Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Winpact WP-COS CO2-Resistant Orbital Shaker Default Title Orbital Shakers Major Science
Winpact WP-COS CO2-Resistant Orbital Shaker Orbital Shakers Major Science
Winpact WP-COS CO2-Resistant Orbital Shaker Orbital Shakers Major Science
Winpact WP-COS CO2-Resistant Orbital Shaker Orbital Shakers Major Science
Winpact WP-COS CO2-Resistant Orbital Shaker Default Title Orbital Shakers Major Science
Winpact WP-COS CO2-Resistant Orbital Shaker Orbital Shakers Major Science
Winpact WP-COS CO2-Resistant Orbital Shaker Orbital Shakers Major Science
Winpact WP-COS CO2-Resistant Orbital Shaker Orbital Shakers Major Science

Winpact WP-COS CO2-Resistant Orbital Shaker

$3,372.00

    Controlled orbital shaking for a suitable CO2 incubator. A compact shaker base, separate 12-inch color touch controller and 20 mm orbit bring adjustable mixing to an incubator-based workflow. Confirm chamber fit and operating conditions before specifying your setup.

    • Set shaking speed from 1 to 300 rpm in 1 rpm steps, with continuous, timed and programmable modes.
    • Work with a 300 x 300 mm platform, a 20 mm orbital diameter and a manufacturer-rated maximum load of 5.2 kg.
    • Choose from listed flask holders, strip springs and mat options to suit your vessels and workflow.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

MAJOR SCIENCE · WINPACT · WP-COS

Add orbital motion to your incubator workflow

The Winpact WP-COS is an orbital shaker designed for use inside a suitable CO2 incubator. It is not an incubator and does not provide its own temperature, humidity or CO2 control. Major Science specifies corrosion-resistant construction to help protect internal components in high-CO2, humid conditions.

A brushless motor drives a 20 mm orbit across the 300 x 300 mm platform. The separate 12-inch color touch controller provides speed adjustment and continuous, timed or programmable operation, allowing you to select the run style that fits your protocol.

Winpact WP-COS orbital shaker base and separate 12-inch touch controller; flask and blue sticky pad are illustrative, not included accessories
Manufacturer WP-COS photograph. The flask, liquid and blue sticky pad illustrate a setup and are not the stated flat-mat package. Display settings are examples.

1 to 300 rpm

Shaking speed

20 mm

Orbital diameter

300 x 300 mm

Platform

5.2 kg

Maximum load

Why laboratories choose this format

Incubator-based mixing

Add a purpose-designed orbital shaker to a suitable host CO₂ incubator, instead of assuming an ordinary bench shaker is suitable.

Separate touch control

Use the 12-inch panel for continuous, timed or programmable operation. Agree controller placement and cable routing for the site.

Defined mixing format

A brushless motor, 20 mm orbit and 300 × 300 mm platform provide clear parameters for a fit and load review.

Which Winpact shaking format do I need?

SI-910

Refrigerated, non-CO₂ format

25 mm orbit; 10–300 rpm; 4–60°C at 23–25°C ambient. No CO₂ or humidity control specified.

SI-960

Refrigerated CO₂ format

50 mm orbit; 10–180 rpm; 4–60°C at 23–25°C ambient. 0.1–20% CO₂; 50–95% RH; HEPA optional.

WP-COS · Current model

Shaker for an existing incubator

20 mm orbit; 1–300 rpm; 300 × 300 mm platform. Requires a suitable host incubator for environmental control.

These are different instrument formats, not interchangeable configurations or upgrade promises. Select the complete system around the conditions your protocol requires.

Check the chamber before choosing the shaker

The base measures approximately 310 x 310 x 97 mm including the tray platform. Use these dimensions as the starting point for a fit check, then account for vessel height, holders, orbital movement, ventilation and cable routing. The published base dimensions are not a minimum incubator chamber specification.

Confirm the incubator shelf loading limit against the base mass of approximately 7.15 kg plus the planned load. The controller measures 320 x 102 x 246 mm and weighs approximately 4.65 kg. Controller placement, cable access and required clearances should be agreed for the installation.

Elevated manufacturer view of the WP-COS platform, shaker base and touch controller with an illustrative flask and optional blue pad
Manufacturer alternate view. Base dimensions do not include the clearance needed for your vessels, holders, movement and cable.
Manufacturer WP-COS touchscreen illustration with example speed and time settings; display values do not establish timer or program limits
Manufacturer interface illustration. Values shown are examples, not a published maximum timer range or program-step count.

Select speed and run mode at the touch panel

The 12-inch color touch panel supports continuous, timed and programmable modes. Shaking speed is adjustable from 1 to 300 rpm in 1 rpm steps, and the specification also lists a 0 rpm setting.

For protocols that depend on a particular timing range, sequence length or saved-program workflow, confirm those details before purchase. The public specification does not define program-step limits, stored recipe capacity or the full timer range.

Match vessel retention to your experiment

The 300 x 300 mm platform has a 316L top plate. Major Science lists strip springs, a 200 x 200 mm sticky pad, 300 x 300 mm dimpled and flat mats, and flask holders in nominal sizes from 50 to 2000 mL as accessories for this model.

Choose retention accessories around the actual vessel geometry, working load and intended speed. Holder size is not a claim about how many vessels fit on the platform or how much culture volume the shaker can process. Confirm the accessory arrangement rather than using photographs as a packing list.

Manufacturer WP-COS accessory diagram showing strip springs, sticky pad, dimpled mat, flat mat and flask holders; selected separately as required
Manufacturer accessory overview. The flat-mat platform is in the listed configuration; sticky pad, dimpled mat, springs and holders are separate selections.

Confirm the environmental operating envelope

The WP-COS is specifically described as a CO2-resistant orbital shaker for incubator use. The reviewed public manufacturer materials do not state numerical temperature, relative-humidity or CO2 concentration limits for this model.

Provide the proposed incubator model and operating conditions when confirming suitability. Cable length, feed-through compatibility, controller placement and any cleaning or decontamination requirements also need to be checked. Do not assume compatibility with every incubator or its sterilization cycle.

Specify the complete configuration

The listed WP-COS configuration combines the orbital shaker, 12-inch color touch controller and flat-mat platform. A blue sticky pad is a different retention option, not the stated flat-mat configuration.

Confirm the supplied cable and its length, the final platform assembly and any additional vessel-retention accessories when defining the order. An incubator, glassware, blue sticky pad and pictured flask holders are not part of that stated configuration.

Optional PPL-04-SI-SI-200-3 sticky pad detail from the WP-COS accessory diagram; different from the supplied flat-mat platform
Optional sticky pad PPL-04-SI-SI-200-3, 200 × 200 mm. This is not the flat-mat platform stated in the WP-COS ordering configuration.

A practical incubator fit check

1 · Space and access

Start with the approximately 310 × 310 × 97 mm base envelope, then add your vessel height, retaining hardware, motion clearance and access.

2 · Shelf and load

Check the host shelf rating for the approximately 7.15 kg base plus the planned load. The shaker maximum load is 5.2 kg.

3 · Conditions and cable

Confirm temperature, humidity, CO₂ conditions, cable reach and routing. Published base size does not establish a universal incubator fit.

Planning tip: A nominal 2000 mL holder size does not establish platform vessel count, culture working volume or compatibility with a particular incubator.

See the WP-COS manufacturer demonstration

Exact-model manufacturer demonstration. Any labware and optional retention accessories shown are illustrative. No additional timer, programming or environmental limits are inferred from the display.

Other laboratory workflows

Alternative format

MS-NOR-3001 anti-moisture orbital shaker

A different orbital format for a separately defined bench or chamber workflow. Review its lower published speed range and different load rating; it is not an integrated incubator or a like-for-like replacement.

Related workflow

MU-D01 digital peristaltic pump

Explore a separate liquid-transfer step. Tubing and flow requirements are selected independently; no mechanical, electrical or automated integration with this shaker is implied.

WP-COS buyer questions

Is the WP-COS an incubator?

No. It is an orbital shaker intended for use inside a suitable CO2 incubator. The incubator supplies the controlled environment; the WP-COS supplies the shaking motion.

Will it fit my CO2 incubator?

Fit must be checked for your chamber. The base is approximately 310 x 310 x 97 mm including the tray platform. Allow additional space for vessels, holders, orbital movement and cable routing, and check the shelf load limit against the approximately 7.15 kg base plus the planned load.

What speeds and orbit does it provide?

The WP-COS provides a 20 mm orbital diameter and shaking speeds from 1 to 300 rpm in 1 rpm steps. The manufacturer also lists a 0 rpm setting. Its published maximum load is 5.2 kg.

Does it support timed or programmed operation?

Yes. Continuous, timed and programmable modes are specified through the 12-inch color touch panel. The public specification does not confirm timer limits, program-step counts or stored-program capacity.

