Skip to content
Milwaukee MA9071 Oxygen Electrolyte Solution Milwaukee Instruments
Milwaukee MA9071 Oxygen Electrolyte Solution Milwaukee Instruments

Milwaukee MA9071 Oxygen Electrolyte Solution

$48.72

    SKU: MA9071

    UPC: 810666009701

    MPN: MA9071

    Size: 230 mL

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b

Description

The MA9071 electrolyte fill solution is designed for Milwaukee's polarographic dissolved oxygen probe. A high quality electrolyte solution is crucial to the performance of your dissolved oxygen probe.

Design Features

Precise formulation

Factory mixed using reagent grade chemicals in a dedicated, temperature controlled environment.

Traceable

Product labeled with product code, lot number and expiration date.

Secure

Air tight bottle with tamper-proof seal.

Use and Care

“Open Air” Calibration Procedure for the MW600 Dissolved Oxygen Meter

1. Remove the membrane

Take the membrane off the end of the probe and dry the diode off.

2. Zero out the display

Connect the probe to the base unit and turn the unit on. Your display should read 0.0. If it does not, go to the position “0” screw on the front of the unit with the screw driver provided and through the access hole make the unit display read 0.0.

3. Fill the membrane

Go to the membrane and put the “O” ring inside the membrane on the shoulder at the base of the threads. Fill the membrane to just short of the “O” ring with MA9071 electrolyte solution. Be sure that there are no bubbles inside the membrane. (Air bubbles are the main cause of calibration failure)

4. Attach the membrane

Screw the membrane on to the probe.

5. Let stablize

Turn the meter on and hang the probe off the end of a table pointing down and let the unit display stabilize (this may take 5 to 15 minutes)

6. Adjust

Push down and hold the “Cal” button on the front face of the meter and with the screwdriver go to the front Cal position “100%” and make the display read 100.

You are now calibrated.

Extra tips

  • Watch for the membrane having wrinkles or stretch marks. If you see wrinkles, replace with a new membrane.
  • Always use fresh electrolyte solution (MA9071).

Watch this video to learn more about the Open Air Calibration method.

Thank you for considering Milwaukee to help you take your results to the next level.

    Specification Detail
    Package: Bottle
    Size:
    Quantity:
    Certificate of Analysis:

    Milwaukee Instruments Warranty & Returns Policy
    (For Milwaukee Instruments ONLY – Not for Milwaukee Tools)

    How to Initiate a Return or Warranty Claim
    For products purchased through Blue Tiger Scientific, all returns must be initiated directly with us. However, all warranty claims must be handled directly through Milwaukee Instruments.

    Warranty Information
    Milwaukee Instruments products are manufactured to meet the highest quality standards and come with a limited warranty against defects in materials and workmanship. Products may be returned for repair or replacement at Milwaukee's discretion. Warranty is void if the product has been abused, misused, or repaired by unauthorized persons.

    To register your Milwaukee product, click here.

    Warranty Periods

    • Handheld testers, portable meters, and stationary monitors/controllers: 2 years
    • Bench meters: 3 years
    • PH600 pH Pen and similar versions: 1 year
    • Replaceable probes: 6 months

    Warranty begins on the original end-user purchase date or a maximum of 12 months from dealer purchase. Valid only with proper usage and maintenance. Service occurs at Milwaukee Instruments' North Carolina Technical Service Center.

    Note: Meters used in Kangen Water or “Negative ORP Water” applications are excluded from warranty coverage. Any warranty for these uses is null and void.

    Filing a Warranty Claim
    Contact Milwaukee Instruments Customer Service at (252) 443-3630 EST for an RMA number. Mark the RMA clearly on the box and ship prepaid. Improper packing can void the warranty.

    Return Policy (Blue Tiger Scientific)
    All purchases are final, but returns may be accepted under specific conditions:

    • Items must be in new condition with original packaging and contents.
    • Returns must be initiated within 14 days of purchase.
    • Subject to up to 30% restocking fee.
    • Customer pays all return shipping.
    • Initial shipping charges are non-refundable.

    Returns will be refused if packaging is damaged or contents are missing.

    Initiating a Return with Blue Tiger Scientific
    Contact Blue Tiger Scientific for an RMA and shipping instructions. Mark RMA clearly and pack securely to avoid transit damage. Shipping damage claims are the sender’s responsibility.

    Refunds, if eligible, will be processed within 5–10 business days. Credit card refunds may take longer to appear on your statement.

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat