Give us a call at (833)928-4437

Polystyrene cuvettes provide a 10 mm light path for measurements from 340 to 800 nm. Four cuvette configurations and two clearly labeled cap-only options let you match volume and opening shape.
10 mm
Light path
340–800 nm
Specified wavelength range
4 cuvettes
1.5, 2.5 or 4.5 mL
Caps separate
500 per cap pack
Visible-range optics
Optically clear polystyrene for the specified 340–800 nm range.
Standard exterior
Cuvettes measure 12.5 × 12.5 × 45 mm.
Opening choices
Round-opening and square-opening options use different matching caps.
Separate ordering units
Cuvettes: 1000 per pack; caps only: 500 per pack.

Select a cuvette or a cap-only option deliberately. A 1000-cuvette pack needs two 500-cap packs for one cap per cuvette. Verify instrument holder geometry, wavelength and sample compatibility.
S4100-1
Configuration: Spectrophotometer Cuvette, PS, 1.5mL semi-micro, round opening, 10mm light path, 340-800nm range, 2 optical sides, 10 trays of 100, 1000/cs
Order unit: 1000 per pack
S4100-2
Configuration: Spectrophotometer Cuvette, PS, 2.5mL semi-micro, round opening, 10mm light path, 340-800nm range, 2 optical sides, 10 trays of 100, 1000/cs
Order unit: 1000 per pack
S4100-3
Configuration: Spectrophotometer Cuvette, PS, 1.5mL semi-micro, square opening, 10mm light path, 340-800nm range, 2 optical sides, 10 trays of 100, 1000/cs
Order unit: 1000 per pack
S4100-4
Configuration: Spectrophotometer Cuvette, PS, 4.5mL macro, square opening, 10mm light path, 340-800nm range, 2 optical sides, 10 trays of 100, 1000/cs
Order unit: 1000 per pack
S4100-5
Configuration: CAPS ONLY: Cuvette Cap / Plug, round, yellow, 500/pk
Order unit: 500 per pack
S4100-6
Configuration: CAPS ONLY: Cuvette Cap / Plug, square, blue, 500/pk
Order unit: 500 per pack
Select a cuvette or a cap-only option deliberately. A 1000-cuvette pack needs two 500-cap packs for one cap per cuvette. Verify instrument holder geometry, wavelength and sample compatibility.
No. Caps are ordered separately. S4100-5 and S4100-6 are cap-only packs with 500 caps each, not cuvette packs.
Round S4100-5 fits S4100-1 and S4100-2. Square S4100-6 fits S4100-3 and S4100-4.
S4100-1: 1.5 mL round opening; S4100-2: 2.5 mL round; S4100-3: 1.5 mL square; S4100-4: 4.5 mL square.
No. Their specified range is 340–800 nm. They are not represented as equivalent to quartz cuvettes or suitable for 260 nm nucleic-acid measurements.
Examples include Spectronic 200, 20/20D and Educator, Genesys, Carolina and Accuris SmartDrop models. Verify the exact holder and measurement method; this is not OEM status or universal compatibility.
The light path is 10 mm and exterior dimensions are 12.5 × 12.5 × 45 mm, with two optical sides.
Each cuvette option contains ten trays of 100, totaling 1000. Cap-only options contain 500 caps. The workbook sellable UOM is a pack.
No universal chemical compatibility is claimed. Confirm polystyrene compatibility with the sample, solvent, temperature and exposure time before use.
Use this text to share information about your product.
Use this text to share information about your product.
Use this text to share information about your product.