Skip to content
Milwaukee MW605 MAX Waterproof Galvanic Dissolved Oxygen Meter With Automatic Calibration Milwaukee Instruments
Milwaukee MW605 MAX Waterproof Galvanic Dissolved Oxygen Meter With Automatic Calibration Milwaukee Instruments
Milwaukee MW605 MAX Waterproof Galvanic Dissolved Oxygen Meter With Automatic Calibration Milwaukee Instruments
Milwaukee MW605 MAX Waterproof Galvanic Dissolved Oxygen Meter With Automatic Calibration Milwaukee Instruments
Milwaukee MW605 MAX Waterproof Galvanic Dissolved Oxygen Meter With Automatic Calibration Milwaukee Instruments
Milwaukee MW605 MAX Waterproof Galvanic Dissolved Oxygen Meter With Automatic Calibration Milwaukee Instruments
Milwaukee MW605 MAX Waterproof Galvanic Dissolved Oxygen Meter With Automatic Calibration Milwaukee Instruments
Milwaukee MW605 MAX Waterproof Galvanic Dissolved Oxygen Meter With Automatic Calibration Milwaukee Instruments

Milwaukee MW605 MAX Waterproof Galvanic Dissolved Oxygen Meter With Automatic Calibration

$965.76

    SKU: MW605

    UPC: 810666003601

    MPN: MW605

    Range: 0.0 to 45.00 mg/L (ppm) O2 | % Saturation O2 0.0 to 300.0% | Temp. -20.0 to 120.0°C / -4.0 to 248.0°F

    Resolution: O2 0.01 mg/L (ppm) | % Saturation O2 0.1% | Temperature 0.1°C / 0.1°F

    Accuracy: O2 &plusmn1.5% of reading &plusmn1 digit| Temperature &plusmn0.4°C (&plusmn0.8°F)

    Calibration: One or Two % Saturation calibration points 0% (MA9070) and 100% (water saturated air)

    Manual: Milwaukee MW605 Manual

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b

Description

The Milwaukee MW605 MAX Galvanic Portable Waterproof Dissolved Oxygen meter is one of Milwaukee's most popular meters with its reliable and fast operation as well as its accuracy.

The Milwaukee MW605 MAX DO Meter is preferred by people looking for lab level accuracy without the cost. The Milwaukee DO Meter is popular with everyone from field biologists, educators, fish farmers, koi pond owners, water treatement plants and labs.

Design features

  • Fast, easy-to-read results with large digital LCD readout.
  • Galvanic probe means no conditioning time.
  • Repeatable, accuracy to ±1.5% of reading.
  • Water Proof IP67 Rated.
  • Lightweight and portable.
  • Simple 1 or 2 % saturation calibration points at 100% (water saturated air) and 0% (zero oxygen solution).
  • Dedicated GLP key to store and recall data on system status.
  • Available log space for up to 1000 records.
  • Logged data export via USB cable.
  • Altitude and Salinity compensation.
  • Automatic temperature compensation °F & °C.
  • Uses MA860 (included) reinforced Galvanic probe with an oxygen-permeable polytetrafluroethylene (PTFE) membrane sensor.
  • 2 O-rings MA861, membranes and one protective cap included.
  • Electrolyte MA9072S 30 mL
  • 10 feet probe cable for extra flexibility when testing.
  • 3 x 1.5 volt akaline AA battery (battery included) aprox. 200 hours of battery life with continuous use with low battery warning.

Care and Maintenance

Probe Maintenance:

The silver cathode should always be bright and untarnished. If it is tarnished or stained, the cathode should be cleaned gently witha lint-free cloth.

  • Rinse the probe with deionized or distilled water.
  • Replace the membrane cap using fresh electrolyte.
  • Recalibrate meter.

Membrane Maintenance:

  • For accurate and stable measurements, perfect condition of the membrane surface is needed. Protect the thin membrane from scratches, abrasion or contact with solids.
  • If no measurements are taken for a few hours, protect the membrane with the plastic protective cap.
  • If fouled, rinse it carefully with distilled or deionized water. If damaged, replace the membrane cap.

Note: Change the membrane every 8 weeks or more frequently if used in a specially fouling environment. Check and replace the electrolyte fill solution every 4 weeks.

Storage:

  • After taking measurements, switch the meter off and clean the probe before storage. When not in use the probe should be stored with the plastic cap on.

For short term storage, the probe can also be stored in a beaker of deionized water with the protective plastic cap removed.

For long term storage, the probe should be stored dry:

1. Disconnet the probe from the meter.

2. Unscrew the membrane cap.

3. Remove any electrolyte solution from the cap.

4. Rinse the probe anode/cathode assembly with distilleed water and blot dry.

5. Screw the membrane cap onto the probe until the membrane cap is hand tight.

    Specification Detail
    O 0.0 to 45.00 mg/L (ppm)
    O 0.0 to 300.0 % Saturation
    Range Temperature**: -20.0 to 120.0 °C (-4.0 to 248.0 °F)
    O 0.01 mg/L (ppm) / 0.1 % Saturation
    Temperature Resolution: 0.1 °C (0.1 °F)
    O ±1.5% of reading ± 1 digit
    Temperature Accuracy: ± 0.4 °C (±0.8 °F)
    Calibration: One or Two % saturation calibration points 0 % (MA9070) and 100 % (water saturated air)
    Temperature Compensation: Automatic, from 0.0 to 50.0°C (32.0 to 122.0 °F)
    Altitude compensation: -500 to 4,000 m (-1,640' to 13,123') with 100 m (328') resolution
    Salinity Compensation: Manual, from 0 to 40 g/L ( with 1 g/L resolution)
    Logging/Memory: Max. 1,000 log records (stored in up to 100 lots) / On Demand, 200 logs / On Stability, 200 logs / Interval logging, 1,000 logs
    PC Connectivity: 1 micro USB port
    Battery Type: 3 x 1.5V alkaline AA (included)
    Battery Life: Approx. 200 hours of use
    Environment: 0 to 50°C / 32 to 122°F; max RH 95%
    Dimensions Meter: 8 x 3.3 x 2.0 inches (200 x 85 x 50 mm)
    Dimensions Packaging: 14 x 12 x 6.0 inches (355.6 x 304.8 x 152.4 mm)
    Weight Meter: 0.57 lbs (260 g)
    Weight Packaged: 5.0 lbs (2.27 kg)
    Probe: MA860 Galvanic Probe included, 10' (3 meters)
    Temperature Range: 0.0 to 50.0°C / 32.0 to 122.0°F
    Temperature Sensor: Built in Thermistor
    Cathode: Silver
    Anode: Zinc
    Membranes: Oxygen permeable PTFE (2) included
    Connector Socket: DIN 7pins
    Body: PP, ABS, IP67 rating
    Cable: Jacket material: PP

    Milwaukee Instruments Warranty & Returns Policy
    (For Milwaukee Instruments ONLY – Not for Milwaukee Tools)

    How to Initiate a Return or Warranty Claim
    For products purchased through Blue Tiger Scientific, all returns must be initiated directly with us. However, all warranty claims must be handled directly through Milwaukee Instruments.

    Warranty Information
    Milwaukee Instruments products are manufactured to meet the highest quality standards and come with a limited warranty against defects in materials and workmanship. Products may be returned for repair or replacement at Milwaukee's discretion. Warranty is void if the product has been abused, misused, or repaired by unauthorized persons.

    To register your Milwaukee product, click here.

    Warranty Periods

    • Handheld testers, portable meters, and stationary monitors/controllers: 2 years
    • Bench meters: 3 years
    • PH600 pH Pen and similar versions: 1 year
    • Replaceable probes: 6 months

    Warranty begins on the original end-user purchase date or a maximum of 12 months from dealer purchase. Valid only with proper usage and maintenance. Service occurs at Milwaukee Instruments' North Carolina Technical Service Center.

    Note: Meters used in Kangen Water or “Negative ORP Water” applications are excluded from warranty coverage. Any warranty for these uses is null and void.

    Filing a Warranty Claim
    Contact Milwaukee Instruments Customer Service at (252) 443-3630 EST for an RMA number. Mark the RMA clearly on the box and ship prepaid. Improper packing can void the warranty.

    Return Policy (Blue Tiger Scientific)
    All purchases are final, but returns may be accepted under specific conditions:

    • Items must be in new condition with original packaging and contents.
    • Returns must be initiated within 14 days of purchase.
    • Subject to up to 30% restocking fee.
    • Customer pays all return shipping.
    • Initial shipping charges are non-refundable.

    Returns will be refused if packaging is damaged or contents are missing.

    Initiating a Return with Blue Tiger Scientific
    Contact Blue Tiger Scientific for an RMA and shipping instructions. Mark RMA clearly and pack securely to avoid transit damage. Shipping damage claims are the sender’s responsibility.

    Refunds, if eligible, will be processed within 5–10 business days. Credit card refunds may take longer to appear on your statement.

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY