Hanna HI95762 Free Chlorine Ultra Low Range Reagents, 100/300 Tests Photometer Reagents Hanna Instruments
Hanna HI95762 Free Chlorine Ultra Low Range Reagents, 100/300 Tests Photometer Reagents Hanna Instruments

Hanna HI95762 Free Chlorine Ultra Low Range Reagents, 100/300 Tests

$40.69

    Keep trace free-chlorine checks on the right scale. Replenish your established photometer workflow with pre-measured Hanna powder chemistry.

    • HI95762-01: 100 tests; HI95762-03: 300 tests
    • HI97762 method: 0.000 to 0.500 mg/L as Cl₂
    • Reagents only; meter, cuvettes and CAL Check standards separate

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Keep trace free-chlorine checks on the right scale.

Replenish ultra-low-range free-chlorine testing with the DPD powder made for your HI97762 workflow. Pre-measured packets make dosing straightforward; 100- and 300-test packs let you match replenishment to the number of samples you actually run.

Hanna HI95762 official manufacturer reagent reference packaging
Official Hanna reference packaging. Printed lot numbers and expiration dates are illustrative, not the dates of supplied stock.

Match the method before the pack size

Choose HI95762-01 or HI95762-03 for HI97762 FREE chlorine ultra low range testing: 0.000 to 0.500 mg/L as Cl₂. This is not HI95761 total-chlorine ULR chemistry, a general higher-range chlorine refill or a CAL Check standard.

A defined reaction and reporting basis

Free chlorine reacts with DPD to develop a pink tint, measured photometrically and reported as Cl₂ equivalents. The result is free chlorine, not total chlorine. A 0.500 mg/L upper limit makes method selection important: a larger test pack does not turn this into a higher-range measurement.

Where this refill fits

Suited to an established drinking-water testing program that needs a free-chlorine result within the ultra-low range. If the required result is total chlorine or the expected concentration exceeds this method’s range, select the appropriate separate chemistry and instrument method instead.

Know when the sample needs pretreatment

The US HI95762-0 SDS identifies drinking-water samples as its intended use. Bromine, chlorine dioxide, iodine, ozone and oxidized chromium or manganese can interfere. For hardness above 500 mg/L as CaCO₃, the HI97762 manual calls for approximately two minutes of shaking after adding the reagent. Do not infer universal seawater or high-salinity suitability from the chlorine parameter name.

Color may develop incompletely or fade rapidly above these limits: bicarbonate alkalinity of 1000 mg/L as CaCO₃ at pH below 8.3, carbonate alkalinity of 25 mg/L as CaCO₃ at pH above 9.0, or acidity of 150 mg/L as CaCO₃. The HI97762 method specifies neutralization with diluted HCl or NaOH to remove this interference. Follow the complete pretreatment instructions; do not add an arbitrary neutralizer dose.

What the selected pack supplies

HI95762-01 contains pre-measured HI95762-0 powder reagent for 100 tests; HI95762-03 provides 300 tests. One determination consumes one packet. Test capacity refers to analytical use, not a count of reusable cuvettes or instruments.

What to have ready separately

Have a compatible photometer, clean cuvettes with stoppers and caps, a representative sample and the accessories required by the method. None is included in this reagent refill. CAL Check standards are separate instrument-verification materials, not replacements for the sample reagent.

Run the measurement in sequence

Fill a clean cuvette with 10 mL of unreacted sample, fit the stopper and cap, align the cap notch and zero the HI97762. Add one packet of HI95762-0, close the cuvette and shake gently for about 20 seconds. Reinsert it in the correct orientation and use the one-minute countdown before reading. Apply the manual’s specific matrix treatments where required.

Choose for your testing schedule

Select the 100-test HI95762-01 for smaller sampling workloads or the 300-test HI95762-03 for more frequent use. Include repeat measurements and quality-control work in your planning, and choose a quantity you can use within the expiration date on the supplied lot.

Other documented instrument methods

Exact-model Hanna manuals also list both packs for HI83300, HI83399. Select the matching free chlorine ultra low range method and follow that model’s procedure. The detailed range and workflow above refer to HI97762.

Frequently Asked Questions

What is the difference between the two packs?

HI95762-01 supplies 100 tests and HI95762-03 supplies 300. Both use HI95762-0 powder, one packet per determination. Choose by sampling workload and likely use before the marked expiration date, not by range.

Will HI95762 measure total chlorine?

No. It is the FREE chlorine ultra low range family for HI97762. HI95761 is a different total-chlorine ULR family. Do not substitute based on a similar catalog number or the same test count.

What range and reporting basis does HI97762 use?

The range is 0.000 to 0.500 mg/L as Cl₂. This expresses a free-chlorine result on a chlorine-equivalent basis; it does not make the measurement total chlorine. Both pack sizes have the same range.

How do I run the normal HI97762 sequence?

Use 10 mL of unreacted sample to zero, then add one HI95762-0 packet. Close and shake gently for about 20 seconds and run the one-minute countdown. Follow the method’s cuvette orientation, timing and matrix-treatment instructions.

When is neutralization or extra shaking required?

The HI97762 method calls for diluted HCl or NaOH neutralization when the specified alkalinity or acidity limits are exceeded. Those limits are above 1000 mg/L as CaCO₃ for bicarbonate at pH below 8.3, above 25 mg/L as CaCO₃ for carbonate at pH above 9.0, or acidity above 150 mg/L as CaCO₃. Hardness above 500 mg/L as CaCO₃ calls for approximately two minutes of shaking after reagent addition. Use the full manual before treatment.

Can other disinfectants affect the reading?

Yes. Bromine, chlorine dioxide, iodine, ozone and oxidized chromium or manganese can interfere. The US SDS identifies drinking-water samples as the intended use; these documents do not establish universal seawater or high-salinity suitability.

Which photometers and accessories do I need?

HI97762 is the primary portable method. Exact-model manuals also document both packs for HI83300 and HI83399. The photometer, cuvettes, stoppers, caps, preparation accessories and CAL Check standards are separate; select the free-chlorine ULR method on a multiparameter meter.

What should I check on a new pack?

Confirm HI95762-0 reagent identity, the lot number and expiration date on the supplied packets, and review its linked US Safety Data Sheet for handling, storage and disposal. Keep sample-testing reagents separate from CAL Check instrument standards.

    Product Specifications

    SpecificationDetail
    BrandHanna Instruments
    ParameterFree Chlorine Ultra Low Range
    Catalog numbersHI95762-01; HI95762-03
    Test capacities100 tests / 300 tests
    Reagent formPre-measured powder packets
    Reagent componentHI95762-0
    Reference portable meterHI97762
    Range and reporting basis on HI977620.000 to 0.500 mg/L as Cl₂
    MethodAdaptation of Standard Methods, 18th edition, 4500-Cl G, DPD colorimetric method
    Sample volume on HI9776210 mL
    Reagent per determinationOne packet of HI95762-0
    Normal mixing and readingGentle shaking about 20 seconds; normal reaction countdown 1 minute
    Other documented metersHI83300, HI83399
    IncludedReagents only; meter, cuvettes, caps, stoppers and standards separate
    TraceabilityLot number and expiration date on each packet
    Intended sample use (US SDS)Free chlorine determination in drinking-water samples
    Matrix treatmentSpecified alkalinity/acidity limits: diluted HCl or NaOH neutralization; hardness above 500 mg/L as CaCO₃: about 2 minutes shaking after reagent addition

    Ordering Information

    Catalog NumberPack Contents
    HI95762-01100 tests — HI95762-0 powder reagent
    HI95762-03300 tests — HI95762-0 powder reagent

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.