Skip to content
Milwaukee MW306 MAX Waterproof EC/TDS/NaCl/Temp Logging Portable Meter Milwaukee Instruments
Milwaukee MW306 MAX Waterproof EC/TDS/NaCl/Temp Logging Portable Meter Milwaukee Instruments
Milwaukee MW306 MAX Waterproof EC/TDS/NaCl/Temp Logging Portable Meter Milwaukee Instruments
Milwaukee MW306 MAX Waterproof EC/TDS/NaCl/Temp Logging Portable Meter Milwaukee Instruments
Milwaukee MW306 MAX Waterproof EC/TDS/NaCl/Temp Logging Portable Meter Milwaukee Instruments
Milwaukee MW306 MAX Waterproof EC/TDS/NaCl/Temp Logging Portable Meter Milwaukee Instruments
Milwaukee MW306 MAX Waterproof EC/TDS/NaCl/Temp Logging Portable Meter Milwaukee Instruments
Milwaukee MW306 MAX Waterproof EC/TDS/NaCl/Temp Logging Portable Meter Milwaukee Instruments
Milwaukee MW306 MAX Waterproof EC/TDS/NaCl/Temp Logging Portable Meter Milwaukee Instruments
Milwaukee MW306 MAX Waterproof EC/TDS/NaCl/Temp Logging Portable Meter Milwaukee Instruments
Milwaukee MW306 MAX Waterproof EC/TDS/NaCl/Temp Logging Portable Meter Milwaukee Instruments
Milwaukee MW306 MAX Waterproof EC/TDS/NaCl/Temp Logging Portable Meter Milwaukee Instruments

Milwaukee MW306 MAX Waterproof EC/TDS/NaCl/Temp Logging Portable Meter

$821.04

    SKU: MW306

    UPC: 810666006287

    MPN: MW306

    Range EC: 0.00 to 29.99 uS/cm / 3.0 to 29.9 uS/cm | 30.0 to 299.9 uS/cm | 300 to 2999 uS/cm | 3.00 to 29.99 mS/cm | 30.0 to 200.0 mS/cm, up to 500.0 mS/cm (absolute conductivity)*

    Range TDS: 0.00 to 14.99 ppm (mg/L) | 15.0 to 149.9 ppm (mg/L) | 150 to 1499 ppm mg/L | 1.50 to 14.99 g/L | 15.0 to 100.0 g/L | up to 400.0 g/L (absolute TDS* with 0.80 factor)

    Range Salinity: 0.0 to 400.0 % Nacl | 2.00 to 42.00 PSU | 0.00 to 80.00 g/L

    Range Temperature: -20.0 to 120.0°C | -4.0 to 248.0°F

    Manual: Milwaukee MW306 Manual

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b

Lab Grade. High Performance. Automated. Tough.

The Milwaukee MW306 4-in-1 PRO EC/TDS/NaCl/Temp. Logging Portable Meter has won fans around the world with its reliable, fast and simple operation as well as its toughness and IP67 Waterproof rating. Accurate to ± 1% EC/TDS & Salinity with automatic or manual temperature compensation, and built in GLP key. Ideal for use by hydroponics, horticulture, labs, food processing, water treatment and many other applications with challenging EC/TDS/NaCL/Temp. measurement needs.

What People Are Saying

"Amazingly accurate, the best meter I have used so far."

"Very satisfied, very accurate, rugged device that calibrates easily."

"Rarely needs to be calibrated and gives perfect readings every time."

"Killer tool, good value."

"Logging data is easy-to-use and download."

"Love the GLP function."

"Easey to Clean."

Summary

The Milwaukee MW306 4-in-1 PRO EC/TDS/NaCl/Temp Portable Logging Meter is preferred by people testing samples in various applications. The easy-to-use logging feature allows data collection without messy notes and errors. From aquaculture and coral to hydroponic growers and farmers the MW306 is your meter for fast, accurate readings.

The Milwaukee PRO EC/TDS/NaCl/Temp. meter offers:

Accuracy

People choose the MW306 4-in-1 PRO EC/TDS/NaCl/Temp Portable Logging Meter to improve the accuracy of their testing program. With easy one point calibration and six standard buffer calibrations choices, the meter can be quickly calibrated to a high accuracy compared to other meters and it provides highly accurate temperature compensation readings. The MW306 meter is accurate to ± 1% of reading for EC/TDS and NaCL.

The meter comes with MA815D/1 conductivity probe with a built in temperature sensor allowing the meter to automatically adjust the EC/TD/NaCl reading for the effect of temperature (ATC).

The meter can also be used as a very accurate thermometer with accuracy +/-0.5°C (+/-0.9°F)

Toughness

The rugged meter is built to take knocks and is IP67 Waterproof rated.

Low maintenace

The MW306 PRO EC/TDS/NaCl/Temp Portable Logging Meter comes with the Milwaukee amplified MA815D/1 combination EC/Temp sensor. This is Milwaukee's top selling lab grade EC probe for a reason. Designed to be both low maintenance and able to withstand more challenging samples. The MA815D/1 is ideal for use in hydroponics, horticulture, aquaculture, labs, water treatment/conditioning and many other applications.

Design features

  • Fast easy to read results with large duel level digital LCD readout.
  • Extreme accuracy to 1% Of reading for EC/TDS/NaCl |+/- 0.5°C (+/-0.9°F).
  • Extended ranges for EC/TDS/NaCl.
  • Lightweight and portable, IP67 rated.
  • Simple easy-to-use logging and USB download functions ,manual or on demand up to 1,000 logs.
  • GLP data, date and time.
  • Different logging methods, manual log-on-demand or manual log-on-stability.
  • Easy measurement: just place the probe in the sample, gently stir and wait for the reading to stabilize.
  • Single cell factor calibration for EC/TDS automatic simple 1 point calibration.
  • Rugged low maintenance, high performance, easy-to-clean EC/TDS/NaCL/Temp probe.
  • Built in temperature sensor.
  • 3 x 1.5V Alkaline AA batteries with 200 hours battery life (included).
  • Built in Battery Error Prevention System (BEPS).
  • Auto-Ranging Feature for EC/TDS.
  • Auto-shut off feature to preserve battery energy.
  • Internal clock date to keep track of different time-dependent functions (calibration, timestamp,calibration time out).
  • 3 feet probe cables for extra flexibility when testing.
  • For various calibration solutions for MW306.

Care, Use and Cleaning

EC meters usually start performing poorly because of problems with the sediment on the conductivity probe's rings. The dirty rings on the probe can change impedance. Cleaning the rings is simple. Slide the plastic shield off and clean with DI water and soft cloth to keep your readings accurate.

Storage

When not in use, store the meter and probe in a safe area to avoid damage. The EC probe is stored dry. Remove batteries if not in use for a prolonged period to prevent battery compartment corrosion.

Calibration

The MW306 is easy 1 point calibration for ease-of-use and high accuracy with built in (ATC) feature. Calibrating regularly is best to keep your PRO MW306 4-in-1 meter accurate for all your readings.

Thank you for considering Milwaukee to help you take your results to the next level.

    Specification Detail
    EC Range: 0.00 to 29.99 µS/cm; 3.0 to 29.9 µS/cm; 30.0 to 299.9 µS/cm; 300 to 2999 µS/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm, absolute conductivity*
    TDS Range: 0.00 to 14.99 ppm (mg/L); 15.0 to 149.9 ppm (mg/L); 150 to 1499 ppm (mg/L); 1.50 to 14.99 g/L; 15.0 to 100.0 g/l; up to 400.0 g/L absolute TDS* (with 0.80 factor)
    Salinity Range: 0.0 to 400.0 %NaCl; 2.00 to 42.00 PSU; 0.00 to 80.00 g/L
    Temp. Range: -20.0 to 120.00 °C (-4.0 to 248.0 °F)
    EC Resolution: 0.01 µS/cm; 0.1 µS/cm; 1 µS/cm; 0.01 mS/cm; 0.1 mS/cm
    TDS Resolution: 0.01 ppm; 0.1 ppm; 1 ppm; 0.01 g/L; 0.1 g/L
    Salinity Resolution: 0.1 % NaCl / 0.01 PSU / 0.01 g/L
    Temperature Resolution: 0.1 °C / 0.1 °F
    Accuracy @ 25 °C / 77 °F
    EC/TDS Calibration: Single cell factor calibration, 6 standards: 84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm / one point offset: 0.00 µS/cm
    Salinity Calibration: one point with MA9066 salinity calibration solution
    Temperature Calibration: no temperature calibration
    Temperature Compensation: Automatic, -5.0 to 100.0°C (-23.0 to 212.0 °F) or manual from -20 to 120 °C (-4.0 to 248.0 °F) or NO TC without temperature compensation
    Conductivity temperature coefficient: 0.00 to 6.00 % / °C (EC and TDS only) | Default value: 1.90 % / °C
    TDS factor: 0.40 to 0.80 / Default value: 0.50
    EC Probe: MA815D/1, (4 ring)
    Temperature probe: Built-in temperature sensor
    Logging: Maximum 1,000 samples (max. 100 lots) / on demand, 200 samples; on stability, 200 samples / interval logging, 1000
    PC Connectivity: 1 micro USB port
    Battery type: 3 X 1.5V alkaline AA (included)
    Battery life: Approx. 200 hours of use
    Auto-off: Selectable 5, 10, 30, 60 min. or off
    Environment: 0 to 50°C / 32 to 122°F; max RH 95%
    Dimensions: 200 x 85 x 50 mm (7.9 x 3.3 x 2.0 inches)
    Casing: IP67
    Weight: .26 kg / 0.58 lbs (with battery)
    Warranty: 2 years, Meter
    * Absolute conductivity (or TDS) is the conductivity value without temperature compensation

    Milwaukee Instruments Warranty & Returns Policy
    (For Milwaukee Instruments ONLY – Not for Milwaukee Tools)

    How to Initiate a Return or Warranty Claim
    For products purchased through Blue Tiger Scientific, all returns must be initiated directly with us. However, all warranty claims must be handled directly through Milwaukee Instruments.

    Warranty Information
    Milwaukee Instruments products are manufactured to meet the highest quality standards and come with a limited warranty against defects in materials and workmanship. Products may be returned for repair or replacement at Milwaukee's discretion. Warranty is void if the product has been abused, misused, or repaired by unauthorized persons.

    To register your Milwaukee product, click here.

    Warranty Periods

    • Handheld testers, portable meters, and stationary monitors/controllers: 2 years
    • Bench meters: 3 years
    • PH600 pH Pen and similar versions: 1 year
    • Replaceable probes: 6 months

    Warranty begins on the original end-user purchase date or a maximum of 12 months from dealer purchase. Valid only with proper usage and maintenance. Service occurs at Milwaukee Instruments' North Carolina Technical Service Center.

    Note: Meters used in Kangen Water or “Negative ORP Water” applications are excluded from warranty coverage. Any warranty for these uses is null and void.

    Filing a Warranty Claim
    Contact Milwaukee Instruments Customer Service at (252) 443-3630 EST for an RMA number. Mark the RMA clearly on the box and ship prepaid. Improper packing can void the warranty.

    Return Policy (Blue Tiger Scientific)
    All purchases are final, but returns may be accepted under specific conditions:

    • Items must be in new condition with original packaging and contents.
    • Returns must be initiated within 14 days of purchase.
    • Subject to up to 30% restocking fee.
    • Customer pays all return shipping.
    • Initial shipping charges are non-refundable.

    Returns will be refused if packaging is damaged or contents are missing.

    Initiating a Return with Blue Tiger Scientific
    Contact Blue Tiger Scientific for an RMA and shipping instructions. Mark RMA clearly and pack securely to avoid transit damage. Shipping damage claims are the sender’s responsibility.

    Refunds, if eligible, will be processed within 5–10 business days. Credit card refunds may take longer to appear on your statement.

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)