Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Major Science Orbital Shakers | MS-NOR-30 & MS-NOR-3001 Orbital Shaker Major Science
Major Science Orbital Shakers | MS-NOR-30 & MS-NOR-3001 Orbital Shaker Major Science
Major Science Orbital Shakers | MS-NOR-30 & MS-NOR-3001 Orbital Shaker Major Science
Major Science Orbital Shakers | MS-NOR-30 & MS-NOR-3001 Orbital Shaker Major Science
Major Science Orbital Shakers | MS-NOR-30 & MS-NOR-3001 Orbital Shaker Major Science
Major Science Orbital Shakers | MS-NOR-30 & MS-NOR-3001 Orbital Shaker Major Science
Major Science Orbital Shakers | MS-NOR-30 & MS-NOR-3001 Orbital Shaker Major Science
Major Science Orbital Shakers | MS-NOR-30 & MS-NOR-3001 Orbital Shaker Major Science
Major Science Orbital Shakers | MS-NOR-30 & MS-NOR-3001 Orbital Shaker Major Science
Major Science Orbital Shakers | MS-NOR-30 & MS-NOR-3001 Orbital Shaker Major Science
Major Science Orbital Shakers | MS-NOR-30 & MS-NOR-3001 Orbital Shaker Major Science
Major Science Orbital Shakers | MS-NOR-30 & MS-NOR-3001 Orbital Shaker Major Science
Major Science Orbital Shakers | MS-NOR-30 & MS-NOR-3001 Orbital Shaker Major Science
Major Science Orbital Shakers | MS-NOR-30 & MS-NOR-3001 Orbital Shaker Major Science
Major Science Orbital Shakers | MS-NOR-30 & MS-NOR-3001 Orbital Shaker Major Science
Major Science Orbital Shakers | MS-NOR-30 & MS-NOR-3001 Orbital Shaker Major Science

Major Science Orbital Shakers | MS-NOR-30 & MS-NOR-3001

$1,446.00

    Choose the motion and moisture protection your bench needs. Major Science MS-NOR orbital shakers combine digital control and a 30 × 30 cm platform, with standard MS-NOR-30 and anti-moisture MS-NOR-3001 options.

    • Choose standard MS-NOR-30 or anti-moisture MS-NOR-3001 for your working environment.
    • Set one-way orbital speed up to 200 rpm in 1 rpm increments, or use lower-speed alternating motion.
    • Start with the included 30 × 30 cm platform and flat non-slip mat; add vessel holders to suit your workflow.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

MAJOR SCIENCE · MS-NOR-30 / MS-NOR-3001

Orbital mixing that fits your daily workflow

From reagent mixing to routine sample agitation, the Major Science MS-NOR family brings adjustable orbital motion to a compact benchtop instrument. Digital controls, an LED display and a stepping motor let you set the speed and run time for each protocol.

Both MS-NOR-30 and MS-NOR-3001 provide a 30 × 30 cm platform, up to 10 kg loading capacity and continuous or timed operation. Choose the standard model for routine laboratory work, or the anti-moisture model when cold-room conditions make condensation management a priority.

Major Science MS-NOR-30 orbital-family reference shaker with optional strip springs and sample tubes
Manufacturer orbital-family photograph. Strip springs and sample tubes shown are optional/examples, not the supplied flat-mat package. Anti-moisture coating is not visible in this exterior view.

300 × 300 mm

Included platform with flat non-slip rubber mat.

Up to 200 rpm

Published overall speed range; follow mode-specific operating limits.

10 kg maximum

Published family load limit, not a per-tier allowance.

Which MS-NOR model do I need?

MS-NOR-30 · standard

Choose the standard orbital model for routine bench work. Supplied with the 300 × 300 mm platform and flat non-slip mat.

MS-NOR-3001 · anti-moisture

Adds coating to the electrical structure. Manufacturer names cold-room and CO2-incubation applications; confirm the intended chamber conditions, not a universal waterproof rating.

Use the model selector above to choose the actual catalog number. Both options share the published platform size, motion settings and 10 kg maximum load; the coating is the defining model distinction.

