Hanna HI93740 Nickel Low Range Reagents, 50/150 Tests Photometer Reagents Hanna Instruments
Hanna HI93740 Nickel Low Range Reagents, 50/150 Tests Photometer Reagents Hanna Instruments

Hanna HI93740 Nickel Low Range Reagents, 50/150 Tests

$273.90

    Refill low-range nickel testing without changing chemistry. Mixed powder/liquid reagent replenishment for an existing setup; verify dispersant supply before use.

    • HI93740-01: 50 tests; HI93740-03: 150 tests
    • HI97740 method: 0.000 to 1.000 mg/L as Ni
    • Prepared-blank PAN method; dispersant conditional for turbidity

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Refill low-range nickel testing without changing chemistry.

Choose HI93740-01 for 50 tests or HI93740-03 for 150 tests. This mixed powder-and-liquid PAN reagent family replenishes an established nickel low range photometer workflow. The larger pack increases test capacity, not measuring range; these are not 100- or 300-test packs.

Hanna generic reagent packet reference photograph
Manufacturer’s generic reagent-packet photograph, not the full mixed powder/liquid set or an itemized contents image. Printed 09/2022 date is illustrative, not the expiration of supplied stock.

Match the instrument, method and reporting basis

Use the HI97740 nickel low range method, reporting 0.000 to 1.000 mg/L as Ni. Match the nickel parameter and low-range PAN procedure: this is not an iron reagent or an interchangeable high-range nickel refill.

PAN chemistry with a prepared blank

An adaptation of the 1-(2-pyridylazo)-2-naphthol (PAN) method develops an orange tint. A reacted deionized-water blank and a separately reacted sample are both required; an untreated sample is not the method blank.

Reagent consumption per complete test

HI93740A-0 and HI93740C-0 powders are used with HI93740B-0 liquid. Each complete determination consumes two A packets, 2 mL B and two C packets in total, shared across a 25 mL deionized-water blank and a separate 25 mL sample preparation.

Check the dispersant before testing

HI93703-51 is not a routine addition to the nickel method. If turbidity develops above 30 °C, the HI97740 manual calls for two to three drops per cuvette before zeroing and reading. Confirm the selected pack’s contents and your dispersant supply if that treatment is needed.

Follow the measurement sequence

Prepare 25 mL deionized water and 25 mL sample in separate graduated beakers. Add one A packet to each and dissolve fully, especially if ferric iron is present. Add 1 mL B to each, mix and allow the 15-minute reaction before adding one C packet to each and dissolving. Transfer 10 mL of the prepared blank and reacted sample to separate cuvettes, zero with the blank and read the sample. Treat turbidity as directed before zeroing.

Prepare the rest of the setup

Have a compatible photometer, clean cuvettes with caps and stoppers, deionized water and suitable volume-measuring equipment available separately. The nickel procedure also needs two graduated beakers. CAL Check standards verify the instrument; they do not replace sample-reaction reagents. Plan pack use around the supplied lot’s expiration date, repeat measurements and quality-control needs.

Check the sample matrix

The nickel method lists matrix restrictions, including chloride above 8000 mg/L and ferric iron above 10 mg/L; cobalt and ferrous iron must not be present. Dissolve reagent A completely when ferric iron is present. Check all listed limits in the manual rather than assuming suitability for every mixed-metal or seawater sample.

Frequently Asked Questions

Which pack size should I order?

HI93740-01 provides 50 tests; HI93740-03 provides 150 tests. Order quantity 1 for one selected sellable pack. Capacity refers to complete determinations, not the number of individual powder packets or bottles.

Which instrument and mode are verified?

Use the HI97740 nickel low range method, reporting 0.000 to 1.000 mg/L as Ni. Match the nickel parameter and low-range PAN procedure: this is not an iron reagent or an interchangeable high-range nickel refill.

What chemistry and units does the method use?

An adaptation of the 1-(2-pyridylazo)-2-naphthol (PAN) method develops an orange tint. A reacted deionized-water blank and a separately reacted sample are both required; an untreated sample is not the method blank. The HI97740 method range is 0.000 to 1.000 mg/L as Ni.

How much reagent is used per determination?

HI93740A-0 and HI93740C-0 powders are used with HI93740B-0 liquid. Each complete determination consumes two A packets, 2 mL B and two C packets in total, shared across a 25 mL deionized-water blank and a separate 25 mL sample preparation.

Is dispersing agent needed, and is it included?

HI93703-51 is not a routine addition to the nickel method. If turbidity develops above 30 °C, the HI97740 manual calls for two to three drops per cuvette before zeroing and reading. Confirm the selected pack’s contents and your dispersant supply if that treatment is needed.

What is the blank and reaction sequence?

Prepare 25 mL deionized water and 25 mL sample in separate graduated beakers. Add one A packet to each and dissolve fully, especially if ferric iron is present. Add 1 mL B to each, mix and allow the 15-minute reaction before adding one C packet to each and dissolving. Transfer 10 mL of the prepared blank and reacted sample to separate cuvettes, zero with the blank and read the sample. Treat turbidity as directed before zeroing.

Can other metals or sample salts affect the reading?

The nickel method lists matrix restrictions, including chloride above 8000 mg/L and ferric iron above 10 mg/L; cobalt and ferrous iron must not be present. Dissolve reagent A completely when ferric iron is present. Check all listed limits in the manual rather than assuming suitability for every mixed-metal or seawater sample.

What should I have ready before opening a pack?

Have a compatible photometer, clean cuvettes with caps and stoppers, deionized water and suitable volume-measuring equipment available separately. The nickel procedure also needs two graduated beakers. CAL Check standards verify the instrument; they do not replace sample-reaction reagents. Plan pack use around the supplied lot’s expiration date, repeat measurements and quality-control needs. Review the component-specific US Safety Data Sheets and the instrument method manual before handling or disposal. This listing is reagent replenishment, not a promise that every startup item is supplied.

    Product Specifications

    SpecificationDetail
    BrandHanna Instruments
    ParameterNickel Low Range
    Catalog numbersHI93740-01; HI93740-03
    Test capacity50 or 150 complete tests, according to selected pack
    FormatMixed powder and liquid reagents
    MethodAdaptation of 1-(2-pyridylazo)-2-naphthol (PAN); orange tint
    Primary verified instrumentHI97740 nickel LR method
    Range on HI977400.000 to 1.000 mg/L as Ni
    Blank and sample25 mL deionized water blank and 25 mL sample; 10 mL read aliquots
    Total A/B/C per determination2 A packets; 2 mL B; 2 C packets
    Dispersing agent HI93703-51Conditional for turbidity: 2–3 drops per cuvette
    Reaction timing15 minutes after B, before C
    Dispersing-agent supplyHI93703-51 is conditional for turbidity treatment. Confirm the selected pack contents and available supply if needed.
    Instrument and setupPhotometer, cuvettes, caps, stoppers, measuring equipment, deionized water and CAL Check standards separate

    Ordering Information

    SpecificationDetail
    HI93740-0150 tests — Nickel Low Range reagent pack
    HI93740-03150 tests — Nickel Low Range reagent pack

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.