Skip to content
Hanna Instruments HI6321-01 Advanced Conductivity Benchtop Meter Benchtop Conductivity Meter Hanna Instruments
Hanna Instruments HI6321-01 Advanced Conductivity Benchtop Meter Benchtop Conductivity Meter Hanna Instruments
Hanna Instruments HI6321-01 Advanced Conductivity Benchtop Meter Benchtop Conductivity Meter Hanna Instruments
Hanna Instruments HI6321-01 Advanced Conductivity Benchtop Meter Benchtop Conductivity Meter Hanna Instruments
Hanna Instruments HI6321-01 Advanced Conductivity Benchtop Meter Benchtop Conductivity Meter Hanna Instruments
Hanna Instruments HI6321-01 Advanced Conductivity Benchtop Meter Benchtop Conductivity Meter Hanna Instruments

Hanna Instruments HI6321-01 Advanced Conductivity Benchtop Meter

$1,124.99

    Elevate your water quality analysis with the Hanna HI6321 Advanced Conductivity Benchtop Meter, offering precise measurements for EC, Resistivity, TDS, Salinity, and Temperature on an intuitive large touchscreen. Engineered for industrial process water and high-purity applications, it ensures stable results across a wide range with minimal calibration needs.

    • Intuitive touchscreen display for effortless operation.

    • Versatile measurement of EC, TDS, Salinity, and Resistivity.

    • Advanced temperature compensation algorithms for diverse water types.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b
Hanna HI6321 Front View

User Interface

  • 7-inch capacitive touch screen with multi-touch support for effortless navigation.
  • Intuitive capacitive touch back, home, and system menu keys for streamlined operation.
  • User-friendly icons and symbols provide clear, quick interpretation of instrument functions.

Five Intuitive Views

  • Basic measurement configuration for quick startups.
  • Simple GLP (Good Laboratory Practice) view with essential calibration information.
  • Full GLP details including electrode status and comprehensive calibration point data.
  • Live, interactive graphical display for real-time data visualization.
  • Tabulated data view with date, time, and customizable notes for detailed record-keeping.

Measurement Versatility

  • Measure a comprehensive suite of parameters including µS/cm, mS/cm (Conductivity), Ω·cm, kΩ·cm, MΩ·cm (Resistivity), ppm, ppt (TDS), and ppt, PSU, % (Salinity), all with integrated temperature measurement.
  • Utilize application-specific profiles for direct, efficient measurements without needing to adjust sensor or system settings.
  • Benefit from an active log during measurement for continuous data recording.
  • Ensure reliable results with a clear measurement stability indicator based on user-defined criteria.
  • Choose from direct and direct/autohold reading modes for flexible data capture.
  • Configure temperature compensation to be automatic or set manually for precise adjustments.
  • Receive audible and/or alarm messages when measurements fall outside of predefined limits, ensuring immediate action.
  • Experience enhanced accuracy and stability with galvanic isolation for conductivity measurement.

Advanced Calibration

  • Perform standard single-point salinity calibration using 100% salinity standard, with the reading salinity scale set to percentage.
  • Conduct standard single or multiple conductivity calibrations with a wide range of available standards.
  • Rest assured with non-volatile memory that securely saves all your valuable data and instrument settings.
Hanna HI6321 Left View
Hanna HI6321 Rear Angle View

Extensive Data Logging

  • Collect and store an impressive 1,000,000 data points with precise time and date stamps.
  • Choose from flexible logging types including manual, automatic, and autohold to suit your workflow.
  • Easily identify and track samples with dedicated Sample IDs for manual and autohold data entries.

Robust Connectivity & Services

  • Effortlessly transfer logged data directly to a USB thumb drive for convenient external storage.
  • Export log files, including measurements and calibration data, as standard .csv files for easy analysis.
  • Utilize FTP and email for seamless log export via both Ethernet and Wi-Fi connections.
  • Connect USB Type A devices such as USB sticks, keyboards, and printers for expanded functionality.
  • Use the USB Type C port for additional USB stick connectivity and direct PC connection.

Integrated Help Section

  • Access comprehensive video support presentations directly on the meter for guidance on main functionalities.
    Specification Detail
    SKU HI6321-01
    EC Range 0.000 to 9.999 μS/cm, 10.00 to 99.99 μS/cm, 100.0 to 999.9 μS/cm, 1.000 to 9.999 mS/cm, 10.00 to 99.99 mS/cm, 100.0 to 1000.0 mS/cm
    EC Resolution 0.001 μS/cm, 0.01 μS/cm, 0.1 μS/cm, 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm
    EC Accuracy ±1 % of reading (±0.01 μS/cm)
    EC Calibration automatic standard recognition (84.00 µS/cm, 1.413 mS/cm, 5.000 mS/cm, 12.88 mS/cm, 80.00 mS/cm, 111.8 mS/cm) or user standard single point or multi-point calibration
    TDS Range 0.000 to 9.999 ppm, 10.00 to 99.99 ppm, 100.0 to 999.9 ppm, 1.000 to 9.999 ppt, 10.00 to 99.99 ppt, 100.0 to 400.0 ppt actual TDS (with 1.00 factor)
    TDS Resolution 0.001 ppm, 0.01 ppm, 0.1 ppm, 0.001 ppt, 0.01 ppt, 0.1 ppt
    TDS Accuracy ±1 % of reading (±0.01 ppm)
    Resistivity Range 1.0 to 99.9 Ω·cm, 100 to 999 Ω·cm, 1.00 to 9.99 KΩ·cm, 10.0 to 99.9 KΩ·cm, 100 to 999 KΩ·cm, 1.00 to 9.99 MΩ·cm, 10.0 to 100.0 MΩ·cm
    Resistivity Resolution 0.1 Ω·cm, 1 Ω·cm, 0.01 KΩ·cm, 0.1 KΩ·cm, 1 KΩ·cm, 0.01 MΩ·cm, 0.1 MΩ·cm
    Resistivity Accuracy ±1 % of reading (±1 Ω·cm)
    Salinity Range 0.00 to 42.00 PSU - Practical Scale, 0.00 to 80.00 ppt - Natural Sea Water, 0.0 to 400.0 % - Percent Scale
    Salinity Resolution 0.01 for Practical Scale / Natural Sea Water, 0.1 % for Percent Scale
    Salinity Accuracy ±1 % of reading
    Salinity Calibration 1 point for Percent Scale
    Temperature Range −20.0 to 120.0 °C, −4.0 to 248.0 °F, 253.0 to 393.0 K
    Temperature Resolution 0.1 °C, 0.1 °F, 0.1 K
    Temperature Accuracy ±0.2 °C, ±0.4 °F, ±0.2 K
    EC/TDS Probe HI7631233 four-ring conductivity/ resistivity/TDS/salinity probe
    Power Supply DC adapter 100-240AC to 24VDC 2.5A
    Environment 0 - 50 °C / 32 - 122 °F / 273 - 323 K maximum 95% RH non-condensing
    Dimensions 205 x 160 x 77 mm (8.0 x 6.2 x 3.0 in)
    Weight Approximately 1.2 kg (2.65 lbs.)
    Ordering Information HI6321 is supplied with HI7631233 probe, HI764060 electrode holder, capillary pipette, 24 VDC power adapter, USB-C to USB-A cable, probe quality certificate, quick reference guide with instrument quality certificate.
    Warranty 2 years

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.
    HI6321 Advanced Conductivity Benchtop Meter Instruction Manual
    Download
    HI6321 Conductivity Meter Manual

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)