid pickup tube is part of the cylinder; your gas supplier must provide the correct cylinder.

What CO₂ cylinder does this dry ice maker need?

It requires a liquid CO₂ cylinder equipped with an internal siphon tube and the correct CGA-320 valve connection. The siphon draws liquid from inside the cylinder. A standard gas-withdrawal cylinder is not a substitute, even if its outlet looks familiar.

Before you order, confirm four things

  • Your gas supplier can provide a liquid-withdrawal CO₂ cylinder with a built-in siphon tube.
  • The cylinder valve matches the North American CGA-320 connection—not the international BS341 version.
  • You have a stable, level operating surface and adequate ventilation for escaping CO₂ gas.
  • Protective cryogenic gloves and suitable dry ice storage are available separately.

Ask your gas supplier for: a liquid CO₂ cylinder with an internal siphon tube and CGA-320 valve. Cylinder supply and refills are separate from the dry ice maker.

Which package should I choose?

Both options use the North American dry ice maker. Choose based on whether you already have a suitable Dewar for handling and storage. The CO₂ cylinder is not included with either package.

Maker only

Order code: 300002

Scilogex 300002 dry ice maker with steel feed hose and pressure gauge
Maker-only option; Dewar and CO₂ cylinder are separate.

For labs with an existing suitable dry ice storage setup.

  • Portable dry ice maker
  • Steel feed hose and pressure gauge
  • CGA-320 cylinder connection; operating instructions
View this package in the selector above →

Maker + SS333 Dewar package

Order code: 300002SS333

Scilogex portable dry ice maker alongside the SS333 stainless-steel-cased Dewar; Dewar package option
Dewar is included only with the maker + Dewar package.

For labs adding a matching storage component to the purchase.

  • Portable dry ice maker with hose and gauge
  • SS333 4.5 L stainless-steel-cased Dewar
  • Insulated, vented lid with lid clamps; borosilicate glass inner vessel
View this package in the selector above →

Choose the Dewar by construction, not its exterior: SS333 has a stainless steel outer case and a borosilicate glass inner vessel. It is not an all-stainless-steel vessel. The vented lid must remain able to release gas; never store dry ice in an airtight container.

How does the Scilogex portable dry ice maker work?

As liquid CO₂ expands into the maker, part of it forms carbon dioxide snow. The snow collects against the filtered walls and builds into a solid block while CO₂ gas escapes. The photos below show the actual Scilogex equipment; use the operating manual for setup, valve control and handling instructions.

Scilogex supplied hose connector and pressure gauge, shown disconnected
Supplied hose-end connection and gauge, shown disconnected.

1. Confirm the liquid supply

Match the hose connection to the correct siphon-equipped liquid CO₂ cylinder. Inspect and connect the equipment as directed in the manual.

Scilogex operating photograph of the pressure gauge at a liquid CO2 cylinder
Manufacturer operating photograph of the cylinder-side pressure gauge.

2. Monitor the gauge

Control the liquid supply according to the operating instructions. Increasing flow indiscriminately can waste CO₂; the gauge is there to guide operation.

Scilogex operating photograph of a dry ice block forming inside the maker
The filtered maker allows CO₂ gas to escape as the block forms.

3. Let the block form

The initial cycles cool the box and feed pipe. Follow the manual’s completion cues and close the cylinder valve before opening the maker.

Scilogex operating photograph of the opened maker and formed dry ice block
Opened maker and formed dry ice block in Scilogex’s operating photograph.

4. Remove and use the block

Release the latches and remove the block using suitable protective gloves. Handle the frozen feed hose carefully and follow the manual between cycles.

How much dry ice can I make?

Each block is nominally 1 kg (approximately 2.2 lb), with a published weight tolerance of ±10%. The nominal block dimensions are 180 × 110 × 80 mm—about 7.1 × 4.3 × 3.1 inches.

Plan around roughly 1–2 minutes per block under suitable conditions. The first one or two blocks take longer while the maker and feed pipe cool. Ambient temperature and the condition of the CO₂ supply affect both cycle time and yield.

Scilogex gives a typical yield of 5–6 blocks from a 34 kg (approximately 75 lb) liquid CO₂ cylinder at room temperature. Not all of the cylinder contents become solid dry ice. Use that yield as a planning reference, not a guaranteed production rate.

Need uniform pellets or continuous output? This unit forms blocks. It is not a pellet extruder, a dry ice blasting machine or a high-throughput production system.

Nominal dry ice block dimensions: 180 by 110 by 80 mm; approximately 1 kg or 2.2 lb; illustrative diagram
Original illustrative size guide based on the manufacturer’s nominal block dimensions. This is not a calibrated photograph of a production block.

Where does on-demand dry ice fit in a research lab?

Sample cooling and preparation

Prepare dry ice for research sample-cooling workflows and for freezing samples before suitable grinding or pulverization procedures.

Low-temperature experiments

Supply dry ice for protocol-appropriate cooling baths or cold traps. Choose the rest of the setup for your experiment; the maker is not itself a cold trap.

Packing and local handling

Make dry ice near the time it is needed for suitable research-material packaging and short-term cooling. Packaging, ventilation and transport requirements still apply.

Safe-use essentials: operate only in a well-ventilated area on a level supporting surface; never suspend the maker from its hose. CO₂ gas can cause suffocation and dry ice can cause frostbite. Use protective cryogenic gloves, keep storage vented and follow the supplied manual and your laboratory’s safety procedures. For laboratory and research use; no clinical-performance claims are made.

Complete the cooling workflow

Already have the maker and need storage separately? Compare the Scilogex stainless-steel-cased Dewars with vented lids and clamps, including the SS333 4.5 L model. For glass-free vessel requirements, review the construction and dimensions of the all-stainless-steel Dewar range; those vessels are sold without lids and are alternative storage choices, not automatic package substitutions.

Explore cryogenic storage products for the rest of your workflow. Select storage for the actual material, working dimensions and handling procedure—not capacity alone.

Frequently Asked Questions

What type of CO₂ cylinder is required?

Use a liquid CO₂ cylinder with a built-in siphon tube and a CGA-320 connection for this North American model. The siphon is inside the cylinder and draws liquid, not just gas. Confirm the cylinder specification with your gas supplier before purchasing.

How long does it take to make a dry ice block?

Allow roughly 1–2 minutes per block under suitable conditions. Scilogex’s manual explains that the first one or two blocks take longer while the box and feed pipe cool. Temperature, liquid CO₂ supply and operation affect the result.

How large and heavy is the dry ice block?

The nominal block weighs 1 kg (about 2.2 lb), with a published tolerance of ±10%. Its nominal dimensions are 180 × 110 × 80 mm, approximately 7.1 × 4.3 × 3.1 inches.

How many blocks will a 75 lb CO₂ cylinder produce?

Scilogex lists 5–6 blocks from a 34 kg (about 75 lb) liquid CO₂ cylinder at room temperature. Yield varies with temperature and supply conditions; the full cylinder mass does not convert into dry ice.

Does the maker need electricity or come with a CO₂ cylinder?

It needs no electrical power. The maker is supplied with a steel feed hose and pressure gauge. The correct liquid CO₂ cylinder, CO₂ refills and protective gloves are separate. A Dewar is included only when you select the maker + SS333 Dewar package.

What is the difference between 300002 and 300002SS333?

300002 is the North American maker-only option. The 300002SS333 package adds an SS333 4.5 L Dewar with a stainless steel case, borosilicate glass inner vessel and vented lid with clamps. Both options still need a separately supplied siphon-equipped liquid CO₂ cylinder.

Is this a dry ice pellet maker or a water ice machine?

No. It converts liquid carbon dioxide into solid dry ice blocks. It does not make water ice or extrude uniform pellets, and it is not a continuous industrial pellet-production system.

Is the North American CGA-320 version the same as the international version?

No. This page is for the North American CGA-320 connection. Scilogex also lists an international model with a BS341 connection. Verify your cylinder valve with your gas supplier rather than assuming the connections are interchangeable.

    SpecificationDetails
    BrandScilogex
    ProductPortable Dry Ice Maker / DILVAC dry ice block maker
    Maker catalog number300002
    Production formatIndividual dry ice blocks
    Nominal block weight1 kg ±10% (approximately 2.2 lb)
    Nominal block size180 × 110 × 80 mm (approximately 7.1 × 4.3 × 3.1 in)
    Maker box size225 × 160 × 160 mm (approximately 8.9 × 6.3 × 6.3 in)
    Typical cycle timeApproximately 1–2 minutes; first one or two blocks take longer while the box and feed pipe cool
    CO₂ supply requiredLiquid CO₂ cylinder with internal siphon tube; supplied separately
    Cylinder connectionCGA-320, North American version
    Typical cylinder yield5–6 blocks per 34 kg (approximately 75 lb) liquid CO₂ cylinder at room temperature; conditions affect yield
    Electrical requirementNo electrical power required
    Included with makerSteel feed hose, pressure gauge and operating instructions
    Operating locationLevel supporting surface in a well-ventilated area
    Separate requirementsSuitable liquid CO₂ cylinder and refills, protective gloves, suitable dry ice storage

    Ordering Information

    SpecificationDetails
    300002 — Maker onlyOne North American dry ice maker with steel feed hose, pressure gauge and CGA-320 connection. CO₂ cylinder and Dewar are separate.
    300002SS333 — Maker + DewarDry ice maker plus SS333 4.5 L Dewar: stainless steel outer case, borosilicate glass inner vessel, vented lid and lid clamps. CO₂ cylinder is separate.

    Output values are nominal and depend on operating conditions. Read the operating manual before use; select your package using the product selector above.

    Shipping, Returns & Manufacturer Support

    Blue Tiger Scientific is your reseller and first point of contact for order, return and support questions. CO₂ cylinders, refills and protective gloves are not included. The Dewar is included only with the maker + SS333 package.

    Shipping & delivery

    Availability, dispatch timing and shipping charges are confirmed for your order. Contact Blue Tiger Scientific before ordering if you have a fixed project deadline or need destination-specific shipping information.

    Returns through Blue Tiger Scientific

    Contact Blue Tiger Scientific to request authorization before returning anything. Eligible returns must be requested within 14 days of the purchase date and must be new and unused, with the original packaging, labels and included items. Any longer exception requires written Scilogex approval coordinated through Blue Tiger Scientific and is not guaranteed.

    Return shipping & inspection

    Authorized returns are subject to manufacturer inspection and approval. Return shipping is the customer’s responsibility unless otherwise agreed in writing. Applicable charges or deductions are confirmed during authorization. Use a trackable, appropriately insured service, and do not ship to the manufacturer without the return instructions provided through Blue Tiger Scientific.

    Manufacturer warranty & service

    Scilogex handles manufacturer warranty assessment, repair and service; Blue Tiger Scientific coordinates the request. Contact us to confirm the applicable warranty period for your exact configuration. Coverage is subject to Scilogex’s terms and proper installation, use and handling. Unauthorized repair, modification, misuse or damage may invalidate coverage.

    Damage, defects & safe returns

    Report shipping damage or a suspected defect to Blue Tiger Scientific with your order number, product details and photographs where appropriate. Follow the authorization and decontamination instructions before shipping equipment. Do not return contaminated materials or a CO₂ cylinder with the equipment.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart