IKA MultiDrive control MT Milling Package, 100–120 V Default Title Laboratory Mill Package IKA
IKA MultiDrive control MT Milling Package, 100–120 V Laboratory Mill Package IKA
IKA MultiDrive control MT Milling Package, 100–120 V Laboratory Mill Package IKA
IKA MultiDrive control MT Milling Package, 100–120 V Laboratory Mill Package IKA
IKA MultiDrive control MT Milling Package, 100–120 V Laboratory Mill Package IKA
IKA MultiDrive control MT Milling Package, 100–120 V Laboratory Mill Package IKA
IKA MultiDrive control MT Milling Package, 100–120 V Laboratory Mill Package IKA
IKA MultiDrive control MT Milling Package, 100–120 V Default Title Laboratory Mill Package IKA
IKA MultiDrive control MT Milling Package, 100–120 V Laboratory Mill Package IKA
IKA MultiDrive control MT Milling Package, 100–120 V Laboratory Mill Package IKA
IKA MultiDrive control MT Milling Package, 100–120 V Laboratory Mill Package IKA
IKA MultiDrive control MT Milling Package, 100–120 V Laboratory Mill Package IKA
IKA MultiDrive control MT Milling Package, 100–120 V Laboratory Mill Package IKA
IKA MultiDrive control MT Milling Package, 100–120 V Laboratory Mill Package IKA

IKA MultiDrive control MT Milling Package, 100–120 V

$5,578.00

    Weigh and mill suitable dry samples in separate MT tubes. US MultiDrive control MT Package 0010007100 includes the Control drive, TC 1 and five-tube MT 150.5 pack.

    • Five 150 mL MT tubes plus five spare seals; one tube at a time
    • TFT controls and integrated weighing before milling
    • Variable 3,000–20,000 rpm; MT one-minute maximum runs
    • MT cooling and RFID seal-usage limits clearly defined

    Shipping: Provisional 30 lb package allowance, not manufacturer-measured gross. Manufacturer stock, dispatch and final carton details require confirmation. Unsupported destinations are quote-only.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

IKA MULTIDRIVE CONTROL MT PACKAGE • 0010007100 • US 100–120 V

Weigh the sample. Mill in its own tube. Keep the workflow defined.

Bring dry-sample milling and integrated weighing into one benchtop workflow. The IKA MultiDrive control MT Package pairs the TFT-controlled drive with the required TC 1 protective housing and five MT 150 milling tubes, each with a stainless-steel beater and up to 150 mL useful volume.

Choose it for suitable dry, brittle samples when separate sample-contact tubes, visible contents and a defined weighing/milling sequence are useful. The system processes one tube at a time; five supplied tubes do not mean five simultaneous milling positions.

A complete MT-format starting package, not every MultiDrive vessel. US order 0010007100 includes the Control drive, TC 1 and MT 150.5 five-tube pack with five spare seals. Optional MI, BL, BT and DI vessels are separate. Tube operating time, cooling and seal replacement remain essential parts of the method.

Genuine IKA MultiDrive control with TC 1 protective housing and an MT tube mounted
Manufacturer illustration of the Control MT setup. Five tubes are supplied in the MT 150.5 pack; only one is processed at a time. No sample material or additional vessel family is included.
5 × MT 150Separate tubes, not simultaneous positions
150 mLMaximum useful volume per tube
3,000–20,000 rpmVariable speed within vessel/method limits
1 min / 10 minMT maximum run / minimum cooling

Is the Control MT package right for your samples?

For dry, brittle sample preparation

Consider suitable grains, sugar, coffee, tea and tablet samples within the manual’s size, hardness and temperature limits. Final fineness and processing time depend on the sample and method, not merely the maximum speed.

For separate sample-contact tubes

Five transparent plastic tubes support a defined sample workflow. Cleaning or autoclaving does not establish a universal carryover-free or sterile result; validate the method and use a fresh tube where required.

For weighing before processing

Tare and weigh in the same processing vessel while the drive is stopped. The Control’s integrated weighing function can reduce transfers, but its weighing range is not a claim that the MT tube accepts a 4 kg sample.

For short, managed batches

Choose it when one-minute MT runs, cooling intervals and tracked seal wear suit the workload. It is not a continuous-production mill or an unrestricted-use disposable-tube system.

What is included in US package 0010007100?

Closed MT 150 transparent milling tube with stainless-steel beater
One MT 150 shown. MT 150.5 / 0020023173 is a five-tube pack; five spare seals are supplied with the pack, not five extra seals for every tube.

Control drive, protective housing and five-tube pack

  • IKA MultiDrive control drive, US 100–120 V, 50/60 Hz.
  • MultiDrive TC 1 protective housing, catalog 0020023489.
  • MultiDrive MT 150.5, catalog 0020023173: five autoclavable MT 150 tubes with stainless-steel beaters.
  • Five spare seals with the MT pack. The usage-reset procedure requires the corresponding seal code.

The drive manual also lists the power-cord set, USB cable, socket wrench, disassembly tools I and II, cleaning brush, user guide and warranty card. The TC 1 manual lists disassembly tool III with the cover. These support the supplied equipment; they are not extra milling vessel families.

Not included: MI 250-S or other reusable MI chambers, BL or BT blending vessels, DI dispersing vessels, an external cooler, sample material, an analytical balance or a software license. The explicit package scope includes MT 150.5; the manufacturer’s generic “vessels not included” paragraph refers to the other vessel choices.

Check size, hardness and sample chemistry together

The supplied MT tube has its own working envelope

Each MT 150 has a 150 mL maximum useful volume, a standard stainless-steel beater and a maximum stated hardness of 5 Mohs. The general feed-size limit is 10 mm, but the manual requires smaller pieces as hardness increases. At 5 Mohs, the example maximum edge length is 5 mm, not an unconditional 10 mm allowance at maximum hardness.

The intended kit workflow is dry milling. The tube manual marks solvents and abrasive substances as unsuitable. Optional hard-metal accessories elsewhere in the MultiDrive family do not give the supplied MT tube a 9-Mohs rating.

Sample-contact materials include stainless steel, polycarbonate, polyamide, PTFE and silicone. Assess compatibility and possible tool/seal abrasion for the intended analysis. Do not assume suitability for trace-metal-sensitive work or claim contamination-free results.

Dry material should not be loaded above 40°C, and the medium must not exceed 90°C under the manual’s precautions. Processing can add heat quickly. The supplied MT tube does not provide the temperature sensing found in designated optional T vessels.

Opened MT 150 tube and stainless-steel beater from the manufacturer package gallery
Genuine manufacturer detail. The beater is part of the MT tube, not an optional hard-metal or rotor-stator tool. Guard against sharp edges and inspect parts before use.

TFT controls and weighing, without extra sample transfers

Actual MultiDrive control TFT panel detail from the manufacturer image
Actual Control display crop. Example readings are illustrative, not the supplied MT tube’s run-time or seal-life settings.

Weigh at standstill, then choose a suitable milling sequence

The Control provides a TFT display, vessel recognition, RFID usage information and programmable speed/time profiles. Its integrated weighing function lists a 5–4,000 g range and 1 g resolution in current technical data. Weigh only at standstill, tare as instructed and verify performance for the method.

The 4 kg weighing limit is not a working sample-mass rating for a 150 mL plastic tube. An integrated weighing function is also not a substitute for a separately specified analytical balance when the method requires one.

Variable speed spans 3,000–20,000 rpm. The electrical ratings are 1,000 W input and 800 W motor output, not 1,000 W output. Local operation does not require a PC; Micro-USB is available for a separately configured software workflow.

Control supports speed/time programs and adjustable intermittent operation, but the loaded vessel’s shorter timer and cooling limits still apply. Temperature display and monitoring need the correct sensing vessel; those general drive capabilities are not supplied MT sample-temperature measurement.

Three different clocks: run time, cooling and seal usage

A short run limit is not the same as cumulative seal life

One MT processing run: maximum one minute. The drive manual gives a 5-second to 1-minute timer range for MT 150/BT 250. Do not use a generic five-minute package-table rating or another vessel’s 30-minute Control rating as an MT setting.

Cooling between MT runs: at least ten minutes per the current tube technical table. Cooling intervals are not extra processing capacity; stop and allow safe handling before opening or removing the vessel.

MT seal usage: the current tube manual specifies a ten-minute cumulative reference for the MT 150 seal, tracked through the remaining-usage-time display. The BT 250 column is six minutes. These are different tube formats, not interchangeable service-life figures.

When the applicable usage time is exhausted, replace the seal or vessel as instructed. After physically fitting a new seal, enter its supplied six-digit code in the drive’s reset procedure. Resetting the counter alone does not renew a worn part. Inspect the tube, beater and seal regularly; no unlimited number of reuse or autoclave cycles is promised.

MT 150 timing guide: one minute maximum run, ten minutes minimum cooling, ten minutes cumulative seal reference, then physical replacement and coded reset
Original guide based on the current MT/BT manual, revision 032026, and drive manual. Follow the actual vessel recognition, condition and operating instructions.

See the tube-seal maintenance format

IKA’s short BT/MT-family demonstration illustrates the seal-change format. It is not a complete operating procedure or a statement that every bench item shown is supplied. Use the current manual for the actual MT timing, disassembly, seal replacement and code-reset steps.

Official IKA BT/MT tube-seal demonstration, approximately 15 seconds. BT vessels and other laboratory items shown are not additional contents of this MT package.

Cleaning and autoclaving: follow the tube-specific procedure

The current tube manual lists an autoclave condition of 121°C, 2 bar and 20 minutes, with the upper part removed or the vessel completely disassembled. That is a manufacturer procedure reference, not a guarantee of sterility for every load, process or sample.

The MT/BT tube manual permits dishwasher cleaning and describes cleaning with approved water/surfactant or isopropyl alcohol. Those tube instructions do not mean the electrical drive can be autoclaved, immersed or put in a dishwasher. Follow each component’s own instructions and isolate the drive from power before cleaning or accessory work.

Where carryover must be excluded, choose and validate an appropriate fresh-tube workflow rather than treating reused, sterilized plastic as universally contamination-free. Autoclaving does not erase the RFID seal-usage history or replace inspection. Liquid nitrogen is not permitted for direct sample cooling. Any dry-ice method requires the full manual procedure and must never trap evolving gas in a closed tube.

A practical weigh, mill and inspect workflow

Dry-sample workflow: check fit, tare and weigh at standstill, secure tube under TC 1, then mill within the run and cooling limits
Original planning guide. Read the drive and MT/TC 1 manuals before use; this is not a validated sample-preparation or safety protocol.

Define the method before using the maximum speed

  • Confirm sample chemistry, size, hardness, starting temperature and the tube fill limit.
  • Tare and weigh at standstill, then close and mount one tube correctly.
  • Fit the TC 1 protective housing. The interlock is required for MT operation.
  • Choose appropriate speed and a run no longer than one minute; allow at least ten minutes cooling.
  • Inspect the sample and vessel, track cumulative seal usage, and use the specified replacement/reset procedure.

Final fineness depends on material behavior, fill and the actual milling method. Do not infer a guaranteed mesh size, throughput, sample mass or analytical recovery from the maximum motor speed.

Control MT or Basic M20 Successor: choose the sample format

Two different packages, not a simple bigger-or-smaller upgrade

This Control MT package

Choose the supplied five-tube MT format when separate 150 mL sample-contact tubes and Control weighing/TFT functions fit the work. TC 1 is included. Apply MT-specific timing and seal limits.

Basic M20 Successor package

The separate Basic package uses a reusable 250 mL MI 250-S chamber and Basic LED controls. It does not have Control weighing/programming, and MT 150/BT 250 tubes do not operate on the Basic drive, even with TC 1.

Optional Control vessel families

MI milling, BL/BT blending and DI dispersing formats are separately specified options. Their capacities, temperature sensing and operating limits belong to the exact vessel, not automatically to this MT order.

Alternative format: MultiDrive basic M20 Successor package with reusable MI 250-S chamber. Compare the vessel workflow before choosing; MT and MI containers are not supplied together here.

Selection guide: Control MT with five 150 mL tubes and TC 1 versus separate Basic M20 Successor with MI 250-S 250 mL chamber
Original package-selection guide. Optional vessel families are not included in this MT package.

Safety, support and related preparation workflows

Use trained staff, suitable personal protection and process-specific safeguards. Do not bypass the protective housing or vessel interlocks. This mill is not explosion-protected; do not use it for explosive atmospheres or assume every reactive, hazardous, solvent-containing or abrasive material is suitable.

The drive manual states a 24-month baseline manufacturer warranty, excluding wear and faults caused by improper use or inadequate care. Consumable tubes, seals and normal wear are not promised unconditional coverage. Any registration extension depends on IKA’s exact applicable terms. Blue Tiger handles purchases and return requests; IKA handles warranty assessment, technical support, calibration and repairs.

Related workflow: T 25 digital drive for a separately specified liquid-dispersion workflow. It needs its own compatible dispersing tool and support arrangement; neither is part of this MT milling package.

Specify the sample and the tube workflow, not just the drive

For 0010007100, US 100–120 V, tell Blue Tiger the sample material, initial piece size, hardness, intended fill, required result and daily workload. We can coordinate application questions and current manufacturer availability with IKA.

This order includes the MT starting format, not every optional vessel or perpetual consumables supply. The store inventory setting is not a statement of IKA warehouse stock. Dispatch timing and final packed dimensions/mass need order-specific confirmation.

Confirm my sample-preparation setup

Frequently Asked Questions

What does MultiDrive control MT Package 0010007100 include?

The US 100–120 V package includes the MultiDrive control drive, TC 1 protective housing 0020023489 and MT 150.5 pack 0020023173. MT 150.5 supplies five MT 150 milling tubes plus five spare seals. It processes one tube at a time. MI, BL, BT and DI vessel families are not additional supplied items.

Can each supplied MT 150 run for five or thirty minutes continuously?

No. The current drive manual limits MT 150 timer/counter operation to 5 seconds–1 minute, and the tube manual lists a maximum one-minute processing run with at least ten minutes cooling. Generic five-minute package ratings and up-to-thirty-minute Control ratings for other vessels are not MT operating settings.

Is MT 150 seal life six minutes or ten minutes?

The current MT/BT manual’s technical table assigns ten cumulative minutes to the MT 150 seal and six to the BT 250 seal. Follow the recognized vessel’s remaining-usage-time display and current manual. Replace the worn seal or vessel as instructed, then reset using the new seal’s six-digit code; do not reset without replacing the part.

What samples fit the supplied tubes?

The intended workflow is suitable dry samples up to 150 mL useful volume per MT 150, with a standard stainless-steel beater and maximum 5 Mohs hardness. The general 10 mm feed limit becomes smaller as hardness increases; at 5 Mohs the manual example limits edge length to 5 mm. Solvents and abrasive substances are marked unsuitable.

Can I autoclave and reuse MT 150 tubes indefinitely?

No unlimited reuse or cycle count is promised. The tube manual lists 121°C, 2 bar and 20 minutes with the upper part removed or the vessel disassembled. Inspect components, respect seal usage and validate cleaning/carryover requirements. Autoclaving does not reset RFID history or prove every reused tube is contamination-free.

Does the kit measure sample temperature inside MT 150?

No sample-temperature sensing is promised for the supplied MT tube. The Control drive’s general temperature functions require compatible designated sensing vessels. Loading dry material above 40°C or allowing the medium above 90°C conflicts with the tube manual’s precautions; choose the method accordingly.

How does this differ from the Basic M20 Successor package?

This order is the Control drive with TFT, integrated weighing, TC 1 and five 150 mL MT tubes. Basic successor 0010010968 is a separate drive/chamber package with a reusable 250 mL MI 250-S and Basic LED controls. MT/BT tubes do not work on Basic even with TC 1. USB and interval operation are not exclusive Control features.

Do I need another balance, vessel or PC to start?

The supplied MT format includes its required TC 1 and tubes, and local operation does not require a PC. Control weighing lists a 5–4,000 g range and 1 g resolution, but this is not a 4 kg MT sample rating or an analytical-balance guarantee. A different vessel or separate balance may be needed for a different method. Shipping uses a provisional 30 lb packing allowance, not a measured manufacturer gross.

    Product Specifications

    ParameterDetails
    Manufacturer / packageIKA / MultiDrive control MT Package
    US order code0010007100
    Electrical version100–120 V, 50/60 Hz
    Motor input / output1,000 W / 800 W
    Process / supplied formatBatch dry milling in MT 150 tubes
    Speed / deviation3,000–20,000 rpm / ±5% of current speed
    Display / local controlsTFT; vessel recognition, timer and speed/time programming
    Weighing5–4,000 g; 1 g resolution per current technical table; at standstill
    Weighing limit qualificationNot a 4 kg sample rating for the 150 mL tube; verify method suitability
    Supplied tube packMT 150.5 / 0020023173; five tubes plus five spare seals
    Tube useful volume150 mL maximum per MT 150; one tube processed at a time
    Protective housingTC 1 / 0020023489 included and mandatory for MT operation
    MT maximum run / timer1 minute maximum; 5 seconds–1 minute timer/counter per drive manual
    MT minimum cooling10 minutes per current tube technical table
    MT seal-usage reference10 cumulative minutes per current MT manual; RFID usage tracking
    Usage resetFit new seal first, then enter its supplied six-digit code per manual
    MT feed size / hardness10 mm general maximum / 5 Mohs; harder pieces must be smaller
    At 5 MohsManual example: maximum 5 mm edge length, not 10 mm
    Sample-contact materialsStainless steel, PC, PA, PTFE and silicone
    Tube temperature precautionsDry material loaded at no more than 40°C; medium must not exceed 90°C
    Supplied MT temperature sensingNot provided; designated T vessels are separate selections
    Solvents / abrasive substancesNot suitable per current MT/BT manual
    Autoclave reference121°C, 2 bar, 20 minutes; upper part removed or vessel disassembled
    Tube dishwasher cleaningPermitted by MT/BT manual; not a drive-cleaning instruction
    Direct liquid nitrogen coolingNot permitted
    Reusable lifeInspect and follow component/seal condition and usage; no unlimited cycle count promised
    PC interfaceMicro-USB; PC/software not required for local operation
    Drive dimensions W × H × D300 × 350 × 250 mm; not complete installed TC 1 envelope or carton size
    Published component massesDrive 8.5 kg; MT 150 0.110 kg each; not packed shipping gross
    Drive ambient / protection5–40°C, maximum 80% relative humidity / IP31
    Warranty24 months baseline per drive manual, subject to IKA terms and exclusions

    Ordering Information

    ParameterDetails
    Order code / Blue Tiger SKU0010007100 / BTS-0010007100
    Order unitOne US MultiDrive control MT Package
    Main supplied scopeControl drive, TC 1 housing and MT 150.5 five-tube pack
    Consumables suppliedFive MT 150 tubes and five spare seals with the pack
    Separate selectionsOther MI/BL/BT/DI vessels, extra consumables or method-specific equipment
    Shipping planning allowance30 lb provisional package-specific allowance; not manufacturer-measured gross
    DeliveryExisting IKA Parcel Shipping profile; destination limits apply; availability, dispatch and actual carton details confirmed separately

    Authorized reseller

    Blue Tiger Scientific is an authorized reseller of IKA products. We handle your purchase and requests to return an order. IKA is the manufacturer and provides manufacturer warranty coverage, technical service, calibration and repairs. Blue Tiger Scientific does not perform these services or determine warranty coverage.

    Shipping and delivery

    Availability, dispatch timing and freight depend on the product and destination. Delivery dates are estimates unless expressly confirmed as binding in writing by IKA. Contact Blue Tiger Scientific for order-specific shipping information.

    Inspect your delivery

    Inspect the equipment and packaging immediately upon receipt. Report damage, missing items or visible defects to Blue Tiger Scientific immediately, retaining photographs, packaging and shipping documents. IKA's terms require written notice of visible defects, shortages or quality deviations no later than seven days after receipt, and notice of hidden defects no later than seven days after discovery. Prompt reporting allows us to forward the information to IKA within its deadlines. Do not use or install equipment found to be defective until instructions are provided.

    Returns must start with Blue Tiger Scientific

    Contact Blue Tiger Scientific before returning any IKA product. Returns are not automatic and require IKA's written approval and an RMA number. We will provide the approved destination and return instructions; do not ship equipment to Blue Tiger or IKA without those instructions.

    IKA's published return conditions require a written return request within 60 days of shipment, and the returned goods must reach IKA within 30 days after the RMA is issued. These are manufacturer approval requirements, not an unconditional 60-day return guarantee.

    Approved returns must be in excellent, resalable condition in the original container. IKA requires its RMA and original invoice information with the return; Blue Tiger will coordinate the required order documentation. Returns not caused by an IKA error are subject to a minimum 15% restocking charge. Inspection may identify additional service or repair charges needed to restore resalable condition. Return freight is normally prepaid by the purchaser. Charges and any applicable cross-border brokerage responsibility will be confirmed with the authorization. IKA states that returns due to its own error receive full credit. Any customer refund is confirmed through Blue Tiger after the return is accepted and the applicable credit is established. Unauthorized returns may be refused and may receive no credit.

    Manufacturer warranty and service

    IKA handles warranty registration, warranty assessment, technical support, repair and calibration directly. Blue Tiger Scientific does not administer or perform manufacturer warranty service. Keep your proof of purchase and serial number, and register the product with IKA within 90 days of purchase to meet its published registration requirements.

    Warranty periods and free extensions depend on the exact product and IKA's applicable terms. No single warranty period or lifetime-warranty claim applies to all IKA products. IKA determines coverage and the applicable remedy, subject to its conditions and exclusions. For any physical return, including equipment requiring manufacturer service, contact Blue Tiger first so the required authorization and routing are confirmed; IKA handles the technical service itself.

    Cleaning before a service shipment

    Equipment sent to IKA for repair must be cleaned, safely decontaminated as applicable, and accompanied by IKA's completed and signed decontamination certificate. IKA states that it cannot process a repair without this document. Follow the specific authorization and packing instructions before dispatch.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.