Two models, one familiar mixing platform

MS-NOR-30 is the standard orbital shaker. MS-NOR-3001 adds an anti-moisture coating to the electrical structure while retaining the same published motion, speed, platform size and loading capacity.

Major Science identifies MS-NOR-3001 for cold-room and CO2 incubation applications. Match the intended temperature, humidity and chamber conditions to the manufacturer's guidance before specifying it for an incubator.

Manufacturer concept illustration of MS-NOR-3001 anti-moisture electrical coating, not an interior photograph or waterproof enclosure rating
Manufacturer concept illustration of electrical coating for MS-NOR-3001. It is not an interior photograph, immersion rating or proof of unrestricted humidity/CO2 use.
Manufacturer MS-NOR-30 orbital-motion illustration with sample flask and optional holders
Manufacturer orbital-motion illustration. A 20 mm maximum stroke is specified; no diameter/radius is inferred from these arrows.

Choose the motion your protocol needs

Select continuous one-way orbital shaking or alternating clockwise and counter-clockwise motion. The published speed range is 0 to 200 rpm with 1 rpm adjustment, and maximum orbital stroke is 20 mm.

For alternating motion, set the travel between direction changes from 0.1 to 10 circles in 0.1-circle increments. Follow the current supplied instructions for mode-specific speed restrictions; do not assume every motion mode uses the full published speed range.

Time the run and hear when it finishes

Use continuous operation for open-ended mixing or set a timed run up to 9999 minutes. Digital microprocessor control and the LED display keep speed and timing settings accessible at the front of the instrument.

Timed operation ends with automatic shut-off and an audible signal. That combination helps manage repeatable mixing intervals without relying on a separate bench timer.

Actual manufacturer orbital-shaker bench photograph; optional retention mat and sample setup are not base-kit contents
Genuine manufacturer orbital-shaker bench photograph. Optional mat, vessels and sample setup shown are not standard package contents.
Manufacturer orbital-shaker 10 kg maximum-load graphic; not a per-tier or all-speed configuration guarantee
Manufacturer graphic of the 10 kg orbital-family maximum. Actual vessel arrangement, speed and second-tier use still require appropriate setup.

Plan a stable, practical vessel layout

The included 300 × 300 mm platform and flat non-slip rubber mat provide a working surface for compatible vessels. Both models have a published maximum loading capacity of 10 kg.

Distribute vessels evenly and secure them with accessories appropriate to their shape and the selected speed. An optional second platform adds another level, but the manufacturer notes that second-tier operation can change the maximum loading capacity.

Build the platform around your vessels

Optional accessories include flask holders, strip springs, a dimpled mat, a sticky pad, a universal adjustable platform and an additional stacking platform. These let you configure the shaker around the vessels you actually use instead of treating every sample format the same.

The orbital platform's published flask-holder capacities are 13 × 50 mL, 12 × 125 mL, 9 × 250 mL, 5 × 500 mL, 4 × 1000 mL or 1 × 2000 mL. These are alternative maximum layouts, not a set of holders supplied with the standard shaker.

MS-NOR orbital shaker with an optional sticky pad, sample vessel and microplate; these accessories and samples are separate
Optional sticky-pad application with vessels/microplate. Sticky pad and pictured samples are separate from the included flat-mat package.

Check the fit before you choose

Each model measures approximately 300 × 310 × 130 mm and weighs approximately 7 kg. Allow additional space for vessels, accessory platforms, access and ventilation when planning a bench or chamber position.

The published operating-temperature specification is ambient to 40°C, and the electrical specification is selectable 110 V or 220 V AC at 50/60 Hz. Confirm the required supply configuration and your intended operating environment when selecting the shaker.

Choose retention hardware, not just a flask volume

Optional flask-holder illustration for the MS-NOR orbital family; holders are not standard supplied quantities
Flask-holder illustration. The holder counts below are alternative layouts, not supplied quantities.
Vessel size Maximum alternative holder layout
50 mL 13 holders
125 mL 12 holders
250 mL 9 holders
500 mL 5 holders
1000 mL 4 holders
2000 mL 1 holder

These rows describe separate maximum layouts, not a mixed-load total or an included clamp set.

Optional MS-UP-30 universal adjustable platform, distinct from the included flat platform and standard flask-holder layouts
Optional MS-UP-30 adjustable platform, separately ordered. It is not the included flat platform.

One 2 L holder layout is not the same as the adjustable platform

The standard family holder chart lists one 2000 mL holder. The separate MS-UP-30 universal adjustable platform is listed for a maximum of two 2 L flasks. These are different retention arrangements, not conflicting included-capacity claims.

Select the platform and holder format around the actual vessel footprint and height, then secure and distribute the load for the intended speed. An optional stacking platform also needs its own capacity check.

What comes with the selected shaker?

  • Orbital shaker: One MS-NOR-30 or MS-NOR-3001, according to the selected model.
  • Platform: One 300 × 300 mm platform.
  • Flat non-slip rubber mat: Supplied with the standard platform; flask holders and other platform accessories are optional.
Manufacturer flat non-slip mat reference; a flat mat is included with the base platform
Flat non-slip mat reference. A flat mat is included; additional/replacement mats and retention accessories are separate selections.

Other mixing and transfer workflows

Alternative format: 3D rotating mixer

For a workflow calling for a different mixing motion, review the separate rotating-mixer format and confirm its container requirements. It is not a like-for-like orbital replacement.

View MS-3D-RM-US

Related workflow: digital peristaltic pump

For a separate liquid-transfer stage, explore the pump and its tubing-dependent flow selection. No mechanical or control compatibility with the shaker is implied.

View MU-D01

MS-NOR-30 / MS-NOR-3001 buyer questions

What is the difference between MS-NOR-30 and MS-NOR-3001?

MS-NOR-30 is the standard model. MS-NOR-3001 adds an anti-moisture coating to the electrical structure for cold-room applications. Both share the same published orbital motion, 0 to 200 rpm speed range, 30 × 30 cm platform and 10 kg maximum load.

Can MS-NOR-3001 be used in a cold room or CO2 incubator?

Major Science identifies MS-NOR-3001 for cold-room and CO2 incubation applications. Its anti-moisture coating is not a waterproof enclosure or an IP rating. Confirm the chamber temperature, humidity and condensation conditions: the public table states ambient to 40°C but gives no model-specific cold minimum or RH envelope.

What load can the MS-NOR orbital family carry, including a second tier?

Both models have a published maximum load of 10 kg on the 300 × 300 mm platform. Manufacturer guidance says capacity may change with an additional tier; it is not 10 kg per tier or a guaranteed 20 kg total. Balance and securely retain the actual vessel layout for the selected motion and speed.

Do MS-NOR-30 and MS-NOR-3001 alternate direction?

Both offer one-way orbital or alternating clockwise/counter-clockwise motion, with 0.1 to 10 circles between changes in 0.1-circle increments. The current table lists 0–200 rpm overall without a mode breakdown. A manufacturer-authored 2014 exact-model manual specifies two-direction operation below 100 rpm; check the current supplied instructions if alternating speed is essential to your method.

What is included with MS-NOR-30 or MS-NOR-3001?

The standard model description includes the selected orbital shaker, a 300 × 300 mm platform and a flat non-slip rubber mat. Flask holders, strip springs, dimpled mats, sticky pads, universal adjustable platforms and additional stacking platforms are optional.

How many flask holders fit the MS-NOR-30 or MS-NOR-3001 platform?

The manufacturer's orbital-platform capacities are 13 holders for 50 mL flasks, 12 for 125 mL, 9 for 250 mL, 5 for 500 mL, 4 for 1000 mL or 1 for 2000 mL. These are alternative layouts. The separate MS-UP-30 universal adjustable platform is listed for up to two 2 L flasks and should not be confused with the standard flask-holder layout.

Can MS-NOR-30 and MS-NOR-3001 run continuously or stop on a timer?

Both support continuous operation or timed runs up to 9999 minutes. An audible signal accompanies automatic shut-off at the end of a timed run.

Are MS-NOR-30 and MS-NOR-3001 available for 110 V and 220 V power?

Major Science lists both models with selectable 110 V / 220 V AC power at 50/60 Hz. Specify the supply required for your installation and confirm the unit's voltage configuration before connecting it.

