    Choose the lower ammonia-nitrogen range For lower-concentration ammonia nitrogen, this 16 mm vial set gives your supported photometer a 0.00–3.00 mg/L as NH₃-N method with 0.01 mg/L resolution.

    • 0.00–3.00 mg/L as NH₃-N
    • 0.01 mg/L as NH₃-N
    • For the HI83314 and HI83399 16 mm vial methods

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

Choose the lower ammonia-nitrogen range

For lower-concentration ammonia nitrogen, this 16 mm vial set gives your supported photometer a 0.00–3.00 mg/L as NH₃-N method with 0.01 mg/L resolution.

Hanna HI93764A-25 reagent kit packaging
Official Hanna product photograph; lot dates and packaging are illustrative.

Select the right method

Choose ammonia LR for the NH₃-N reporting basis and expected range. This is not total nitrogen, nitrate, a direct free-ammonia-only reading or a generic non-vial reagent.

25 tests with the sample vial as zero

The manufacturer identifies 25 HI93764A-0 reagent vials and one bottle of HI93764-0 Nessler reagent. The same sample-containing vial is zeroed before adding Nessler reagent, so no separate blank vial is deducted. QC and repeats use additional reagents.

A direct, unheated method

Select Ammonia LR (16) and fit the 16 mm adapter. Add 5 mL sample to the vial, cap and invert; insert and zero. Add four drops of Nessler reagent, cap and invert, then time 3 minutes 30 seconds and read. No heated digestion is required. Follow the full manual and actual lot instructions.

Consider the sample matrix

Hardness above 1 g/L, iron and sulfide may interfere; organic compounds including acetone above 0.1%, alcohols, aldehydes, amines, chloramines, glycine or urea above 10 mg/L can interfere. The manual specifies distillation to remove organic interference. This is a pretreatment question, not a heated digestion step.

Arrange compatible equipment and safe handling

Use HI83314 or HI83399 with a 16 mm adapter and an accurate 5 mL measuring tool. Nessler reagent contains mercury; review component SDS, use specified PPE and plan appropriate chemical waste disposal. Store unused vials in their packaging in a cool dark place.

Compatibility and responsible handling

The direct 16 mm vial method is documented for HI83314 and HI83399. Confirm your instrument and adapter before ordering. The manufacturer identifies this offer as dangerous goods and says dangerous goods can ship only by ground; confirm destination and carrier restrictions. Follow the current component safety data sheets and the instructions for your actual lot. Photometer, accessories and handling equipment are separate.

Frequently Asked Questions

What does the result represent?

Ammonia nitrogen as NH₃-N. This is not a total-nitrogen or nitrate test, and is not a species-selective free NH₃-only reading.

What is the reporting basis for the stated range?

The 0.00–3.00 mg/L range is as NH₃-N. A meter conversion to NH₃ or NH₄⁺ changes the numerical reporting basis.

How many tests are in the pack?

The set is specified for 25 tests. The same sample vial is zeroed before Nessler addition; QC and repeats consume reagents.

Does the method require heated digestion?

No. The vial method has no reactor or digestion step. Distillation may be required as sample pretreatment for specified organic interferences.

What are the preparation steps?

Add 5 mL sample, cap and mix, zero, add four drops Nessler reagent, mix and read after 3 minutes 30 seconds. Follow the instrument manual.

Which meters work with this set?

The HI83314 and HI83399 manuals directly identify this reagent for their Ammonia LR (16) method. A 16 mm adapter is required.

What sample interferences should I check?

Hardness above 1 g/L, iron, sulfide and specified organic compounds may interfere. Consult the manual for treatment and suitability of your matrix.

What safety precautions matter?

The Nessler reagent contains mercury. Review both component SDS and your lot instructions; use required PPE and an appropriate chemical waste process.

    Product Specifications

    SpecificationDetail
    Manufacturer catalog numberHI93764A-25
    ParameterAmmonia nitrogen, NH₃-N
    Range0.00–3.00 mg/L as NH₃-N
    Resolution0.01 mg/L as NH₃-N
    Pack25 HI93764A-0 vials and one bottle HI93764-0 Nessler reagent
    Sample5 mL per vial
    Read time3 minutes 30 seconds after Nessler addition
    HeatNo heated digestion
    MethodASTM D1426 Nessler method adaptation
    Supported direct vial methodsHI83314 and HI83399; 16 mm adapter required

    Ordering Information

    SpecificationDetail
    HI93764A-2525 HI93764A-0 vials and one bottle HI93764-0 Nessler reagent

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.