Hanna HI96788-25 Phenols Pre-dosed Reagent Set — 25 Tests Default Title Photometer Reagents Hanna Instruments
Hanna HI96788-25 Phenols Pre-dosed Reagent Set — 25 Tests Default Title Photometer Reagents Hanna Instruments

Hanna HI96788-25 Phenols Pre-dosed Reagent Set — 25 Tests

$126.49

    Matched phenols chemistry for routine water testing. HI96788-25 is a pre-dosed reagent set for 25 nominal tests using the documented 4-aminoantipyrine method.

    • 0.00–5.00 mg/L phenols; 510 nm
    • Direct method support: HI83314 and HI83399
    • Plan separate meter, method-specific adapter, sample tools and QC standards

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

Keep the named phenols method ready for the next water sample

Choose HI96788-25 when you need a matched, pre-dosed phenols reagent set rather than a single replacement component. The 25-test format supports routine water-quality and treatment checks with less reagent preparation, while lot and expiry labeling supports traceability.

Hanna HI96788-25 Phenols reagent set with branded vials and packets
Official reagent-set photograph; identify supplied components by their lot labels, not pictured quantities or dates.

Match the phenols method—not just the vial format

Use the documented Phenols method on HI83314 or HI83399 for 0.00–5.00 mg/L phenols, using the 510 nm 4-aminoantipyrine color reaction. The set is intended for drinking water, wastewater, process water and natural waters within the method’s matrix limits.

One set, 25 nominal determinations

One order supplies the HI96788-25 reagent set for 25 tests. Each determination uses a HI96788V-0 Phenol Reagent Vial, one HI96788A-0 packet and one HI96788B-0 packet. Quality-control checks and repeats also consume reagents; 25 tests does not mean 25 independently validated sample results. Per-test doses are not a claim about retail component counts or vial fill volumes.

Have the measurement workflow ready

Use your compatible photometer with the adapter specified in its current Phenols method, accurate 5 mL sample delivery, clean lint-free wipes and appropriate PPE. Meter, adapter, pipette and reference standards are separate from this reagent refill. Do not add a digestion reactor simply because the reagent is supplied in vials; the cited phenols color-development procedure has no heated digestion step.

A practical preparation overview

The method zeroes the sample-containing reagent vial before adding reagents A and B, then measures after color development. Keep sample temperature between 10 and 35 °C and allow the prescribed five-minute reaction time. Follow the exact-model manual for the complete sequence, vial handling and timing rather than using this overview as a bench recipe.

Read phenols results on the right basis

HI83399 reports mg/L of phenols as C6H5OH, with phenol as the standard. Different phenolic compounds produce different color responses; Hanna describes the measurement as the minimum reported concentration of phenols. This is not equal-response quantification of every phenolic compound, chemical speciation or a direct toxicity measurement.

Choose preparation and quality control for your matrix

Sample zeroing helps address background, but it does not make every matrix interference-free. High turbidity requires distillation in the current method; oxidizing/reducing agents and listed ions can also interfere. Hanna’s ISO 6439 / EPA 420.1 compliance statement is qualified after distillation, not a guarantee that an untreated sample or every reporting use is accepted. Use appropriate phenol reference material and laboratory QC separately; instrument check standards do not replace analytical QC.

Store and handle by the supplied lot

Keep unused vials in their packaging in a cool, dark place and use the expiry and storage directions on the supplied lot. Read all three component SDS before handling and follow their PPE and waste-disposal guidance. The manufacturer classifies this product as Dangerous Goods; destination and carrier eligibility require confirmation, not an assumed dispatch promise.

Frequently Asked Questions

Why choose the complete HI96788-25 set rather than one component?

The set is the orderable 25-test refill named in the HI83314 and HI83399 Phenols methods. A determination needs the reagent vial plus both reagents A and B. A component SDS or a bottle bearing a related code does not establish a complete assay refill.

How many assays can I plan from one order?

Hanna states 25 tests. Plan reagent use for your samples plus blanks, controls and repeats required by your laboratory method. The stated capacity is not a promise of 25 reportable unknowns, and per-test doses are not used here to infer physical packet counts or total liquid volume.

Which instrument and vial setup should I use?

HI83314 and HI83399 current manuals explicitly list HI96788-25 for their Phenols method and specify the model’s vial-adapter setup. Hanna markets the set as 13 mm internal-diameter vials; the current instrument procedure is labeled Phenols (16 mm Vial). Follow that exact model procedure and adapter instructions rather than treating diameter labels as an adapter alias or universal photometer compatibility.

What range and chemistry does this reagent measure?

The corroborated phenols method is 0.00–5.00 mg/L, with 0.01 mg/L resolution and a 510 nm 4-aminoantipyrine reaction. The HI83314 and HI83399 method accuracy is ±0.05 mg/L ±3% of reading at 25 °C. This is phenols chemistry, not a nitrite reagent or a nitrogen-reporting range.

Does a result represent every phenolic compound equally?

No. Different phenolic compounds yield varying color responses. Phenol is the reference standard, and HI83399 displays mg/L phenols as C6H5OH. Hanna describes the result as the minimum reported phenols concentration; do not present it as full phenolic speciation, an equal-response sum of all phenols or a toxicity result.

Does the method require a reactor or distillation?

The cited color-development procedure does not require a digestion reactor. Distillation is a separate sample-preparation requirement for high turbidity and may be used to remove other interferences. Hanna’s stated ISO 6439 / EPA 420.1 compliance is after distillation. A vial format alone does not imply COD digestion.

What else do I need, including standards?

Have the supported meter, its method-specified vial adapter, accurate 5 mL sample delivery, wipes and SDS-directed PPE. These are not represented as included in the refill. Provide appropriate phenol reference material and the blanks/controls required by your laboratory; CAL Check instrument verification material is not an analytical phenol standard. Check the method’s interference limits against your sample matrix.

Which handling and timing details protect the result?

Use samples at 10–35 °C, keep vial exteriors clean, zero as directed and observe the five-minute color-development period. Store unused vials in their packaging in a cool, dark place and follow the supplied lot expiry. Read the HI96788V-0, HI96788A-0 and HI96788B-0 SDS and the full method for safe handling, waste management and matrix preparation.

    Product Specifications

    SpecificationDetail
    Catalog numberHI96788-25
    Analyte / reporting basisPhenols; HI83399 reports mg/L as C6H5OH, phenol reference standard
    Range0.00–5.00 mg/L
    Resolution0.01 mg/L
    HI83314 / HI83399 method accuracy±0.05 mg/L ±3% of reading at 25 °C
    Method / wavelengthAdaptation of 4-aminoantipyrine method EPA 420.1; 510 nm
    Sample volume / temperature5.0 mL; 10–35 °C
    Color-development time5 minutes after reagent additions, per exact-model procedure
    Per determinationHI96788V-0: 1 vial; HI96788A-0: 1 packet; HI96788B-0: 1 packet
    Capacity25 nominal tests; QC and repeats consume reagents
    Vial / adapter selectionManufacturer: 13 mm internal diameter; follow the exact instrument Phenols method and adapter instructions
    Matrix preparationHigh turbidity: distillation required; consult full method for ion and redox interferences
    Instrument method supportHI83314 and HI83399; no universal vial compatibility implied

    Ordering Information

    SpecificationDetail
    HI96788-25Phenols pre-dosed reagent set — 25 tests; photometer, adapter, sample-delivery tools and standards separate

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.