Hanna HI93739 Fluoride High Range Reagents, 100/300 Tests Photometer Reagents Hanna Instruments
Hanna HI93739 Fluoride High Range Reagents, 100/300 Tests Photometer Reagents Hanna Instruments

Hanna HI93739 Fluoride High Range Reagents, 100/300 Tests

$153.99

    Keep high-range fluoride testing ready for the next sample Keep HI97739 water-sample testing supplied with the complete matched fluoride high range reagent set.

    • HI93739-01: 100 tests; HI93739-03: 300 tests
    • HI97739: 0.0–20.0 mg/L as fluoride (F−)
    • Reagents only; meter, cuvettes and CAL Check standards separate

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

HANNA PHOTOMETER REAGENTS · HI93739

Keep high-range fluoride testing ready for the next sample

Replenish the matched liquid chemistry for fluoride measurements with Hanna HI93739. Choose a nominal 100-test or 300-test set for the same SPADNS method, with HI97739 as the primary instrument reference. Plan the sample preparation as carefully as the reagent supply: wastewater and seawater require distillation before measurement.

Official Hanna HI93739 reagent set reference photo
Manufacturer reference photo shows the liquid reagent system. Bottle number, fill volumes and pictured accessories are not a confirmed packing list; choose by nominal test capacity.

Match the method, not just the element name

HI97739: 0.0–20.0 mg/L as fluoride (F−). Two liquid components: HI93739A-0 and HI93739B-0. Not fluoride low-range or Checker chemistry.

What the selected pack supplies

HI93739-01 and HI93739-03 are complete matched fluoride high-range reagent sets with manufacturer-nominal capacities of 100 and 300 tests. The method uses liquid A and B; physical bottle counts and fill volumes are not independently itemized here.

Where this method fits

Use this high-range method when the expected fluoride concentration and sample matrix suit the HI97739 procedure. It is not an unrestricted direct field test for wastewater or seawater: arrange the required distillation before analysis. The reagent family is also documented for HI83300 and HI83399; use each instrument’s own procedure.

The HI97739 workflow at a glance

Using separate liquid-handling tools as directed, add 2 mL of HI93739A-0 and 8 mL of HI93739B-0 to the cuvette. Cap, invert to mix, and allow the one-minute countdown before zeroing. Add 1 mL of unreacted, appropriately prepared sample with a second syringe, cap and invert, then use the one-minute read countdown. This overview does not replace the complete instrument procedure.

Check the sample matrix

Distillation is required for wastewater and seawater. Highly colored or turbid samples may also require distillation. The manual lists interference above: alkalinity 5000 mg/L as CaCO3, chloride 700 mg/L, sulfate 200 mg/L, orthophosphate 16 mg/L, aluminum 0.1 mg/L, ferric iron 10 mg/L and sodium hexametaphosphate 1.0 mg/L. Highly alkaline samples can be neutralized with nitric acid following the manual and appropriate laboratory precautions.

Choose a pack around your workload

HI93739-01 supplies 100 tests; HI93739-03 supplies 300 tests. The larger pack supplies three times the determinations, not a different measuring range. One order quantity means one complete selected pack. Choose by testing frequency and the lot/expiry markings on supplied stock.

What to have beside the reagent set

Supply the compatible photometer, cuvettes with stoppers and caps, and the measuring/dispensing accessories required by the method separately. CAL Check standards are separate instrument-verification materials, not replacements for sample reagents.

Handling before you begin

Review both current US component SDS documents before use. Use the PPE, ventilation, storage and disposal precautions in those documents and keep reagent dispensing separate from sample dispensing. Check the supplied lot and expiry markings. Hanna marks these offers as Dangerous Goods, with ground shipment only.

Use the linked HI97739 instrument manual as the method reference for the complete procedure, precautions and instrument operation. This is not a separate reagent instruction manual.

Frequently Asked Questions

Should I choose 100 or 300 tests?

HI93739-01 supplies 100 tests; HI93739-03 supplies 300 tests. Both are complete reagent sets for the same method. Choose by expected workload and marked expiry dates, not by a different analytical range.

Is this the low-range fluoride reagent?

No. HI93739 is the fluoride high-range reagent system. The HI97739 method covers 0.0–20.0 mg/L as F−. Do not substitute low-range or Checker reagents based only on the analyte name.

Can I measure seawater or wastewater directly?

No. The HI97739 manual requires distillation before measuring wastewater or seawater. Highly colored or turbid samples may also need distillation. Confirm preparation facilities before ordering for these matrices.

What must I provide for liquid handling?

The procedure calls for separate 1 mL syringes for reagent A and sample, plus the specified pipette and tip for reagent B. Do not infer these are included from the reference photo; provide the required accessories and any distillation equipment separately.

Does a 300-test set mean a known bottle count?

No. The manufacturer publishes nominal test capacity. This page does not infer bottle counts or fill volumes. Both liquid components must be used in the specified proportions for each determination.

Which photometers are documented for HI93739?

Both packs are documented for HI97739, HI83300, HI83399. The procedure and range on this page use HI97739 as the primary reference; follow the exact instrument method when using another model.

Which sample conditions should I check first?

Distillation is required for wastewater and seawater. Highly colored or turbid samples may also require distillation. The manual lists interference above: alkalinity 5000 mg/L as CaCO3, chloride 700 mg/L, sulfate 200 mg/L, orthophosphate 16 mg/L, aluminum 0.1 mg/L, ferric iron 10 mg/L and sodium hexametaphosphate 1.0 mg/L. Highly alkaline samples can be neutralized with nitric acid following the manual and appropriate laboratory precautions.

Are the instrument, cuvettes and CAL Check standards included?

No. These are reagent-only packs. Provide the photometer, cuvettes with stoppers and caps, and the method-required sampling and dispensing accessories separately. CAL Check standards are separate instrument-validation materials, not test reagents.

    Product Specifications

    SpecificationDetail
    ParameterFluoride High Range
    Reagent formatTwo-component liquid reagent system
    MethodSPADNS; adaptation of Standard Methods, 18th Edition
    Primary instrumentHI97739
    Range and reporting basis0.0–20.0 mg/L as fluoride (F−)
    Documented instrumentsHI97739, HI83300, HI83399
    Reagent doseHI93739A-0: 2 mL; HI93739B-0: 8 mL per determination
    Sample and zero preparationZero the mixed A/B reagent; then add 1 mL prepared sample using a second syringe
    Timing on HI977391 minute before zero; 1 minute before reading
    MatrixDistillation is required for wastewater and seawater. Highly colored or turbid samples may also require distillation. The manual lists interference above: alkalinity 5000 mg/L as CaCO3, chloride 700 mg/L, sulfate 200 mg/L, orthophosphate 16 mg/L, aluminum 0.1 mg/L, ferric iron 10 mg/L and sodium hexametaphosphate 1.0 mg/L. Highly alkaline samples can be neutralized with nitric acid following the manual and appropriate laboratory precautions.
    Pack contentsHI93739-01 and HI93739-03 are complete matched fluoride high-range reagent sets with manufacturer-nominal capacities of 100 and 300 tests. The method uses liquid A and B; physical bottle counts and fill volumes are not independently itemized here.
    Separate requirementsCompatible meter, cuvettes, stoppers, caps, method-required sample/dispensing accessories and CAL Check standards
    Shipping limitationDangerous Goods; ground shipment only

    Ordering Information

    Catalog numberComplete reagent pack
    HI93739-01100 tests — complete fluoride high range reagent set
    HI93739-03300 tests — complete fluoride high range reagent set

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.