    Match seawater nitrite to the right chemistry and range Use a seawater-specific, matched vial-and-powder method for 0–600 µg/L nitrite-nitrogen as NO₂-N. The pre-dosed format keeps preparation focused on the measured sample and the specified reagent addition, without heated digestion.

    • 0–600 µg/L as NO₂-N
    • 0–0.600 mg/L as N
    • For documented HI83314 and HI83399 vial methods

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

Match seawater nitrite to the right chemistry and range

Use a seawater-specific, matched vial-and-powder method for 0–600 µg/L nitrite-nitrogen as NO₂-N. The pre-dosed format keeps preparation focused on the measured sample and the specified reagent addition, without heated digestion.

Hanna HI96789-25 reagent kit packaging
Factory photograph of the matched reagent format; packaging is illustrative, not a physical contents count.

Select the right method

Choose this set for seawater samples within the documented matrix limits and a nitrite-nitrogen range of 0–600 µg/L. It is not the HI764 marine ultra-low-range Checker refill, a nitrate test or a generic freshwater nitrite reagent.

A matched vial-and-powder workflow

The method combines HI96789V-0 Nitrite in Seawater reagent vial with HI96789-0 reagent powder. The prepared vial avoids making the acidic reagent mixture from bulk chemicals, while the matching packet supplies the color-development addition. The kit is specified for 25 nominal tests; the current US description does not separately itemize the physical packet count.

Zero and read the same sample vial

Add 10 mL sample to the reagent vial, cap and invert several times. Zero this sample-filled vial, then add one HI96789-0 packet and shake gently for 90 seconds. Allow 15 minutes for color development and read using the named instrument method. No heated reactor or digestion step is specified. Follow the full manual and the instructions for the supplied lot.

Keep nitrogen and nitrite mass distinct

The primary 0–600 µg/L range is as NO₂-N: nitrogen in nitrite. It equals 0–0.600 mg/L as N, not 0–600 µg/L as nitrite ion. The instrument’s chemical-form conversion changes the numerical reporting basis; do not relabel the same number as NO₂⁻ mass.

Check the seawater matrix before selecting

The manuals report testing with synthetic seawater ASTM D665 and identify chloride above 24000 mg/L as an interference. Other listed limits include sodium above 10000 mg/L, sulfate above 3000 mg/L and magnesium above 2500 mg/L. Seawater labeling does not mean every concentrated brine is suitable; review the complete interference table.

Provide the optical setup, not a heater

Use the HI83314 or HI83399 Nitrite Seawater vial method with the adapter specified by that instrument, accurate 10 mL sample transfer, timing and clean vial surfaces. The US format name and instrument method headings use different diameter conventions; compatibility here is based on the named procedures, not an asserted physical diameter. Instruments and preparation accessories are separate. Store unused vials in their packaging in a cool, dark place.

Compatibility and responsible handling

The named vial procedures are documented for HI83314 and HI83399. Use the method and adapter specified for your instrument. Review every matching component SDS and your actual lot instructions. Photometer, accessories and handling equipment are separate.

Frequently Asked Questions

Why choose this instead of an ordinary nitrite reagent?

It is the documented seawater vial-and-powder method, with matrix-specific interference limits. Select by your required matrix, range and instrument method rather than assuming interchangeability with freshwater kits.

Does 600 µg/L mean nitrite ion mass?

No. The primary range is 0–600 µg/L as NO₂-N, equivalent to 0–0.600 mg/L as nitrogen. Nitrite-ion mass requires a conversion and does not retain the same number.

Is this a refill for the HI764 marine ULR Checker?

No. This is HI96789-25 for the documented seawater vial methods, not HI764-25. The instruments, ranges and reagent formats are different.

How many tests are available after zeroing?

25 nominal tests. The sample-filled vial is zeroed before powder addition, so no extra sacrificial blank vial is deducted. QC and repeats consume reagents.

Is adding sample the only preparation step?

No. Add 10 mL sample and zero the vial, then add one HI96789-0 powder packet, shake gently for 90 seconds and allow 15 minutes of development before reading.

Do I need a heated reactor?

No. The direct seawater nitrite procedure specifies mixing and 15-minute color development, not heated digestion.

Which instruments and vial adapter are supported?

HI83314 and HI83399 directly document HI96789-25. Select their Nitrite Seawater vial method and the adapter specified in the instrument manual; no physical diameter or unverified SKU alias is inferred here.

Can I use it for concentrated brine?

Not without checking the full matrix limits. Chloride above 24000 mg/L can interfere, along with other ions listed in the manuals. The documented test matrix is synthetic seawater ASTM D665.

    Product Specifications

    SpecificationDetail
    Manufacturer catalog numberHI96789-25
    Parameter and matrixNitrite-nitrogen in seawater
    Primary range0–600 µg/L as NO₂-N
    Equivalent nitrogen range0–0.600 mg/L as N
    Resolution1 µg/L as N
    Capacity25 nominal tests; same-vial zero/read
    Per-test preparation10 mL sample; 1 HI96789V-0 vial; 1 HI96789-0 packet
    Mixing and developmentShake gently 90 seconds; develop 15 minutes
    HeatingNo heated digestion
    Chloride interferenceAbove 24000 mg/L chloride
    MethodDiazotization adaptation, Standard Methods 23rd edition
    Supported direct vial methodsHI83314 and HI83399; method-appropriate adapter required

    Ordering Information

    SpecificationDetail
    HI96789-25One reagent set for 25 nominal tests

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.