    SpecificationDetail
    BrandMajor Science
    ModelsMS-NOR-30 standard; MS-NOR-3001 anti-moisture
    MotionOne-way orbital or alternating clockwise/counter-clockwise
    Speed range and increment0 to 200 rpm; 1 rpm increments
    Alternating-mode instructionsThe current table lists 0–200 rpm overall. A manufacturer-authored 2014 exact-model manual specifies two-direction operation below 100 rpm; check current supplied instructions for mode-specific use.
    Bidirectional travel setting0.1 to 10 circles; 0.1-circle increments
    Maximum orbital stroke20 mm
    Controller and displayDigital microprocessor controller; LED display
    Operation and timerContinuous or timed up to 9999 minutes, with alarm and automatic shut-off
    Maximum loading capacity10 kg (22.0 lb); capacity may change with a second-tier platform
    Platform dimensions, W x L300 × 300 mm (30 × 30 cm)
    Platform materialPainted iron metal
    Stacking platformSupported with optional additional platform
    Unit dimensions, W x L x HApproximately 300 × 310 × 130 mm
    Instrument weight, not packed shipping weightApproximately 7 kg (15.4 lb)
    ConstructionABS and painted iron metal
    MotorStepping motor
    Published operating temperatureAmbient to 40°C
    Electrical supply110 V / 220 V AC selectable; 50/60 Hz; 0.63 A
    Anti-moisture coatingMS-NOR-3001 only; applied to the electrical structure

    Ordering Information

    Catalog no.Configuration
    MS-NOR-30Standard orbital shaker; 300 × 300 mm platform and flat non-slip mat.
    MS-NOR-3001Anti-moisture electrical-coating model; 300 × 300 mm platform and flat non-slip mat.

    Included Components

    ComponentCommon supplied configuration
    Orbital shakerOne MS-NOR-30 or MS-NOR-3001, according to the selected model.
    PlatformOne 300 × 300 mm platform.
    Flat non-slip rubber matSupplied with the standard platform; flask holders and other platform accessories are optional.

    Additional and Replacement Accessories

    Optional accessories are separately ordered; photographs are not a packing list.

    Catalog no.Accessory
    MW-SPStrip springs; pack of two, 265 mm
    MS-P3030Additional 300 × 300 mm platform with flat mat and eight attachable 100 mm pillars
    MS-DIMPLED-30Optional 300 × 300 mm dimpled mat
    MS-FLAT-30Replacement flat non-slip 300 × 300 mm mat
    MS-UP-30Universal adjustable 300 × 300 mm platform; maximum two 2 L flasks
    PPL-04-SI-SI-200-3200 × 200 mm sticky pad
    SI-200-08 / -09 / -10Flask holders for 50 / 125 / 250 mL
    SI-200-11 / -12 / -13Flask holders for 500 / 1000 / 2000 mL

    Ordering, shipping and product support

    Before ordering: Confirm MS-NOR-30 versus MS-NOR-3001, the required electrical configuration and any vessel-retention accessories before ordering. For cold-room or CO2 chamber use, confirm the current model-specific environmental guidance with Blue Tiger Scientific and the manufacturer.

    Shipping: Blue Tiger Scientific arranges fulfillment through its suppliers. Availability and dispatch timing depend on the supplier. Shipping estimates are not guaranteed delivery dates; contact us before ordering for a time-critical experiment.

    Returns: Start all return requests with Blue Tiger Scientific. Our published policy allows requests within 14 days of delivery unless product-specific terms state otherwise, subject to eligibility and approval. Do not ship anything before receiving an RMA and return instructions. Restocking and shipping charges may apply to approved returns. International returns are not permitted under our published policy.

    Manufacturer support: Contact Blue Tiger Scientific with your order number, model, serial number and a description of the issue for help coordinating support. Applicable manufacturer warranty terms and exclusions govern any warranty claim. We will confirm the process before equipment is sent for evaluation.

    Shipping Policy · Returns & Refunds Policy

    These downloads are manufacturer catalogue/brochure literature, not the current operating manual. Use the supplied instructions for motion-mode limits, environmental setup and operation.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat