Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Hanna HI93701-F Free Chlorine Liquid Reagents — 300 Tests Default Title Photometer Reagents Hanna Instruments
Hanna HI93701-F Free Chlorine Liquid Reagents — 300 Tests Default Title Photometer Reagents Hanna Instruments

Hanna HI93701-F Free Chlorine Liquid Reagents — 300 Tests

$43.99

    Free chlorine, ready for your liquid method. Ready-made liquid DPD reagents for nominally 300 free-chlorine tests. Match your exact meter and liquid method.

    • Free chlorine only; A-F/B-F system, no C-T
    • HI971044 v1.02+ / HI97104 v1.04+ liquid methods verified
    • Distinct from HI93701-01/-03 powder refills

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

Free chlorine, ready for your liquid method

Keep routine free-chlorine testing simple with Hanna HI93701-F ready-made liquid DPD reagents. This factory reagent set provides a nominal 300 free-chlorine tests, with bottle lot numbers and expiration dates for traceability. Choose it when you need free chlorine—not a total-chlorine refill—and your exact meter supports the liquid method.

Hanna HI93701-F liquid free chlorine reagent set A-F and B-F
Manufacturer identification photo. Historical label dates are illustrative, not the expiry of the supplied lot; the image is not a current bottle-count or volume declaration.

Match the liquid method before you refill

HI971044 software v1.02 and higher and HI97104 software v1.04 and higher have individually verified liquid-chlorine procedures in their current manuals. Select Chlorine (Liquid), not the powder method. The separate free-chlorine procedure uses a 10 mL sample and a manufacturer-recommended 1-minute reaction; follow the meter tutorial and your approved timer settings.

The manufacturer describes an expected free-chlorine range of 0.00–5.00 mg/L (ppm). That range does not make this a universal photometer reagent: confirm the exact model, firmware and selected method. HI83300 also has a directly verified free-chlorine liquid procedure; use its own instructions. Hanna Germany’s broad regional advisory advises against these liquids on current HI97xxx/HI833xx instruments, conflicting with the current exact-model US-linked manuals. Our claims follow the verified model, software and liquid method—not worldwide series compatibility; check the manual for your instrument and market.

Buy the free-only refill—or plan paired readings correctly

HI93701-F supplies the free-chlorine A-F/B-F reagent system. It does not include HI93701C-T for total chlorine. If your workflow needs both free and total chlorine, the exact HI93701-T liquid set can already deliver sequential free then total readings on HI971044 v1.02+ or HI97104 v1.04+: read free chlorine after 1 minute, then add C-T to the same cuvette and allow 1 additional minute. You do not automatically need both retail sets. The manuals permit A-T/A-F and B-T/B-F interchange only within this named method; the retail kits are not aliases.

Liquid is a method choice, not a powder-pack replacement

HI93701-F is distinct from HI93701-01 and HI93701-03 powder reagents. Match the reagent form to the program on your meter rather than substituting drops for a powder packet. Do not assume support across every HI97-series meter or every chlorine Checker; use the exact-model manual.

What you receive—and what your bench still needs

Order one factory HI93701-F reagent set, with nominal capacity for 300 free-chlorine tests and component identities HI93701A-F and HI93701B-F. A compatible photometer, suitable clean cuvettes, sample and normal testing accessories are separate. This is not a meter, CAL Check standard, or complete total-chlorine kit. Current source text does not establish a factory bottle count or individual bottle volumes, so neither is promised here.

Make the nominal capacity useful in practice

The 300-test rating is the manufacturer’s set capacity, also listed in MAN971044 11/25; it is not derived from the photograph or a guessed bottle size. Repeats, handling loss and expiry can reduce usable tests. For the primary HI971044 liquid method, observe the manual’s sample-below-27 °C guidance and reaction times referenced at 25 °C; do not transfer its settings to another instrument without checking.

Care for the reagents between testing rounds

Keep A-F and B-F in their original, clearly labelled, tightly sealed containers in a dry, ventilated place; avoid overheating and incompatible materials. Protect A-F from moisture and light. Both component SDS identify corrosive hazards: use the specified eye/skin protection and handling and disposal controls. Review the linked US component SDS against the labels supplied with your lot. No shelf-life or stock-lot expiry is guaranteed by the photograph. Hanna US classifies this HI93701-F kit as Dangerous Goods for ground-only shipping; the shared policy’s generic expedited options do not establish eligibility for this kit. Confirm destination and service before ordering.

Frequently Asked Questions

What exactly is HI93701-F?

It is Hanna’s liquid free-chlorine reagent set, nominally rated for 300 tests. Its reagent identities are HI93701A-F and HI93701B-F. The rating is for the set, not 300 tests per bottle.

Will this measure total chlorine too?

Not on its own: the F set does not contain total-chlorine component HI93701C-T. For paired free/total readings, check whether the HI93701-T set and your exact instrument’s sequential liquid procedure meet your needs before buying additional kits.

Do paired free and total readings always need two kits or fresh separate samples?

No. HI971044 v1.02+ and HI97104 v1.04+ document a sequential HI93701-T liquid method: a free reading after 1 minute, then C-T added to the same reacted cuvette for a total reading after 1 additional minute. Separate fresh-sample procedures are also provided. Follow the exact program; do not generalize this to powder methods or other meters.

Can I use it in place of HI93701-01 or HI93701-03 powder?

They are different reagent formats, not interchangeable retail refills. Use HI93701-F only with a verified liquid procedure and the correct method selection. Do not use powder-packet dosing or shaking instructions for this set.

Which model and software should I check?

The current manuals individually verify HI971044 v1.02+ and HI97104 v1.04+ liquid methods; HI83300 has its own verified liquid free-chlorine procedure. Read your model and firmware information, then follow that model’s manual. A similar model name or the HI97 prefix alone does not establish compatibility.

What is included, and are bottle quantities or volumes guaranteed?

One factory HI93701-F reagent set is offered, with the A-F/B-F reagent identities and nominal 300-test capacity. A meter, cuvettes, sample, CAL Check standards and C-T are not included. Current source text does not specify factory bottle quantities or individual volumes; the illustration is not a packing list.

How long is the liquid free-chlorine reaction?

The primary HI971044 separate free-liquid procedure uses a 10 mL sample and a manufacturer-recommended 1-minute reaction. Tutorial mode follows recommended times; SOP-adjusted timers can differ. Timing, sample temperature and handling belong to the exact instrument procedure—use the linked PDF for full dosing and steps.

How should I store it, and does the old photograph show the lot I will receive?

Store in original, sealed, labelled containers in a dry, ventilated place, away from heat and incompatible materials; protect A-F from light and moisture. Follow each component’s SDS. Historical dates in the manufacturer photograph are illustrative, not a statement that current sale stock is expired or a promise of the supplied lot’s expiry. Check the received labels.

    Product Specifications

    SpecificationDetail
    Manufacturer catalog numberHI93701-F
    Measured parameter / reagent formFree chlorine / liquid DPD reagents
    Manufacturer expected sample range0.00–5.00 mg/L (ppm) free chlorine; exact instrument procedure governs
    Nominal set capacity300 free-chlorine tests; repeats, loss and expiry can reduce usable yield
    Reagent component identitiesHI93701A-F and HI93701B-F
    Total-chlorine componentHI93701C-T not included
    Verified portable liquid-method scopeHI971044 v1.02+; HI97104 v1.04+; select Chlorine (Liquid)
    Verified benchtop liquid-method scopeHI83300; follow its own free-chlorine liquid procedure
    Primary method sample / reactionHI971044: 10 mL / recommended 1 minute for separate free chlorine
    Temperature contextHI971044: sample below 27 °C; reaction times referenced at 25 °C
    Factory bottle count / individual volumesNot specified in current source text; no quantities inferred from photograph
    Required separatelyCompatible meter, suitable cuvettes, sample and testing accessories

    Ordering Information

    SpecificationDetail
    HI93701-FOne factory liquid free-chlorine reagent set; 300 nominal tests; A-F/B-F components; meter and cuvettes separate

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.