Hanna HI93718 Iodine Reagents, 100/300 Tests Photometer Reagents Hanna Instruments
Hanna HI93718 Iodine Reagents, 100/300 Tests Photometer Reagents Hanna Instruments

Hanna HI93718 Iodine Reagents, 100/300 Tests

$40.69

    Keep iodine residual testing on the right chemistry. Keep HI97718 water-sample testing supplied with the complete matched iodine reagent set.

    • HI93718-01: 100 tests; HI93718-03: 300 tests
    • HI97718: 0.0 to 12.5 mg/L as I₂
    • Reagents only; meter, cuvettes and CAL Check standards separate

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

HANNA PHOTOMETER REAGENTS · HI93718

Keep iodine residual testing on the right chemistry.

Refill your HI97718 iodine workflow with pre-measured DPD powder packets. The 100- and 300-test packs deliver the same iodine method, giving you a choice of capacity rather than a change in range.

Official Hanna HI93718 reagent set reference photo
Official Hanna iodine reagent-pack reference photo. Printed lot and expiry markings are illustrative, not supplied-stock dates.

Match the method, not just the element name

HI97718: 0.0 to 12.5 mg/L as I₂. DPD chemistry develops a pink tint in iodine-containing samples. HI97718 reports 0.0 to 12.5 mg/L as I₂. These are iodine reagents, not iodide analysis or a selective replacement for chlorine or bromine chemistry.

What the selected pack supplies

The selected pack supplies HI93718-0 iodine powder reagent for 100 or 300 tests; one packet is used per determination. Photometer, cuvettes and validation standards are separate.

Where this method fits

Useful for an established water-testing program that specifies iodine as I₂. Check other oxidants and the sample’s hardness, alkalinity and acidity before interpreting a result; this is not a guarantee of iodine selectivity in mixed-disinfectant water.

The HI97718 workflow at a glance

Fill a clean cuvette with 10 mL of unreacted sample. Stopper and cap, align the notch securely in the holder groove and zero the HI97718. Remove the cuvette, add one HI93718-0 packet and shake gently for about 20 seconds to dissolve most of the reagent. Reinsert with the same alignment and use the 2-minute 30-second Read countdown before recording iodine as I₂.

Check the sample matrix

Bromine, chlorine, oxidized chromium and manganese, and ozone may interfere. Hardness above 500 mg/L as CaCO₃ calls for approximately 2 minutes of shaking after reagent addition. Alkalinity above 250 mg/L or acidity above 150 mg/L as CaCO₃ can give partial or fading color; follow the manual’s neutralization guidance with diluted HCl or NaOH.

Choose a pack around your workload

HI93718-01 supplies 100 tests; HI93718-03 supplies 300 tests. The larger pack supplies three times the determinations, not a different measuring range. One order quantity means one complete selected pack. Choose by testing frequency and the lot/expiry markings on supplied stock.

What to have beside the reagent set

Supply the compatible photometer, cuvettes with stoppers and caps, and the measuring/dispensing accessories required by the method separately. CAL Check standards are separate instrument-verification materials, not replacements for sample reagents.

Handling before you begin

The US SDS identifies inhalation and repeated-exposure hazards. Avoid breathing powder, use the specified protection and follow storage and disposal instructions. Absence of a Dangerous Goods notice on the retail page is not a guarantee of unrestricted transport everywhere.

Use the linked HI97718 instrument manual as the method reference for the complete procedure, precautions and instrument operation. This is not a separate reagent instruction manual.

Frequently Asked Questions

Should I choose 100 or 300 tests?

HI93718-01 supplies 100 tests; HI93718-03 supplies 300 tests. Both are complete reagent sets for the same method. Choose by expected workload and marked expiry dates, not by a different analytical range.

Does this measure iodine or iodide?

The HI97718 DPD method reports iodine as I₂, not iodide. Its range is 0.0 to 12.5 mg/L as I₂. Confirm that this is the parameter specified by your water-testing program.

When do I zero the photometer?

Zero the HI97718 using 10 mL of unreacted sample before adding the powder. Then add one HI93718-0 packet, shake gently for about 20 seconds and use the 2-minute 30-second Read countdown.

Can chlorine or bromine affect the iodine reading?

Yes. Chlorine, bromine, ozone and oxidized forms of chromium and manganese are listed interferences. Do not assume selective iodine measurement in a mixed-oxidant sample.

What if the sample is hard or highly alkaline?

Follow the manual: hardness above 500 mg/L as CaCO₃ calls for about 2 minutes of shaking after reagent addition. Alkalinity above 250 mg/L or acidity above 150 mg/L as CaCO₃ requires the specified neutralization guidance to prevent partial or fading color.

Which photometers are documented for HI93718?

Both packs are documented for HI97718. The procedure and range on this page use HI97718 as the primary reference; follow the exact instrument method when using another model.

Which sample conditions should I check first?

Bromine, chlorine, oxidized chromium and manganese, and ozone may interfere. Hardness above 500 mg/L as CaCO₃ calls for approximately 2 minutes of shaking after reagent addition. Alkalinity above 250 mg/L or acidity above 150 mg/L as CaCO₃ can give partial or fading color; follow the manual’s neutralization guidance with diluted HCl or NaOH.

Are the instrument, cuvettes and CAL Check standards included?

No. These are reagent-only packs. Provide the photometer, cuvettes with stoppers and caps, and the method-required sampling and dispensing accessories separately. CAL Check standards are separate instrument-validation materials, not test reagents.

    Product Specifications

    SpecificationDetail
    ParameterIodine
    Reagent formatPre-measured HI93718-0 iodine powder packets
    MethodAdaptation of Standard Methods for the Examination of Water and Wastewater, 18th Edition, DPD Method
    Primary instrumentHI97718
    Range and reporting basis0.0 to 12.5 mg/L as I₂
    Documented instrumentsHI97718
    Reagent dose1 packet HI93718-0 per determination
    Sample and zero preparation10 mL unreacted sample for zeroing and subsequent reaction
    Timing on HI97718Shake gently about 20 seconds; use 2-minute 30-second countdown
    MatrixBromine, chlorine, oxidized chromium and manganese, and ozone may interfere. Hardness above 500 mg/L as CaCO₃ calls for approximately 2 minutes of shaking after reagent addition. Alkalinity above 250 mg/L or acidity above 150 mg/L as CaCO₃ can give partial or fading color; follow the manual’s neutralization guidance with diluted HCl or NaOH.
    Pack contentsThe selected pack supplies HI93718-0 iodine powder reagent for 100 or 300 tests; one packet is used per determination. Photometer, cuvettes and validation standards are separate.
    Separate requirementsCompatible meter, cuvettes, stoppers, caps, method-required sample/dispensing accessories and CAL Check standards

    Ordering Information

    Catalog numberComplete reagent pack
    HI93718-01100 tests — complete iodine reagent set
    HI93718-03300 tests — complete iodine reagent set

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.