What comes with the WP-COS?

The listed WP-COS configuration includes the orbital shaker with a 12-inch color touch controller and flat-mat platform. Confirm the supplied cable and its length and any additional retention accessories on your quotation. The incubator, glassware, blue sticky pad and pictured holders are not established as included.

Which vessel accessories are available?

Listed options include 265 mm strip springs, a 200 x 200 mm sticky pad, 300 x 300 mm dimpled and flat mats, and flask holders sized from 50 to 2000 mL. Confirm fit for your specific vessels and intended speed. The listing does not establish vessel counts or total culture volume.

What temperature, humidity and CO2 levels can it withstand?

Numerical limits are not stated in the reviewed public manufacturer specifications. The manufacturer describes corrosion-resistant construction for high-CO2, humid conditions, but suitability for your operating conditions and any incubator decontamination cycle needs confirmation.

Is it the same product as the MS-NOR-3001 anti-moisture shaker?

No. The WP-COS is a separate Winpact model with a brushless motor, 12-inch touch controller and a stated 1 to 300 rpm shaking range. MS-NOR-3001 belongs to the MS orbital shaker range. Do not transfer package contents, capacities or environmental limits between these models.

    SpecificationDetail
    Manufacturer / rangeMajor Science / Winpact
    ModelWP-COS
    MotionOrbital
    Speed settings0; 1 to 300 rpm in 1 rpm steps
    Orbital diameter20 mm
    MotorBrushless motor
    Top plate material316L
    Platform dimensions, W x L300 × 300 mm
    Maximum load5.2 kg
    Controller12-inch color touch panel
    Operating modesContinuous / timed / programmable
    SupplyAC 100 to 240 V, 50/60 Hz
    Base dimensions, W x L x HApproximately 310 × 310 × 97 mm, including tray platform
    Controller dimensions, W x L x H320 × 102 × 246 mm
    Base mass, not shipping weightApproximately 7.15 kg
    Controller mass, not shipping weightApproximately 4.65 kg
    Listed supplied platformFlat-mat platform
    Environmental limitsConfirm the intended chamber temperature, RH and CO₂ conditions; no numerical limits are stated in the reviewed manufacturer specification.

    Ordering Information

    Order detailConfiguration
    Catalog numberWP-COS
    Product configurationWinpact WP-COS CO2-Resistant Orbital Shaker
    Supplied scopeWP-COS orbital shaker, 12-inch color touch controller and flat-mat platform. Confirm supplied cable and selected additional accessories.
    Packed shipping weightTo be confirmed for the selected order configuration. Instrument masses are not packed shipping weights.

    Additional and Replacement Accessories

    Select the actual vessel retention required. The accessory table does not specify supplied counts or platform flask capacity. MS-FLAT-30 is the listed flat-mat replacement option, not a blue sticky pad.

    Catalog numberAccessory
    MW-SPStrip springs, 265 mm, accessory pack of 2
    PPL-04-SI-SI-200-3Sticky pad, 200 × 200 mm
    MS-DIMPLED-30Dimpled mat, 300 × 300 mm
    MS-FLAT-30Non-slip rubber mat, 300 × 300 mm
    SI-200-0850 mL flask holder
    SI-200-09125 mL flask holder
    SI-200-10250 mL flask holder
    SI-200-11500 mL flask holder
    SI-200-121000 mL flask holder
    SI-200-132000 mL flask holder

    Ordering, shipping and product support

    Before ordering: Confirm WP-COS chamber fit, environmental conditions, controller placement, cable reach and selected vessel-retention accessories before ordering. The incubator and glassware are not included.

    Shipping: Blue Tiger Scientific arranges fulfillment through its suppliers. Confirm availability, dispatch timing, packed shipping weight and delivery arrangements before ordering. For heavy or stacked systems, agree freight, unloading, site access and installation responsibilities in advance. Shipping estimates are not guaranteed delivery dates.

    Returns: Start all return requests with Blue Tiger Scientific. Our published policy allows requests within 14 days of delivery unless product-specific terms state otherwise, subject to eligibility and approval. Do not ship anything before receiving an RMA and return instructions. Restocking and shipping charges may apply to approved returns. International returns are not permitted under our published policy.

    Manufacturer support: Contact Blue Tiger Scientific with your order number, model, serial number and a description of the issue for help coordinating support. Applicable manufacturer warranty terms and exclusions govern any warranty claim. We will confirm the process before equipment is sent for evaluation.

    Shipping Policy · Returns & Refunds Policy

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat