Manufacturer front view of IKA LR1000 basic with LED controls; scope follows current US package0020119961
Actual LR1000 basic LED panel detail crop; displayed values are illustrative
Basic LR1000.1 vessel and lid detail from actual manufacturer photograph; same supplied vessel not a second one
Basic lower vessel and base detail; internal cooling coils are not exposed
Original Basic formulation planning guide, not installation or safety instructions
Original Basic versus Control and separate-equipment guide; Control and optional equipment not included
Manufacturer front view of IKA LR1000 basic with LED controls; scope follows current US package0020119961
Actual LR1000 basic LED panel detail crop; displayed values are illustrative
Basic LR1000.1 vessel and lid detail from actual manufacturer photograph; same supplied vessel not a second one
Basic lower vessel and base detail; internal cooling coils are not exposed
Original Basic formulation planning guide, not installation or safety instructions
Original Basic versus Control and separate-equipment guide; Control and optional equipment not included

IKA LR 1000 basic 1 L Laboratory Reactor System, US 100–115 V

$10,018.00

    A defined 1 L formulation platform, with straightforward LED operation. IKA 0020119961 supplies the US Basic base, LR 1000.1 vessel, LR 1000.11 anchor and PT 100.30 sensing hardware.

    • 300–1,000 mL useful range without a disperser
    • Variable 10–150 rpm anchor stirring; up to 100,000 mPa·s published viscosity rating
    • 120°C maximum medium temperature with immersed-sensor control
    • US 100–115 V; Basic LED, not Control weighing, pH or torque-trend features

    Shipping: US checkout coverage uses a provisional 65 lb packed-weight allowance, not manufacturer-measured gross. Regional freight, US territory, international and special-service exceptions require a quote as applicable. Automated arrival dates are estimates until confirmed.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

IKA LR 1000 BASIC SYSTEM • 0020119961 • US 100–115 V

A defined 1 L mixing-and-heating platform. Straightforward LED operation.

Give suitable formulation trials a specified vessel, anchor stirrer and immersed temperature sensor instead of treating every run as an improvised beaker setup. The IKA LR 1000 basic System brings bottom heating and 10–150 rpm anchor mixing together for laboratory-scale chemical processes and suitable creams, lotions and other viscous formulations.

US catalog 0020119961 includes the Basic base, LR 1000.1 vessel, LR 1000.11 anchor stirrer, PT 100.30 temperature sensor and LR 1000.61 sensor receptacle. Its seven-segment LED interface keeps the core operating values in view.

Choose Basic when those core functions meet your method. If onboard weighing, a pH-electrode connection or relative torque-trend display is a requirement, compare Control before you order. Basic does not acquire those hardware functions simply by adding software.

Manufacturer front view of the IKA LR 1000 basic System with LED controls
Current manufacturer illustration for Basic. Readings are illustrative; the current US supplied-parts checklist defines the order, not every detail in a family photograph.
1 LMaximum useful volume
10–150 rpmVariable anchor-stirring speed
120°CMaximum working temperature of the medium
LED controlsBasic operation, not the Control TFT interface

A QUICK BUYING DECISION

Is Basic the right system for your lab?

A fit for suitable viscous formulation R&D

Consider this platform when your work needs anchor mixing and controlled heating in the 300–1,000 mL range without a dispersing tool. Suitable cosmetic and pharmaceutical development work can include cream or lotion trials, provided the material, method and safety limits fit.

Choose core functions without unused instrumentation

Basic makes sense when LED operation, temperature control with the supplied sensor and timed stirring are the functions you need. It does not include Control’s weighing, pH connection or relative torque-trend display.

Know which core parts arrive together

The factory order specifies the Basic base, LR 1000.1 vessel, LR 1000.11 anchor and PT 100.30 sensing hardware. You can separate the core system from an optional disperser, cooling source or vacuum arrangement before planning the full method.

Keep a clear upgrade decision

Compare the linked Control system when its added measurement and interface functions have a purpose in your process. Both versions share the published 1 L capacity and 120°C medium limit, but their supplied vessels, anchors and seal details are not identical.

Choose another platform when the limits do not fit.

This is not a micro-volume, greater-than-1 L, positive-pressure or above-120°C sample-temperature configuration. With a suitable optional disperser, the useful-volume minimum is 500 mL. A viscometer is a separate instrument: Basic does not measure absolute viscosity.

What is included in US system 0020119961?

Genuine detail of the Basic reactor vessel and lid from IKA’s manufacturer photograph
The supplied vessel is LR 1000.1. Do not substitute Control’s LR 1000.3 or infer an included disperser from a port or illustration.

A manufacturer-defined system, not a collection of assumed extras

  • LR 1000 basic base in the specified US 100–115 V, 50/60 Hz version.
  • LR 1000.1 laboratory reactor vessel.
  • LR 1000.11 anchor stirrer.
  • PT 100.30 temperature sensor and LR 1000.61 sensor receptacle.
  • Support rod for securing approved accessories.
  • Two hose connectors for cooling connections.
  • The Basic operating-manual scope also identifies the mains cable, tool kit, instructions and warranty card.

Not listed as included: an external chiller or other cooling supply, vacuum pump, T 25 disperser, reactor-specific dispersing element and fitting, reflux condenser or labworldsoft software license. A USB cable is listed in the manual’s Control delivery column, not the Basic column; it is not promised with this Basic order.

The Basic order lists LR 1000.11, not Control’s LR 1000.10 anchor with PEEK scrapers. Select from the actual US scope rather than importing the Control package’s scraper or FFKM-vessel claims.

Set the method around the batch, not only the dial

Use the specified volume window

The useful-volume range is 300–1,000 mL without a dispersing tool and 500–1,000 mL with an appropriate tool. These are configuration limits, not permission to run an arbitrary charge, leave the sensor uncovered or fill every formulation to the maximum.

Match the material to anchor mixing

The maximum published viscosity is 100,000 mPa·s. Batch composition, temperature, loading and the installed tool still affect performance. The rating is not a measured viscosity output, a guarantee at every speed or a promise of a particular emulsion result.

Check the actual wetted assembly

The manual identifies stainless steel including 316L/316Ti, borosilicate glass 3.3 and PTFE in the assembly, with FKM O-rings for LR 1000.1. Check compatibility against the actual supplied components, reagents and conditions; no blanket chemical compatibility is claimed.

LED operation with the values that matter for Basic

Actual LR 1000 basic seven-segment LED control panel detail
Genuine crop of the Basic photograph, not a fabricated display. Values shown are illustrative, not recommended settings for a formulation.

Set speed, follow temperature and time the operation

The seven-segment LED interface displays the core operating values and uses rotary controls for adjustment. Stirring speed is adjustable from 10 to 150 rpm in 1 rpm increments, with a published ±5 rpm deviation. The timer helps define a repeatable run sequence.

An external PT 100.30 sensor is supplied for measuring the medium. Basic supports temperature setting in 1 K increments and a stated 0.1 K temperature-measurement resolution. Those two figures describe different functions.

Basic is not Control. It has no integrated weighing function, pH-electrode interface, relative torque-trend display or MV1 valve-control interface. Use separate appropriate instruments when the method needs those measurements, or choose the Control system for its documented functions.

USB and RS 232 interfaces support a separately configured PC workflow under the manufacturer’s instructions. Optional software does not turn Basic into Control, and a labworldsoft license is not listed as part of this system.

Control the medium temperature, not an assumed hotplate temperature

The medium limit is 120°C, not 180°C

The integrated heating block transfers heat through the vessel bottom. Control against the supplied sensor’s medium measurement so the process is based on the sample temperature, not only the heater setting.

Maximum working temperature of the medium: 120°C. IKA’s separate 180°C heating-temperature figure refers to the heating block and does not authorize operating the formulation at 180°C.

Keep the external temperature sensor immersed at least 20 mm, as the operating manual requires. Select a suitable safety-circuit setting for the medium and the method, account for residual heat and keep the vessel and lid correctly secured.

The system switches off heating and stirring when the vessel or lid is removed during operation. Replace and lock the components and follow the specified restart procedure; a safety cutout is not a substitute for trained supervision.

Detail of the Basic vessel seated on the heated base
Manufacturer-photo detail of the base and lower vessel. The internal heating block and cooling coils are not exposed in this photograph.

Cooling is a separate utility choice

LR 1000 basic provides flow-through cooling through coils in the base. An external cooling source is not included. Choose an appropriate arrangement for the desired heat-removal duty, sample and timing rather than treating the reactor as a refrigerated instrument.

Respect both the data limit and the setup instruction

The manufacturer states a 3°C minimum cooling-medium temperature and 1 bar maximum permissible cooling-medium pressure. The operating manual also requires an unpressurized cooling arrangement. Do not interpret the limit as approval for an unrestricted pressurized supply.

Connect for cooling, not external heating

Secure the inlet/outlet hoses, provide the specified return or drain arrangement and follow the manufacturer’s connection procedure. The connections are for cooling only, not a general-purpose external heating jacket.

Do not add Control-only valve functions by assumption

The Basic model does not provide Control’s MV1 valve interface. Plan any separate cooling equipment and control arrangement against the actual Basic configuration; a valve and automated cooling package are not supplied here.

A practical Basic formulation workflow

Original Basic workflow guide: select a suitable batch, anchor mix, follow medium temperature, cool and document
Original planning guide. If adding a compatible disperser, use the separate 500–1,000 mL range. Follow the full installation and safety instructions.

Give each trial a defined starting point

  • Choose suitable media, batch volume and mixing conditions, including the actual seal and material compatibility.
  • Inspect and correctly install the vessel, lid, anchor and PT 100 sensor. Keep the medium within the applicable fill range and the probe immersed.
  • Start at a suitable low speed and adjust within the 10–150 rpm range; control heating against measured medium temperature.
  • Use the separately selected cooling arrangement when required and document the operating conditions and observations.
  • Stop, allow safe handling temperatures and isolate the electrical supply before changes or cleaning, as the manual directs.

Basic does not tell you that an emulsion has reached a validated endpoint. Use appropriate separate measurements and your own method criteria instead of assuming a timed run or maximum speed proves product quality.

Basic or Control: choose the functions, then verify the hardware

Original LR 1000 Basic versus Control selection guide and separate-equipment reminder
This order is Basic with LR 1000.1 and LR 1000.11. Control and external instruments are separate products, not extra equipment included here.

Choose this Basic system for its core workflow

A defined 1 L anchor-stirring and heating platform, LED operation and PT 100.30 sensing. Choose it when these functions and the actual Basic materials and ports suit the method.

Choose Control when the added instrumentation matters

Control provides the TFT interface, weighing, pH-electrode connection and relative torque-trend function. Its LR 1000.3 vessel and documented supplied hardware also differ; do not treat the two packages as identical except for the screen.

Neither system includes every external instrument

Cooling, vacuum and high-shear dispersion require separately selected equipment. A pH connection is not an included electrode, and a compatible T 25 drive still needs the correct reactor tool and fitting.

Vacuum use is not pressure-reaction service

The specified attainable vacuum is 25 mbar with an appropriate separately selected vacuum arrangement. No vacuum pump is listed in this Basic system’s current US scope. Follow the actual supplied vessel and lid configuration; a port or a drawing is not proof that every vacuum accessory is supplied.

The LR 1000 is not designed for overpressure. At normal pressure, keep the reactor appropriately ventilated to prevent pressure buildup. Volatile processes can require a suitable lid-mounted condenser and laboratory ventilation selected for the application.

The cooling-circuit pressure limit is not a reaction-vessel pressure rating. Do not operate in an explosive atmosphere, bypass the vessel/lid protections or process media that can react dangerously to energy input. Use only trained staff and appropriate process-specific safeguards.

Clean the components for the next trial

Separate the vessel-cleaning task from the electrical base

Stop operation, allow safe handling temperatures and disconnect mains before cleaning. The manual identifies product-contacting components as suitable for laboratory dishwashers, but electrical equipment and handles must not be immersed.

Use the specified cleaning-agent limits

The manual identifies water containing surfactant and isopropyl alcohol as approved cleaning agents. Follow its cleaning/disinfection pH 5–8 restriction and exclusions for corrosive agents. Cleaning permission is not blanket approval to process the same chemical in a reaction.

Inspect the glass, seals and stirrer

Check for damaged glass, residue, seal degradation and wear before the next run. Basic’s LR 1000.1 O-ring material is FKM; do not assume Control’s FFKM seal claim. Consult IKA before unlisted cleaning or decontamination methods.

Start product return requests through Blue Tiger Scientific. IKA handles manufacturer technical support, warranty assessment, calibration where applicable and repairs under its terms. The operating manual states a 24-month warranty subject to conditions and exclusions including wear, improper use and insufficient care.

Select the next step in your workflow

Alternative model: LR 1000 control System, US 115 V for the documented TFT, weighing, pH-connection and torque-trend functions. Compare actual vessel, anchor and seal details before choosing; Control is not a larger-capacity version.

Compatible accessory: T 25 digital drive for a separately configured reactor-dispersion setup. IKA’s reactor manual identifies S 25 KV-25 F/G tools; select the correct tool and fitting together. The drive-only page does not supply those automatically, and S 25 N-18 G is not established here as the reactor tool.

Related workflow: RV 10 digital pro V-C Complete for separate rotary evaporation. It is a different solvent-removal/concentration system, not a pump or other accessory included with this reactor.

Ready to specify the Basic system?

Ordering the standard US setup: choose catalog 0020119961 when the LR 1000.1 vessel, LR 1000.11 anchor and supplied temperature-sensing hardware match the method. Review the included-parts checklist and the delivery options shown with your order.

Need options or procurement confirmation? Tell Blue Tiger the target batch, material and whether you need dispersion, cooling or vacuum. Ask us to confirm order scope, request current manufacturer availability and dispatch information, and coordinate manufacturer application questions before a time-critical purchase.

Ask about options or availability

Mention LR 1000 basic and catalog 0020119961. Manufacturer stock and dispatch are confirmed separately. The checkout weight allowance is provisional; automated arrival dates are not a confirmed supplier lead time.

Frequently Asked Questions

Is LR 1000 basic suitable for cream or lotion formulation trials?

IKA describes the system for laboratory mixing and chemical-process development, particularly in cosmetic and pharmaceutical applications. For a suitable cream, lotion or other viscous formulation, check the actual medium, seals, temperature, useful-volume range and mixing needs. A 100,000 mPa·s rating is not a guarantee of a particular emulsion quality or permission for every ingredient.

What is included with US IKA system 0020119961?

The current US scope lists the Basic base, LR 1000.1 vessel, LR 1000.11 anchor stirrer, PT 100.30 sensor, LR 1000.61 receptacle, support rod and two hose connectors. The Basic manual also identifies the mains cable, tool kit and documentation. External cooling, a vacuum pump, T 25/reactor tool/fitting, condenser and labworldsoft license are not listed as supplied.

What do I give up by choosing Basic rather than Control?

Basic uses LED operation and does not provide Control’s TFT interface, weighing function, pH-electrode connection, relative torque-trend display or MV1 valve-control interface. Both versions share a 1 L maximum useful volume, 10–150 rpm speed range and 120°C medium limit in the manual. The vessel, anchor and seal scope differ; software does not add the missing Control hardware functions.

What is the minimum batch size, with or without a disperser?

The manufacturer specifies 300–1,000 mL without a dispersing tool and 500–1,000 mL with an appropriate optional tool. Keep the supplied temperature sensor immersed at least 20 mm and follow the configuration’s other limits. Do not assume the 1 L system supports arbitrary micro-volume batches or that 1 L is always the recommended charge.

Does the 180°C heater specification allow 180°C formulations?

No. The maximum working temperature of the medium is 120°C. The separate 180°C heating-temperature figure refers to the heating block, not the allowed sample temperature. Use the immersed sensor, suitable safety-circuit setting, compatible materials and the complete operating instructions.

Is a chiller included, and how is cooling connected?

A chiller is not included. Cooling uses coils in the base and an appropriately selected external source. The published coolant limits are a 3°C minimum temperature and 1 bar maximum permissible pressure; the manual also requires an unpressurized cooling arrangement. Secure hoses and follow the inlet/outlet instructions. Basic does not include Control’s MV1 valve interface.

Can the Basic reactor be used under vacuum or positive pressure?

The specified attainable vacuum is 25 mbar with a suitable separately selected arrangement. A vacuum pump is not in the Basic scope. The system is not designed for overpressure, and normal-pressure operation requires appropriate ventilation to prevent buildup. Do not confuse the cooling-circuit pressure limit with a reaction-vessel pressure rating.

Can I use a T 25 digital drive and the S 25 N-18 G tool with this reactor?

IKA names T 25 digital as an accessory, but the reactor manual identifies S 25 KV-25 F and S 25 KV-25 G dispersing elements. Select the appropriate drive, reactor-specific tool and fitting together; do not assume the S 25 N-18 G used for other T 25 tasks fits this reactor. With dispersion, use the separate 500–1,000 mL volume range.

    Product Specifications

    ParameterDetails
    Manufacturer / modelIKA / LR 1000 basic System
    US catalog0020119961
    Voltage / frequency100–115 V / 50–60 Hz, per current US technical data
    Power input / heat output1,200 W / 1,000 W
    Useful volume, no disperser300–1,000 mL
    Useful volume, with suitable disperser500–1,000 mL; optional drive, tool and fitting required
    Maximum published viscosity100,000 mPa·s; not a viscosity measurement
    Stirring speed10–150 rpm
    Speed adjustment / deviation1 rpm increments / ±5 rpm
    Supplied vesselLR 1000.1
    Supplied anchorLR 1000.11; do not import Control LR 1000.10 scraper claims
    Vessel O-ring materialFKM for LR 1000.1, per operating manual
    Documented wetted assemblyStainless steel including 316L/316Ti, borosilicate glass 3.3 and PTFE; verify actual supplied components for the medium
    Lid openings1 × NS 29/32 and 3 × NS 14/23, per current Basic technical data
    Temperature sensor / receptaclePT 100.30 / LR 1000.61 supplied
    Maximum medium working temperature120°C
    Heating-block specification180°C maximum; not the medium temperature limit
    Temperature setting / measurement resolution1 K setting increments / 0.1 K measurement resolution
    Control with external sensor±0.2 K per manufacturer data
    Sensor immersionAt least 20 mm in the medium, per manual
    Adjustable safety circuit47–225°C with the manual’s specified endpoint tolerances
    Display / heat controlsSeven-segment LED / LED
    TimerProvided
    Weighing / pH interfaceNot provided on Basic
    Torque-trend / MV1 interfaceNot provided on Basic
    CommunicationUSB Micro-B and RS 232
    Software / USB cableSoftware license not listed as supplied; USB cable not promised in Basic manual scope
    CoolingFlow through base coils; external source selected separately
    Cooling-medium limitsMinimum 3°C; maximum permissible pressure 1 bar; manual also requires an unpressurized setup
    Vacuum capability25 mbar attainable with an appropriate separately selected arrangement
    Overpressure useNot designed for positive-pressure reaction service
    Support rod16 mm diameter
    Permissible operating time100% per technical data, within process and medium limits
    Device dimensions W × H × D443 × 360 × 295 mm; not carton dimensions
    Published system weight22 kg in current US product data; not confirmed packed shipping gross
    Ambient / protection+5 to +40°C / IP21
    Maximum ambient relative humidity80%

    Ordering Information

    ParameterDetails
    Catalog number / Blue Tiger SKU0020119961 / BTS-0020119961
    Order unit1 manufacturer-defined US Basic reactor system
    Core equipmentBasic base, LR 1000.1 vessel, LR 1000.11 anchor and supplied sensing hardware
    Separate optionsT 25 setup, external cooling, vacuum pump, condenser and PC software as required; not included by assumption
    Checkout shipping-weight basis65 lb provisional packed-weight allowance, not manufacturer-measured gross
    Weight interpretationCurrent US system data lists 22 kg; do not treat published device/system mass as packed weight
    DeliveryEligible US rates apply after publication. Remote freight, territory and international exceptions require a quote; timing is confirmed separately.

    Authorized reseller

    Blue Tiger Scientific is an authorized reseller of IKA products. We handle your purchase and requests to return an order. IKA is the manufacturer and provides manufacturer warranty coverage, technical service, calibration and repairs. Blue Tiger Scientific does not perform these services or determine warranty coverage.

    Shipping and delivery

    Availability, dispatch timing and freight depend on the product and destination. Delivery dates are estimates unless expressly confirmed as binding in writing by IKA. Contact Blue Tiger Scientific for order-specific shipping information.

    Inspect your delivery

    Inspect the equipment and packaging immediately upon receipt. Report damage, missing items or visible defects to Blue Tiger Scientific immediately, retaining photographs, packaging and shipping documents. IKA's terms require written notice of visible defects, shortages or quality deviations no later than seven days after receipt, and notice of hidden defects no later than seven days after discovery. Prompt reporting allows us to forward the information to IKA within its deadlines. Do not use or install equipment found to be defective until instructions are provided.

    Returns must start with Blue Tiger Scientific

    Contact Blue Tiger Scientific before returning any IKA product. Returns are not automatic and require IKA's written approval and an RMA number. We will provide the approved destination and return instructions; do not ship equipment to Blue Tiger or IKA without those instructions.

    IKA's published return conditions require a written return request within 60 days of shipment, and the returned goods must reach IKA within 30 days after the RMA is issued. These are manufacturer approval requirements, not an unconditional 60-day return guarantee.

    Approved returns must be in excellent, resalable condition in the original container. IKA requires its RMA and original invoice information with the return; Blue Tiger will coordinate the required order documentation. Returns not caused by an IKA error are subject to a minimum 15% restocking charge. Inspection may identify additional service or repair charges needed to restore resalable condition. Return freight is normally prepaid by the purchaser. Charges and any applicable cross-border brokerage responsibility will be confirmed with the authorization. IKA states that returns due to its own error receive full credit. Any customer refund is confirmed through Blue Tiger after the return is accepted and the applicable credit is established. Unauthorized returns may be refused and may receive no credit.

    Manufacturer warranty and service

    IKA handles warranty registration, warranty assessment, technical support, repair and calibration directly. Blue Tiger Scientific does not administer or perform manufacturer warranty service. Keep your proof of purchase and serial number, and register the product with IKA within 90 days of purchase to meet its published registration requirements.

    Warranty periods and free extensions depend on the exact product and IKA's applicable terms. No single warranty period or lifetime-warranty claim applies to all IKA products. IKA determines coverage and the applicable remedy, subject to its conditions and exclusions. For any physical return, including equipment requiring manufacturer service, contact Blue Tiger first so the required authorization and routing are confirmed; IKA handles the technical service itself.

    Cleaning before a service shipment

    Equipment sent to IKA for repair must be cleaned, safely decontaminated as applicable, and accompanied by IKA's completed and signed decontamination certificate. IKA states that it cannot process a repair without this document. Follow the specific authorization and packing instructions before dispatch.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.