    • 400–750 mg/L as CaCO₃ total calcium + magnesium hardness
    • 100 complete tests with HR-specific liquid Reagent A
    • HI97735 zero/read sequence and four US component SDS linked

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

Match harder-water samples to the high-range reagent set.

Replenish your total-hardness workflow with a complete, range-specific reagent pack for 100 tests. HI93735-02 is the high-range chemistry for 400–750 mg/L as CaCO₃: a focused refill for a compatible photometer, not a different pack size of another hardness method.

Official Hanna HI93735-02 total hardness reagent packaging
Official Hanna HI93735-02 product photograph. Packaging, labels, lot markings and printed dates are illustrative, not a promise of current-stock expiry or an itemized pack inventory.

Match the refill to the complete method

Choose HR for 400–750 mg/L as CaCO₃. The HI97735 has separate LR, MR and HR programs, with a different Reagent A for each range. Select the matching method and reagent set together; overlapping ranges do not make the chemistries interchangeable.

Measure combined calcium and magnesium hardness

This method reports total calcium plus magnesium hardness on a calcium-carbonate-equivalent basis. A reading in mg/L as CaCO₃ is not a direct calcium-ion concentration, a calcium-only hardness result or a measurement of total dissolved solids. Keep the reporting basis consistent when comparing results or tracking changes in water treatment.

One complete range-specific refill

The 100-test pack supports the HR method using liquid HI93735IND-0 indicator, liquid HI93735A-HR Reagent A, liquid HI93735B-0 buffer and HI93735C-0 fixing-reagent powder packets. Test capacity describes complete determinations; it does not specify retail bottle counts or bottle fill volumes. The photometer and sample-handling equipment are separate requirements.

Prepare the cuvette before zeroing

For HI97735, select Total Hardness HR. Add 0.5 mL of unreacted sample and 0.5 mL of liquid HI93735IND-0 to the cuvette. Use a plastic pipette to fill to the 10 mL mark with HI93735A-HR (the required-reagents table lists 9 mL). Add two drops of HI93735B-0, replace the plastic stopper and cap, and invert five times. Seat the cap notch securely in the holder groove, then press Zero. Do not zero with untreated sample.

Add the fixing reagent only after zeroing

Remove the cuvette, add the contents of one HI93735C-0 packet, replace the plastic stopper and cap, and shake gently for 20 seconds. Reinsert with the notch correctly seated and press Read. The result is displayed in mg/L as CaCO₃. This is a concise HI97735 workflow reminder, not a substitute for its instruction manual or the procedure for another instrument.

Set up a repeatable measurement

Have a compatible photometer, suitable cuvette with plastic stopper and cap, accurate 0.5 mL sample and indicator measurement equipment, a plastic filling pipette, scissors and a lint-free wipe ready. Keep the optical surfaces clean and follow the instrument’s cuvette handling instructions. The manual identifies excessive heavy metals as a possible interference; investigate an unusual sample matrix rather than assuming an out-of-range result is valid.

Compatibility and range selection

HI97735 section 8.3 documents this exact HI93735-02 set and procedure. The approved model evidence also lists HI93735-02 for HI83300 and HI83399 total-hardness HR methods; use each instrument’s own method instructions. This page is a single HR reagent set, not the HI93735-0 mixed-range assortment and not the HI93720 calcium-hardness or HI937521 calcium-ion chemistry.

Handle every component as directed by its SDS

Read all four current US component safety data sheets before use. The indicator can irritate skin and eyes. Buffer B is combustible, irritates skin and eyes, and is harmful to aquatic life with long-lasting effects. Fixing reagent C is harmful if swallowed or inhaled, causes serious eye damage and may cause organ damage through prolonged or repeated exposure. Wear the protective equipment required by the SDS, avoid dust and splashes, keep buffer away from ignition sources, and follow local disposal requirements. The safety documents are component-specific; they are not an air-shipping authorization.

Keep consumable planning separate from stock promises

Plan replenishment by complete tests while allowing for your quality-control use and laboratory procedures. Use the expiry and storage instructions supplied with the actual lot; dates visible in the product photograph are not current-stock expiry. No bottle quantity, shipping weight, dispatch date or carrier permission is inferred from the photograph or per-test doses.

Frequently Asked Questions

What does this reagent pack measure?

HI93735-02 measures total calcium plus magnesium hardness over 400–750 mg/L as CaCO₃. Results are expressed as calcium carbonate equivalent, not as calcium ions or total dissolved solids.

Is this just another pack size of the other hardness ranges?

No. HR is a distinct range-specific chemistry using HI93735A-HR. The other total-hardness ranges use their own Reagent A and instrument programs. Choose the method that covers the expected sample concentration; do not swap Reagent A across ranges.

How many tests are supplied, and are bottle volumes specified?

The manufacturer specifies sufficient reagents for 100 complete tests. Retail bottle counts and fill volumes are not established here. Per-test quantities describe the analytical method, not the number or size of containers supplied.

Is HI93735IND-0 a powder or a liquid?

In the current HI97735 method, HI93735IND-0 is a liquid indicator dosed at 0.5 mL per test. Reagent A and buffer B are also liquids; HI93735C-0 is the powder packet added after zeroing. Do not follow an old powder-indicator assumption.

When do I zero the HI97735?

Zero after combining 0.5 mL sample, 0.5 mL indicator, HI93735A-HR to the 10 mL mark and two drops of buffer B, then inverting five times. Only after zeroing should you add one C packet, gently shake for 20 seconds and read. Follow the full instrument manual for handling and operation.

Which instruments can use this exact set?

The HI97735 manual lists HI93735-02 for its Total Hardness HR method. The approved HI83300 and HI83399 method evidence also lists the set. Verify the exact method on your instrument and follow its own instructions; a reagent listing is not universal photometer compatibility.

What else is needed and what can interfere?

A compatible photometer, suitable cuvette, stopper and cap, accurate small-volume measurement equipment, plastic filling pipette, scissors and a clean optical wipe are needed. Excessive heavy metals can interfere. These reagents do not turn a calcium-only method or a dissolved-solids meter into a total-hardness measurement.

What safety, transport and expiry information should I use?

Use the four linked US component SDS and the labels on your actual lot. Indicator and buffer cause irritation; buffer is combustible; fixing reagent C has ingestion, inhalation and serious-eye-damage hazards. Shipping classification and carrier acceptance require appropriate review; no air permission or blanket non-hazardous claim is made. Photograph dates are illustrative, not current-stock expiry.

    Product Specifications

    SpecificationDetail
    Manufacturer catalog numberHI93735-02
    ParameterTotal calcium + magnesium hardness
    Measurement range400–750 mg/L as CaCO₃
    Pack capacity100 complete tests
    MethodAdaptation of EPA Recommended Method 130.1
    IndicatorHI93735IND-0 liquid — 0.5 mL per test
    Range reagentHI93735A-HR liquid — fill prepared sample to 10 mL; manual reagent quantity 9 mL
    BufferHI93735B-0 liquid — 2 drops per test
    Fixing reagentHI93735C-0 powder — 1 packet after zeroing
    Sample volume0.5 mL unreacted sample
    Zero preparationSample + indicator + range-specific A + B; invert 5 times
    Read preparationAfter zero: add C packet; shake gently 20 seconds; read
    Primary method referenceHI97735 instruction manual, MAN97735 05/23
    Interference notedExcessive amounts of heavy metals
    Instrument and handling equipmentSeparate requirements; follow instrument instructions

    Ordering Information

    Catalog numberReagent pack
    HI93735-02One range-specific reagent pack for 100 complete total-hardness tests

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.