Winpact SI-960 CO2 Stackable Incubator Shaker Default Title Shaking Incubators Major Science
Winpact SI-960 CO2 Stackable Incubator Shaker Shaking Incubators Major Science
Winpact SI-960 CO2 Stackable Incubator Shaker Shaking Incubators Major Science
Winpact SI-960 CO2 Stackable Incubator Shaker Default Title Shaking Incubators Major Science
Winpact SI-960 CO2 Stackable Incubator Shaker Shaking Incubators Major Science
Winpact SI-960 CO2 Stackable Incubator Shaker Shaking Incubators Major Science

Winpact SI-910 Stackable Incubator Shaker

$17,605.00

    Refrigerated incubation with a 25 mm orbit and shaking to 300 rpm. Bring temperature-controlled shaking to a stackable format with a 91 × 50 cm slide-out platform and a 10-inch touchscreen.

    • 10 to 300 rpm shaking with a 25 mm orbit
    • 4 to 60°C temperature range at 23 to 25°C ambient
    • 91 × 50 cm slide-out platform and a 10-inch touchscreen

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

MAJOR SCIENCE · WINPACT · SI-910

Temperature-controlled shaking, with room to plan your load

The Winpact SI-910 combines refrigerated incubation with a 25 mm orbit and 10 to 300 rpm shaking. It is the non-CO₂ option in this stackable family, for workflows that do not require controlled chamber CO₂ or humidity.

The 91 × 50 cm slide-out platform and glide-up door support loading and access, while a 10-inch capacitive touchscreen provides the control interface. Define the flask layout and module arrangement to suit the work you plan to run.

Winpact SI-910 and SI-960 family reference showing a single incubator-shaker module; final configuration and pictured labware require confirmation
Manufacturer family reference showing a single-module arrangement. Final module count and accessories are defined for the order; labware shown is illustrative.

25 mm

Orbit diameter

300 rpm

Maximum specified speed

4 to 60°C

At 23 to 25°C ambient

91 × 50 cm

Platform size

Why laboratories choose this format

Access the working area

A slide-out platform, glide-up door and chamber illumination support loading and visual checks.

Control the run

A 10-inch capacitive touchscreen brings PID temperature control, a manually editable program and timer settings together.

Choose the right atmosphere

Specify the non-CO₂ SI-910 for workflows without controlled chamber CO₂ or humidity.

Which Winpact shaking format do I need?

SI-910 · Current model

Refrigerated, non-CO₂ format

25 mm orbit; 10–300 rpm; 4–60°C at 23–25°C ambient. No CO₂ or humidity control specified.

SI-960

Refrigerated CO₂ format

50 mm orbit; 10–180 rpm; 4–60°C at 23–25°C ambient. 0.1–20% CO₂; 50–95% RH; HEPA optional.

WP-COS

Shaker for an existing incubator

20 mm orbit; 1–300 rpm; 300 × 300 mm platform. Requires a suitable host incubator for environmental control.

These are different instrument formats, not interchangeable configurations or upgrade promises. Select the complete system around the conditions your protocol requires.

Choose the non-CO₂ configuration deliberately

SI-910 provides a 25 mm orbit and a 10 to 300 rpm shaking range without CO₂ or humidity control. If your protocol depends on a controlled CO₂ atmosphere, compare it with SI-960 rather than assuming those features can be added to SI-910.

Detail of the Winpact incubator-shaker family chamber and illustrative flask arrangement; flask and holder counts are not supplied quantities
Manufacturer family chamber detail. The listed layouts are alternative maximums, not supplied flasks or holders.

Plan the load, not just the flask count

The 91 × 50 cm slide-out platform gives you access to the working area without reaching to the back of the chamber. A glide-up door and internal illumination support routine loading and visual checks.

Manufacturer family capacity examples are 50 × 250 mL, 32 × 500 mL, 18 × 1000 mL or 15 × 2000 mL. These are alternative maximum layouts. Flask shape, retaining hardware and operating speed need to be checked together; the figures are not an included accessory list.

Nominal flask size Alternative family maximum
250 mL 50 flasks
500 mL 32 flasks
1000 mL 18 flasks
2000 mL 15 flasks

Set the run from a 10-inch touchscreen

The capacitive LCD touchscreen works with PID control, a manually editable program and a timer specified to 9999 minutes or 9999 hours. Servo-driven shaking and forced internal air circulation are shared features of the platform.

Temperature uniformity is specified as ±0.5°C at 37°C. The 4–60°C control range is stated at 23–25°C ambient; do not treat the broader operating ambient range as the test condition.

Blue Tiger Scientific specification schematic comparing SI-910 25 mm orbit and 10–300 rpm with SI-960 50 mm orbit and 10–180 rpm
Blue Tiger Scientific specification comparison, schematic only. The facts are also stated in HTML and the specifications tab.
Manufacturer Winpact stackable incubator-shaker family illustration with three modules; not a statement of supplied unit count
Manufacturer three-module installation illustration. A pictured stack is not a supplied module quantity or an approved installation drawing.

Define the configuration before installation

Choose the module count and labware arrangement around your workload and available space. Manufacturer photographs show possible configurations, not a promise that a pictured stack, its holders or labware is included. Your confirmed quotation must identify the supplied modules and accessories.

Specify 110 V or 220 V single-phase power and review the final stack arrangement, support hardware, floor loading and service clearances. The manufacturer lists 50/60 Hz and 1800 W for these refrigerated models. Confirm the electrical connection for each module rather than assuming a complete stack uses one supply.

Understand the UV function

SI-910 includes a UV germicidal lamp in the manufacturer specification. It is not the 90°C moist-heat or 180°C dry-heat model in this family. Use the manufacturer’s operating and cleaning procedure, and do not treat the listed UV feature as a validated sterility claim.

Typical application fit

Non-CO₂ cultivation

For temperature-controlled shaking workflows that do not require regulated CO₂ or humidity.

Parallel flask work

Configure one of the manufacturer-listed alternative vessel layouts around the actual flask geometry.

Space planning

Review stacked arrangements where increased module capacity is needed within a defined laboratory area.

A better starting point for your quotation

1 · Define the process

Specify the temperature, orbit, speed, atmosphere and vessel geometry required by your existing protocol.

2 · Define the configuration

Agree module count, holders, optional filtration and the actual supplied components.

3 · Define the installation

Confirm the current installation drawing, voltage, services, floor loading, freight and support responsibilities.

Planning tip: Maximum flask count is not a guarantee of working culture volume or full-speed operation with every vessel layout. Verify the actual loaded configuration.

Other laboratory workflows

Alternative format

MS-NOR-3001 anti-moisture orbital shaker

A different orbital format for a separately defined bench or chamber workflow. Review its lower published speed range and different load rating; it is not an integrated incubator or a like-for-like replacement.

Related workflow

MU-D01 digital peristaltic pump

Explore a separate liquid-transfer step. Tubing and flow requirements are selected independently; no mechanical, electrical or automated integration with this shaker is implied.

SI-910 buyer questions

What is the difference between SI-910 and SI-960?

SI-910 has a 25 mm orbit and a shaking range of 10 to 300 rpm, without CO₂ or humidity control. SI-960 has a 50 mm orbit, a 10 to 180 rpm range, CO₂ control and a specified humidity range. Both provide refrigerated incubation and a UV germicidal lamp.

What temperature range does SI-910 provide?

The specified range is 4 to 60°C at an ambient temperature of 23 to 25°C. Temperature uniformity is listed as ±0.5°C at 37°C. These are stated test conditions, not a guarantee of identical performance throughout the operating range.

How many flasks can the platform hold?

The family maximums are 50 × 250 mL, 32 × 500 mL, 18 × 1000 mL or 15 × 2000 mL. These are alternative loading layouts, not supplied flask or holder counts. Confirm the layout and permitted speed for your actual flask geometry and retaining accessories.

Does the product include the three-module stack shown?

The photographs do not establish the supplied quantity. Public manufacturer information does not confirm the module count or a complete accessory package for this listing. Confirm the supplied modules, platforms and holders before ordering.

Can SI-910 be stacked?

Yes. The manufacturer presents single-, double- and triple-layer arrangements. Have the final stack, support hardware, floor loading, clearances and electrical services reviewed before installation. A stack photograph is not an assembly specification.

Does SI-910 have CO₂, humidity control or HEPA filtration?

No CO₂ or humidity control is specified for SI-910, and HEPA is listed as not offered. Choose SI-960 when the stated CO₂ and humidity capabilities are required; HEPA is optional on that model.

Which electrical version should I specify?

The manufacturer lists single-phase 110 V or 220 V, 50/60 Hz and 1800 W. Confirm the voltage version, plug and site circuit requirements before ordering. Do not assume automatic voltage switching or that one circuit can supply a complete stack.

Does SI-910 provide heat sterilization?

No. SI-910 is listed with a UV germicidal lamp and UV sterilization, not a 90°C moist-heat or 180°C dry-heat cycle. Follow the manufacturer’s operating and cleaning instructions; the UV listing alone does not establish a validated sterilization process.

    SpecificationDetail
    ModelSI-910
    Shaking speed0, 10 to 300 rpm
    Orbit diameter25 mm
    Platform size (L × W)91 × 50 cm
    Platform typeSlide-out
    Platform and inner chamber materialSUS316L stainless steel
    Display10-inch capacitive LCD touchscreen
    ControlPID control; manually editable program
    Timer9999 minutes or 9999 hours
    MotorServo motor
    Speed increment, manufacturer-listed±1 rpm
    Temperature control range4 to 60°C at 23 to 25°C ambient
    Temperature increment, manufacturer-listed±0.1°C
    Temperature uniformity±0.5°C at 37°C
    RefrigerationYes
    Heating power800 W
    Air circulationForced convection with internal circulation
    IlluminationYes
    UV germicidal lampYes
    Door openingGlide-up
    Exterior constructionPowder-coated iron case
    Operating ambient range5 to 40°C
    Power supplySingle-phase, 110 V or 220 V, 50/60 Hz; 1800 W
    CO₂ control rangeNot provided
    Relative humidityNo humidity control specified
    HEPA filtrationNot offered in current specification

    Ordering Information

    Order detailConfiguration
    Catalog numberSI-910
    Product configurationWinpact SI-910 Refrigerated Stackable Incubator Shaker
    Supplied scopeFinal module quantity, voltage, platforms and holders must be specified on the confirmed quotation.
    Packed shipping weightTo be confirmed for the selected order configuration. Instrument masses are not packed shipping weights.

    Configuration and Accessories

    ItemOrdering guidance
    Module arrangementConfirm supplied quantity and approved single-, double- or triple-layer arrangement.
    Flask holders and platformsConfirm current exact-model compatibility and supplied quantities. Do not select from another SI family solely by matching a photo.
    HEPA filtrationOptional on SI-960; not offered in the current SI-910 specification.
    Site servicesConfirm current drawing, support hardware, floor loading, clearances and power for every module.

    Ordering, shipping and product support

    Before ordering: Confirm SI-910, its voltage, supplied module count, labware-retention accessories and site services before ordering. The approved quotation must define delivery, installation, training and any optional equipment.

    Shipping: Blue Tiger Scientific arranges fulfillment through its suppliers. Confirm availability, dispatch timing, packed shipping weight and delivery arrangements before ordering. For heavy or stacked systems, agree freight, unloading, site access and installation responsibilities in advance. Shipping estimates are not guaranteed delivery dates.

    Returns: Start all return requests with Blue Tiger Scientific. Our published policy allows requests within 14 days of delivery unless product-specific terms state otherwise, subject to eligibility and approval. Do not ship anything before receiving an RMA and return instructions. Restocking and shipping charges may apply to approved returns. International returns are not permitted under our published policy.

    Manufacturer support: Contact Blue Tiger Scientific with your order number, model, serial number and a description of the issue for help coordinating support. Applicable manufacturer warranty terms and exclusions govern any warranty claim. We will confirm the process before equipment is sent for evaluation.

    Shipping Policy · Returns & Refunds Policy

    These are manufacturer product literature, not operating or installation manuals. Follow the current instructions supplied with the selected instrument.