Milwaukee MW190 MAX Dissolved Oxygen Bench Meter With Automatic Calibration

$1,269.90

    SKU: MW190US

    UPC: 8106660065286

    MPN: MW190US

    Range: 0.00 to 45.00 mg/L (ppm) O2 | 0.0 to 300.0 % O2| Temp. -5.0 to 55.0°C / 23.0 to 131.0°F

    Resolution: O2 0.01 mg/L (ppm) | 0.1% O2 | Temperature 0.1°C / 0.1°F

    Accuracy: O2 ±1.5% of Full Scale| Temperature ±0.4°C (±0.8°F)

    Calibration: Automatic, single (offset) or dual with slope 100% saturated air

    Manual: Milwaukee MW190 Manual

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b

Description

The Milwaukee MW190 MAX Bench Dissolved Oxygen meter is one of Milwaukee's most popular meters with its reliable and fast operation as well as its accuracy.

The Milwaukee MW190 MAX DO Bench Meter is preferred by people looking for lab level accuracy without the high cost. The Milwaukee DO Meter is popular with everyone from field biologists, educators, fish farmers, koi pond owners, education, water treatement plants and laboratories.

Design features

  • Fast, easy-to-read results with large digital LCD readout.
  • Repeatable, accuracy to ±1.5% FS.
  • Lightweight and has a small benchtop footprint.
  • Single offset or dual point slope with open air 100% saturation calibration.
  • Altitude and Salinity compensation.
  • Automatic temperature compensation.
  • Uses MA845 (included) reinforced polarographic probe with an oxygen-permeable polytetrafluroethylene (PTFE) membrane sensor
  • 5 o-rings, membranes and one protective cap included
  • 2 meter probe cable for extra flexibility when testing
  • Logging up to 50 samples.
  • 12 VDC power supply.
  • Easy RS232/USB opto-isolated
  • Complete with DO probe, initial calibration solutions and cables.
  • MA841 Replacement Membranes.

Care and Use

Probe Preparation Calibration Procedure

D.O. Probes are shipped dry: To hydrate the probe and prepare it for use, connect it to the meter and procede as follows:

1. Remove the the red and black cap. This cap is used for protection during shipping.

2. Wet the sensor by soaking the bottom 2.5 cm of the probe in electrolyte (MA9071) for 5 minutes.

3. Rinse the membrane (supplied with meter) with electrolyte solution while shaking it gently. Refill with clean electrolyte solution.

4. Gently tap the sides of the membrane with the fingertip to ensure that no air bubbles remain trapped. To avoid damaging the membrane, do not tap the membrane directly on the bottom.

5. Place the O-Ring (suppield with membranes) properly inside the membrane cap.

6. With the sensor facing down, screw the cap clockwise. Some electrolyte solution will overflow.

7. Turn the unit on use on/off key.

8. All LCD tags are displayed and a beep is heard while the instrument performs a test.

9. The "COND" message will be displayed for about 45 seconds to inform the user that the probe is in auto-conditioning mode (automatic polarization).

10. Once "COND" dissappears, the probe is polarized and the instrument can be calibrated.

2. Calibration Offset Procedure

1. Remove the clear protective cap.

2. Submerge the probe in MA9070 zero oxygen solution and stir for about 2-3 minutes.

3. Press CAL. The "WAIT" tag will blink on the LCD until reading is stable.

4. When the reading is stable, "READY" & "ACCEPT" tags are blinking. Press ACCEPT to confirm the "0.0%" D.O. calibration.

NOTE: When the instrument is not in use, place the CLEAR plastic cap (supplied with probe) over the membrane.

Extra tips

  • Watch for the membrane having wrinkles or stretch marks. If you see wrinkles, replace with a new membrane.
  • Always use fresh electrolyte solution (MA9071).
  • Always use MA841 membranes ONLY.
    Specification Detail
    O 0.00 to 45.00 mg/L O2 (ppm)
    % Saturation O 0.0 to 300.0% O2
    Temperature Range: -5.0 to 55.0 °C (23.0 to 131.0 °F)
    O 0.01 (ppm) mg/L
    % Saturation O 0.1%
    Temperature Resolution: 0.1 °C / 0.1 °F
    O ±1.5% Full Scale
    % Saturation O ± 1.5% Full Scale (@20 °C / 68 °F)
    Temperature Accuracy: ± 0.4 °C (±0.8 °F)
    Calibration DO: Automatic single (offset MA9070) or dual point with slope in 100% saturated air
    Calibration Temperature: 2 point at 0 and 50 °C (32.0 and 122.0 °F)
    Altitude compensation: 0 to 4000 m (13,120')
    Altitude Resolution: 100 m (328')
    Salinity Compensation: 0 to 40g/L
    Salinity Resolution: 1 g/L
    Temperature Compensation: Automatic, 0.0 to 50.0 °C (32.0 to 122.0 °F)
    Probe: MA840/2 polargraphic probe (included)
    Membranes: 5 included with O-Rings (included)
    Computer Interface: RS232/USB opto-isolated
    Power Supply: 12 VDC (included)
    Dimensions Meter: 230 x 160 x 95 mm (9.0 x 6.3 x 3.7 inches)
    Weight: 0.9 kg (2.0 lbs.)
    Environment: 0 to 50°C / 32 to 122°F; max RH 95%
    Warranty: 3 years (meter)

    Milwaukee Instruments Warranty & Returns Policy
    (For Milwaukee Instruments ONLY – Not for Milwaukee Tools)

    How to Initiate a Return or Warranty Claim
    For products purchased through Blue Tiger Scientific, all returns must be initiated directly with us. However, all warranty claims must be handled directly through Milwaukee Instruments.

    Warranty Information
    Milwaukee Instruments products are manufactured to meet the highest quality standards and come with a limited warranty against defects in materials and workmanship. Products may be returned for repair or replacement at Milwaukee's discretion. Warranty is void if the product has been abused, misused, or repaired by unauthorized persons.

    To register your Milwaukee product, click here.

    Warranty Periods

    • Handheld testers, portable meters, and stationary monitors/controllers: 2 years
    • Bench meters: 3 years
    • PH600 pH Pen and similar versions: 1 year
    • Replaceable probes: 6 months

    Warranty begins on the original end-user purchase date or a maximum of 12 months from dealer purchase. Valid only with proper usage and maintenance. Service occurs at Milwaukee Instruments' North Carolina Technical Service Center.

    Note: Meters used in Kangen Water or “Negative ORP Water” applications are excluded from warranty coverage. Any warranty for these uses is null and void.

    Filing a Warranty Claim
    Contact Milwaukee Instruments Customer Service at (252) 443-3630 EST for an RMA number. Mark the RMA clearly on the box and ship prepaid. Improper packing can void the warranty.

    Return Policy (Blue Tiger Scientific)
    All purchases are final, but returns may be accepted under specific conditions:

    • Items must be in new condition with original packaging and contents.
    • Returns must be initiated within 14 days of purchase.
    • Subject to up to 30% restocking fee.
    • Customer pays all return shipping.
    • Initial shipping charges are non-refundable.

    Returns will be refused if packaging is damaged or contents are missing.

    Initiating a Return with Blue Tiger Scientific
    Contact Blue Tiger Scientific for an RMA and shipping instructions. Mark RMA clearly and pack securely to avoid transit damage. Shipping damage claims are the sender’s responsibility.

    Refunds, if eligible, will be processed within 5–10 business days. Credit card refunds may take longer to appear on your statement.

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)