Skip to content
Heathrow Scientific Lab Vortex Mixer with Touch Function Heathrow Scientific
Heathrow Scientific Lab Vortex Mixer with Touch Function Heathrow Scientific
Heathrow Scientific Lab Vortex Mixer with Touch Function Heathrow Scientific
Heathrow Scientific Lab Vortex Mixer with Touch Function Heathrow Scientific
Heathrow Scientific Lab Vortex Mixer with Touch Function U.S Plug (100-120 VAC, 50 60 HZ, 55 W) Heathrow Scientific
Heathrow Scientific Lab Vortex Mixer with Touch Function CE Plug (220-240 VAC, 50 Hz, 44 W) Heathrow Scientific
Heathrow Scientific Lab Vortex Mixer with Touch Function UK Plug (220-240 VAC, 50 HZ, 44 W) Heathrow Scientific
Heathrow Scientific Lab Vortex Mixer with Touch Function Heathrow Scientific
Heathrow Scientific Lab Vortex Mixer with Touch Function Heathrow Scientific
Heathrow Scientific Lab Vortex Mixer with Touch Function Heathrow Scientific
Heathrow Scientific Lab Vortex Mixer with Touch Function Heathrow Scientific
Heathrow Scientific Lab Vortex Mixer with Touch Function U.S Plug (100-120 VAC, 50 60 HZ, 55 W) Heathrow Scientific
Heathrow Scientific Lab Vortex Mixer with Touch Function CE Plug (220-240 VAC, 50 Hz, 44 W) Heathrow Scientific
Heathrow Scientific Lab Vortex Mixer with Touch Function UK Plug (220-240 VAC, 50 HZ, 44 W) Heathrow Scientific

Heathrow Scientific Lab Vortex Mixer with Touch Function

$276.00

    Move between quick touch mixing and supported tube formats without changing the mixing head.

    This Heathrow Scientific lab vortex mixer combines rotary speed control with a multi-format head; choose the electrical model that matches your laboratory.

    • 0–3,000 RPM with a 3.7 mm orbit
    • Positions for microtubes, conical tubes and one assay plate
    • 1 instrument with mixing head, power cord, retention cords and pads

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Order Now
FIND YOUR FIT

Choose your electrical model

Prices apply to the selling unit shown for each configuration. Check the ordering information for package contents.

Available configurations for Heathrow Scientific Lab Vortex Mixer with Touch Function
Product Catalog No. Configuration Selling unit Price Order
120209 BTS-120209 U.S. plug • North American electrical version 1 Each $276.00 per listed selling unit

120212 BTS-120212 CE plug • 220–240 VAC, 50 Hz 1 Each $276.00 per listed selling unit

120214 BTS-120214 UK plug • 220–240 VAC, 50 Hz 1 Each $276.00 per listed selling unit

One head for a changing tube workflow

A morning of sample preparation rarely stays with one tube format. This vortex mixer brings a central touch-mixing pad and several tube-holding positions together on one head, so moving from a hand-held tube to a supported batch does not require a different head attachment. The rotary control lets the operator select the mixing intensity within the instrument’s 0–3,000 RPM range.

Choose the electrical model before the mixing format

The U.S. model, catalog 120209, is for a compatible North American supply. CE model 120212 and UK model 120214 are separate 220–240 V versions. Match the nameplate voltage and frequency to your supply; plug shape alone is not enough.

Hand-held tube on the central mixing pad. Tube and sample are not included.
Hand-held tube on the central mixing pad. Tube and sample are not included.

A multi-format head—not simultaneous capacity in every format

The head provides positions for two 50 mL conical tubes, two 15 mL tubes or two 5 mL tubes using the same retention space, four 1.5/2 mL microtubes, six 0.5 mL microtubes, or twenty-four 0.2 mL strip-tube positions. An assay plate can be retained with the supplied cords. These are format-specific holding arrangements; do not add the numbers together as a combined loading specification.

Make the supported format work for your sample

The center pad suits quick hand-held mixing, while the holding slots and retention cords support the manufacturer’s specified formats. Use approved, securely closed tubes, keep the head attached and load it symmetrically as directed in the manual. Check tube dimensions and closure security rather than treating nominal volume as a guarantee of fit.

The multi-format head supports several separate loading arrangements.
The multi-format head supports several separate loading arrangements.

What belongs on the bench with the instrument

One order includes the vortexer, one power cord, one mixing head, three elastic retention cords and three central mixing pads. The ABS housing and elastomer feet provide a practical benchtop format. Tubes, samples and the assay plate shown in application photographs are not part of the instrument order.

Rotary control or a digital workflow?

Choose this design when a single multi-format head and a straightforward speed dial are the priorities. A digital vortexer is a different purchasing choice when numerical speed and timing controls matter more to the method. Neither format replaces the need to validate the mixing conditions for the actual sample and container.

Buyer FAQs

Which electrical model fits a U.S. laboratory?

Choose the North American model, 120209, for a compatible 50/60 Hz supply. Check the required voltage on the instrument nameplate before connecting it. The CE and UK versions are separate 220–240 V models.

Does every tube format require a separate mixing head?

No. The supplied head incorporates a central touch pad and positions for several tube formats. Use the designated positions and retention arrangement in the manual.

How many 50 mL or 15 mL tubes can it hold?

The head has positions for two 50 mL conical tubes and two 15 mL conical tubes. The two 5 mL positions share the 15 mL retention space. These capacities are not an instruction to load every format simultaneously.

Can I mix an assay plate?

Yes. Secure one compatible assay plate with the retention cords as directed in the manual.

What is supplied with one order?

One vortexer, one power cord, one mixing head, three elastic retention cords and three central mixing pads. Application tubes and samples are not included.

Is this a universal-voltage instrument?

No. The three ordering options are region-specific electrical models. Do not choose a CE or UK model for a North American supply merely by changing the plug.

Can I use open tubes or an unbalanced loading pattern?

Use approved securely closed tubes and load the head symmetrically. The manual warns against open lids, unsecured heads and unbalanced loading; read it before first use.

How does this differ from a digital vortexer?

This model uses a rotary speed dial and one multi-format head. A digital model offers a different control workflow. Choose according to the method’s control and container requirements, not just the maximum speed.

    SpecificationDetail
    BrandHeathrow Scientific
    ProductLab Vortex Mixer with Touch Function
    Speed controlRotary; 0–3,000 RPM
    Orbit3.7 mm
    HousingABS plastic
    Dimensions6.7 × 7.5 × 7.8 in
    Operating temperature2–40°C
    U.S. electrical option120209: North American model, 50/60 Hz, 55 W. Match the voltage on the instrument nameplate to your supply before connecting it.
    CE electrical option120212: 220–240 VAC, 50 Hz, 44 W
    UK electrical option120214: 220–240 VAC, 50 Hz, 44 W
    IncludedVortexer, power cord, mixing head, 3 retention cords, 3 central mixing pads
    Order unit1 Each

    Ordering Information

    Cat. No.DescriptionPack
    120209U.S. plug; North American electrical version1 Each
    120212CE plug; 220–240 V version1 Each
    120214UK plug; 220–240 V version1 Each

    Ordering and support through Blue Tiger Scientific

    Contact Blue Tiger Scientific with the catalog number and order details for availability, ordering assistance or a return request. Obtain authorization and instructions before sending any item back.

    Manufacturer warranty assessment and equipment service are handled under Heathrow Scientific’s applicable product terms. Blue Tiger Scientific coordinates the request and any required manufacturer return authorization; no additional warranty period or direct-sale shipping guarantee is promised here.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Heathrow Scientific Lab Vortex Mixer with Touch Function

Plug Type: U.S Plug (100-120 VAC, 50/60 HZ, 55 W)
Authorized Dealer

One head for a changing tube workflow

A morning of sample preparation rarely stays with one tube format. This vortex mixer brings a central touch-mixing pad and several tube-holding positions together on one head, so moving from a hand-held tube to a supported batch does not require a different head attachment. The rotary control lets the operator select the mixing intensity within the instrument’s 0–3,000 RPM range.

Choose the electrical model before the mixing format

The U.S. model, catalog 120209, is for a compatible North American supply. CE model 120212 and UK model 120214 are separate 220–240 V versions. Match the nameplate voltage and frequency to your supply; plug shape alone is not enough.

Hand-held tube on the central mixing pad. Tube and sample are not included.
Hand-held tube on the central mixing pad. Tube and sample are not included.

A multi-format head—not simultaneous capacity in every format

The head provides positions for two 50 mL conical tubes, two 15 mL tubes or two 5 mL tubes using the same retention space, four 1.5/2 mL microtubes, six 0.5 mL microtubes, or twenty-four 0.2 mL strip-tube positions. An assay plate can be retained with the supplied cords. These are format-specific holding arrangements; do not add the numbers together as a combined loading specification.

Make the supported format work for your sample

The center pad suits quick hand-held mixing, while the holding slots and retention cords support the manufacturer’s specified formats. Use approved, securely closed tubes, keep the head attached and load it symmetrically as directed in the manual. Check tube dimensions and closure security rather than treating nominal volume as a guarantee of fit.

The multi-format head supports several separate loading arrangements.
The multi-format head supports several separate loading arrangements.

What belongs on the bench with the instrument

One order includes the vortexer, one power cord, one mixing head, three elastic retention cords and three central mixing pads. The ABS housing and elastomer feet provide a practical benchtop format. Tubes, samples and the assay plate shown in application photographs are not part of the instrument order.

Rotary control or a digital workflow?

Choose this design when a single multi-format head and a straightforward speed dial are the priorities. A digital vortexer is a different purchasing choice when numerical speed and timing controls matter more to the method. Neither format replaces the need to validate the mixing conditions for the actual sample and container.

Buyer FAQs

Which electrical model fits a U.S. laboratory?

Choose the North American model, 120209, for a compatible 50/60 Hz supply. Check the required voltage on the instrument nameplate before connecting it. The CE and UK versions are separate 220–240 V models.

Does every tube format require a separate mixing head?

No. The supplied head incorporates a central touch pad and positions for several tube formats. Use the designated positions and retention arrangement in the manual.

How many 50 mL or 15 mL tubes can it hold?

The head has positions for two 50 mL conical tubes and two 15 mL conical tubes. The two 5 mL positions share the 15 mL retention space. These capacities are not an instruction to load every format simultaneously.

Can I mix an assay plate?

Yes. Secure one compatible assay plate with the retention cords as directed in the manual.

What is supplied with one order?

One vortexer, one power cord, one mixing head, three elastic retention cords and three central mixing pads. Application tubes and samples are not included.

Is this a universal-voltage instrument?

No. The three ordering options are region-specific electrical models. Do not choose a CE or UK model for a North American supply merely by changing the plug.

Can I use open tubes or an unbalanced loading pattern?

Use approved securely closed tubes and load the head symmetrically. The manual warns against open lids, unsecured heads and unbalanced loading; read it before first use.

How does this differ from a digital vortexer?

This model uses a rotary speed dial and one multi-format head. A digital model offers a different control workflow. Choose according to the method’s control and container requirements, not just the maximum speed.

Use this text to share information about your product.

Use this text to share information about your product.

Use this text to share information about your product.

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.