Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Hanna HI96794-25 Chloride High Range Reagent Kit — 25 Vials Default Title Photometer Reagents Hanna Instruments
Hanna HI96794-25 Chloride High Range Reagent Kit — 25 Vials Default Title Photometer Reagents Hanna Instruments

Hanna HI96794-25 Chloride High Range Reagent Kit — 25 Vials

$137.49

    Chloride results without heated digestion. Select the matched HR kit for chloride ion—not chlorine or salinity.

    • 80–1000 mg/L as Cl⁻; HI83314 / HI83399 methods
    • 25 vials; up to 24 sample tests after one separate blank
    • 0.1 mL sample; 3-minute color development

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

Know your chloride level—not just your salt level.

Measure chloride ion in water without a heated digestion step. This matched high-range reagent kit supports 80–1000 mg/L as Cl⁻ on the documented HI83314 and HI83399 methods, helping you choose chloride chemistry rather than a chlorine or salinity test.

Hanna HI96794-25 high-range chloride kit with HI96794V-0 vials and HI96793-0 reagent bottle
Factory photograph identifies the HR kit and its shared-code liquid component. Packaging, lot and expiry shown are illustrative.

Choose the right analyte and range

Choose this kit for chloride ion (Cl⁻), not free or total chlorine (Cl₂), and not sodium-chloride salinity. The documented range is 80–1000 mg/L as Cl⁻. For expected levels below 100 mg/L, the manuals recommend the lower-range method for improved precision; this page sells only the HR kit.

A short, nonheated workflow

Add 0.1 mL of sample to the sample vial. Slowly add 3 mL of HI96793-0 Chloride Reagent to each sample vial and to the separate blank vial, following the manual’s mixing instructions. Allow 3 minutes for color development, zero with the blank, then read the sample. No external heated digestion or reactor is specified.

What is included—and the real sample capacity

Supplied as the HI96794-25 high-range kit: 25 HI96794V-0 reagent vials and HI96793-0 Chloride Reagent bottle. HI96793-0 is the legitimate liquid component of this HR kit, not an alias for the HI96793-25 low-range kit. Total bottle fill volume is not stated here; the 3 mL dose is not a bottle-volume specification. One pack contains 25 reagent vials. The current instrument manuals specify reagents for 24 sample tests: a separate reagent blank consumes one vial. Up to 24 sample tests assumes one blank reused within the permitted window; fresh blanks, quality-control checks and repeats consume additional capacity. This is not a promise of 25 independent sample tests.

Plan batches around the reagent blank

Reagent blank correction is required. The current manuals allow one blank to be reused for up to one day at room temperature in dark storage, or up to three days refrigerated. Bring a refrigerated blank to room temperature before measurement, and use the same reagent lot for blank and samples. This is a blank-use window, not an extension or guarantee of reagent expiry.

What you need separately

Use a compatible HI83314 or HI83399 photometer, the model-appropriate adapter specified by its current manual, accurate tools for 0.1 mL and 3 mL dosing, clean vial exteriors and suitable PPE. Instruments, adapters and dosing tools are not included. Select the Chloride HR method and follow the manual’s adapter instructions; no physical vial-diameter claim is made here.

Prepare the sample for a useful result

Analyze promptly after collection. The manuals specify sample temperature 20–25 °C and initial sample pH 3–10, with pH below 2 after reagent addition. Filter turbid samples and adequately treat intense color. Bromide and iodide can give high-biased results; consult the full interference limits before interpreting a result. Store unused vials in their packaging at 15–25 °C and follow actual lot instructions and expiry.

Safe handling and shipping review

These are hazardous laboratory reagents, including mercury-thiocyanate vial chemistry and an acidic liquid component. Read both exact-component US SDS before use and arrange appropriate waste handling. Component SDS contain transport classifications; they are not a complete-kit shipping determination. Confirm destination, packaging and carrier requirements before ordering. No air eligibility or blanket ground-only guarantee is made for this offer.

Frequently Asked Questions

Does this measure chlorine or salinity?

Choose this kit for chloride ion (Cl⁻), not free or total chlorine (Cl₂), and not sodium-chloride salinity. The documented range is 80–1000 mg/L as Cl⁻. For expected levels below 100 mg/L, the manuals recommend the lower-range method for improved precision; this page sells only the HR kit.

How many sample tests can I obtain?

One pack contains 25 reagent vials. The current instrument manuals specify reagents for 24 sample tests: a separate reagent blank consumes one vial. Up to 24 sample tests assumes one blank reused within the permitted window; fresh blanks, quality-control checks and repeats consume additional capacity. This is not a promise of 25 independent sample tests.

Why does the bottle say HI96793-0?

Supplied as the HI96794-25 high-range kit: 25 HI96794V-0 reagent vials and HI96793-0 Chloride Reagent bottle. HI96793-0 is the legitimate liquid component of this HR kit, not an alias for the HI96793-25 low-range kit. Total bottle fill volume is not stated here; the 3 mL dose is not a bottle-volume specification.

Which benchtop photometers support this kit?

Use a compatible HI83314 or HI83399 photometer, the model-appropriate adapter specified by its current manual, accurate tools for 0.1 mL and 3 mL dosing, clean vial exteriors and suitable PPE. Instruments, adapters and dosing tools are not included. Select the Chloride HR method and follow the manual’s adapter instructions; no physical vial-diameter claim is made here.

Does the procedure need a digestion heater?

Add 0.1 mL of sample to the sample vial. Slowly add 3 mL of HI96793-0 Chloride Reagent to each sample vial and to the separate blank vial, following the manual’s mixing instructions. Allow 3 minutes for color development, zero with the blank, then read the sample. No external heated digestion or reactor is specified.

How long can I reuse the blank?

Reagent blank correction is required. The current manuals allow one blank to be reused for up to one day at room temperature in dark storage, or up to three days refrigerated. Bring a refrigerated blank to room temperature before measurement, and use the same reagent lot for blank and samples. This is a blank-use window, not an extension or guarantee of reagent expiry.

What sample conditions can affect results?

Analyze promptly after collection. The manuals specify sample temperature 20–25 °C and initial sample pH 3–10, with pH below 2 after reagent addition. Filter turbid samples and adequately treat intense color. Bromide and iodide can give high-biased results; consult the full interference limits before interpreting a result. Store unused vials in their packaging at 15–25 °C and follow actual lot instructions and expiry.

What safety documents and shipping checks are needed?

These are hazardous laboratory reagents, including mercury-thiocyanate vial chemistry and an acidic liquid component. Read both exact-component US SDS before use and arrange appropriate waste handling. Component SDS contain transport classifications; they are not a complete-kit shipping determination. Confirm destination, packaging and carrier requirements before ordering. No air eligibility or blanket ground-only guarantee is made for this offer.

    Product Specifications

    SpecificationDetail
    Manufacturer / catalogHanna Instruments / HI96794-25
    Measured analyteChloride ion (Cl⁻); not chlorine or NaCl salinity
    Range80–1000 mg/L as Cl⁻
    Resolution1 mg/L
    Accuracy±5 mg/L ±6% of reading at 25 °C (instrument method)
    MethodAdaptation of Standard Methods, 24th edition, 4500-Cl⁻ mercury thiocyanate method
    Sample dose0.1 mL per sample vial
    Liquid reagent dose3 mL HI96793-0 per sample vial and per blank vial
    Reaction development3 minutes; no heated digestion
    Pack contents25 HI96794V-0 reagent vials plus HI96793-0 liquid reagent bottle; total bottle volume not asserted
    Sample capacityUp to 24 sample tests with one blank; additional blanks, QC and repeats reduce yield
    Blank reuseUp to 1 day dark room-temperature storage or 3 days refrigerated; same reagent lot; bring to room temperature
    Supported method referencesHI83314 §9.7 and HI83399 §9.15; use model-appropriate adapter
    Unused-vial storageIn packaging at 15–25 °C; actual lot instructions and expiry govern

    Ordering Information

    SpecificationDetail
    HI96794-25One 25-vial high-range chloride reagent kit; up to 24 sample tests after one separate blank

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart