Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Luciferase (firefly, recombinant) Proteins Molecular Depot
Luciferase (firefly, recombinant) Proteins Molecular Depot

Luciferase (firefly, recombinant)

$907.00

    Catalog Number: B2017278 (1 ml)

    Luciferase (firefly, recombinant) is firefly luciferase produced by recombinant expression. With D-luciferin, ATP, magnesium and oxygen it emits yellow-green light in proportion to the ATP present. It is used for ATP bioluminescence assays, as a positive control and calibration standard for luciferase reporter gene assays, and for counter-screening luciferase inhibitors. Store at −20°C. Custom bulk amounts of this product are available upon request.

    Products are for in vitro research use only (RUO).

    Live Inquiry about this product via:

    Email: info@bluetigerscientific.com

    Text/SMS: (833) 928-4437 Mon–Fri, (8 am – 8 pm PST)

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

For purchasing details or COA/TDS availability, please request a quote.

Preparing Quote Cart. Your shopping cart stays unchanged.

Luciferase (firefly, recombinant) – Catalog #B2017278

Luciferase (firefly, recombinant) (Catalog #B2017278) is firefly luciferase produced by recombinant expression. With D-luciferin, ATP, magnesium and oxygen it emits yellow-green light. Recombinant enzyme is the form most labs choose for ATP bioluminescence assays and as a positive control or calibration standard for luciferase reporter gene readouts.

Catalog number: B2017278
Lot number: Batch Dependent
Expiration Date: Batch dependent
Amount: 1 ml
Molecular Weight or Concentration: 60 kDa
Supplied as: Powder
Applications: ATP bioluminescence assays, positive control and calibration standard for luciferase reporter gene assays, coupled enzyme assays, screening for luciferase inhibitors
Storage: −20°C
Keywords: Recombinant firefly luciferase, FLuc, luciferase enzyme, ATP assay enzyme, luciferase reporter standard
Grade: Biotechnology grade. All products are highly pure. All solutions are made with Type I ultrapure water (resistivity >18 MΩ-cm) and are filtered through 0.22 um.

Scientific Overview

Firefly luciferase activates D-luciferin with ATP and then oxidizes it with oxygen to produce oxyluciferin and light:

D-Luciferin + ATP + O₂ → Oxyluciferin + AMP + PPi + CO₂ + light (Mg²⁺, luciferase)

The firefly luciferase gene was cloned and expressed in the 1980s, and recombinant enzyme has since replaced insect-derived material for most analytical work. Lundin has reviewed how to set up the luciferase reaction for analytical purposes, including the choice between flash and stable-light conditions. The same enzyme is the reporter in firefly luciferase reporter assays, so purified recombinant luciferase is a natural control and standard for those experiments.

  • ATP detection and ATP-coupled enzyme assays
  • Positive control and standard curve for reporter assays
  • Counter-screening compounds for luciferase inhibition
  • Fusion protein and bioanalytical method development

Usage & Handling Guidance

  • Storage: keep at −20°C. Aliquot on first use to avoid repeated freeze-thaw cycles.
  • Handling: keep on ice while in use. Dilute into buffer that contains a carrier protein such as BSA, since dilute luciferase loses activity on plastic and glass surfaces.
  • Reaction needs: D-luciferin, ATP, magnesium and oxygen, near neutral to slightly alkaline pH.
  • Concentration and activity: not assigned on this listing. Contact us for lot information before ordering and calibrate in your own assay.

Frequently Asked Questions (FAQ)

  • Is luciferin included?
    No. This is the enzyme only. D-luciferin and ATP are purchased separately.
  • Recombinant or native firefly luciferase?
    Both catalyze the same reaction. Recombinant enzyme is free of other firefly proteins, which helps when you need ATP specificity.
  • Can I use it as a standard for my reporter assay?
    Yes, that is a common use. Dilute it in the same lysis buffer as your samples so the standard and samples see the same conditions.
This product is for Research Use Only (RUO). It is not intended for diagnostic or therapeutic use in humans or animals.

References

  • de Wet JR, Wood KV, DeLuca M, Helinski DR, Subramani S. Firefly luciferase gene: structure and expression in mammalian cells. Mol Cell Biol. 1987;7(2):725-737.Reference
  • Lundin A. Optimization of the firefly luciferase reaction for analytical purposes. Adv Biochem Eng Biotechnol. 2014;145:31-62.Reference
  • Lundin A. Use of firefly luciferase in ATP-related assays of biomass, enzymes, and metabolites. Methods Enzymol. 2000;305:346-370.Reference
  • Smirnova DV, Ugarova NN. Firefly luciferase-based fusion proteins and their applications in bioanalysis. Photochem Photobiol. 2017;93(2):436-447.Reference
  • Smale ST. Luciferase assay. Cold Spring Harb Protoc. 2010;2010(5):pdb.prot5421.Reference

    Terms & Conditions

    Blue Tiger Scientific is an independent third-party distributor of select products manufactured by Molecular Depot LLC. By purchasing from bluetigerscientific.com, you (“the Customer”) agree to the following terms, adapted from Molecular Depot’s original conditions:

    Product Use & Eligibility
    Products are for in vitro research use only (RUO). They are not intended for human or animal use, diagnosis, therapy, resale to consumers, or residential delivery. Sales are limited to verified business addresses.

    Payment Terms
    All purchases are prepaid and non-refundable once confirmed. Pricing is in USD and subject to change without notice.

    Purchase Orders
    Confirmed orders are final and may not be canceled or refunded unless authorized in writing.

    Limitation of Liability
    Blue Tiger Scientific and Molecular Depot LLC are not responsible for any damages resulting from product use or misuse.

    Waiver of Claims
    By ordering, you waive all claims arising from use of Molecular Depot products.

    Shipping & Handling
    Shipping is calculated at checkout. A minimum 27% handling fee applies to each order.

    Delivery Estimates All delivery timelines are estimates and not guaranteed. FedEx service levels are subject to operational delays, weather disruptions, and regional restrictions.

    FedEx Pickup Cutoff Orders submitted after the daily FedEx pickup window may not ship until the next available pickup day.

    Shipping Exceptions FedEx may impose restrictions or delays due to package size, weight, destination, or service availability. Blue Tiger Scientific is not liable for delays beyond our control.

    Weekend & Holiday Handling Orders placed on weekends or holidays will be processed on the next business day.

    Returns & Refunds
    Returns must be requested within 30 days through Blue Tiger Scientific. Refunds are only issued for shipping errors or verified defects, and processed within 45 business days if approved. Customers are responsible for return shipping costs unless otherwise stated. Refunds will exclude original shipping fees paid at checkout.

    Warranty Disclaimer
    All products are provided "as-is" with no warranties. Warranty issues are handled by the manufacturer.

    Safety Guidelines
    Always consult the product’s SDS. Products must not be ingested, inhaled, or come into contact with skin or eyes unless specified.

    Legal Use Compliance
    Products must not be used in violation of any law—local, state, federal, or international.

    Accuracy of Orders
    Customers are responsible for verifying all order details before submission.

    Changes or Cancellations
    All changes must be in writing and approved. Cancellations may result in fees for materials, labor, or third-party costs.

    Quality System (MD Levels)
    Molecular Depot’s MD-Quality System includes:

    MD 1000: Non-regulated use, no change notification

    MD 2000: Non-regulated use, limited change notification

    MD 3000: Regulated use, enhanced quality standards

    Delivery & Claims
    Orders may ship in parts. Claims for shortages or defects must be submitted within 2 days of receipt. Delivery dates are estimates only.

    Extended Payment Terms
    Payment is due within 30 days unless agreed otherwise. A 5% weekly penalty applies to late payments. Blue Tiger Scientific reserves discretion on payment application.

    Retention of Title
    Ownership remains with Blue Tiger Scientific or Molecular Depot LLC until payment is complete. Goods must be stored separately and labeled until paid in full.

    Intellectual Property
    No rights to manufacturing processes or IP are transferred. Blue Tiger Scientific is not liable for IP-related claims.

    Force Majeure
    Neither party is liable for delays or failures caused by uncontrollable events (e.g., weather, regulations, supply disruptions).

    Manufacturing Access
    Product purchase does not grant access to proprietary manufacturing documents or methods.

    Resale Prohibition
    Products cannot be resold without written approval from Molecular Depot LLC. Blue Tiger Scientific enforces this restriction.

    Governing Law
    Terms are governed by California and U.S. law. All disputes fall under U.S. jurisdiction.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.