Hanna HI784-25 Marine Ammonia Reagents, 25 Tests Default Title Photometer Reagents Hanna Instruments
Hanna HI784-25 Marine Ammonia Reagents, 25 Tests Default Title Photometer Reagents Hanna Instruments

Hanna HI784-25 Marine Ammonia Reagents, 25 Tests

$31.89

    Follow marine ammonia trends with the right refill.

    • HI784 Checker: 0.00–2.50 ppm combined ammonia/ammonium reported as NH₃ mass
    • Documented HI83399 Marine Ammonia method also supported; current liquid A and powder B/C formulation
    • 25-test capacity for ongoing saltwater monitoring; no heated digestion

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

Follow marine ammonia trends with the right refill

Keep routine saltwater ammonia checks going with the three-reagent refill for HI784 and the documented HI83399 Marine Ammonia method. The method measures ammonia and ammonium together and reports the result as NH₃ mass—useful for monitoring changes, not a direct free-ammonia toxicity reading.

Hanna HI784-25 manufacturer reagent refill photograph
Manufacturer photograph of the marine reagent refill; packaging shown is representative.

Select the right method

Choose for marine samples and a 0.00–2.50 ppm result reported as NH₃. The combined NH₃/NH₄⁺ measurement is not TAN-N or NH₃-N, and is not a measurement of only free, unionized NH₃. No numerical salinity operating interval is asserted.

Three matched reagents for 25 tests

HI784-25 replenishes HI784A-0, HI784B-0 and HI784C-0 for 25 marine ammonia tests. The current formulation uses liquid A with powder B and C. Match your refill to the current instrument instructions rather than using obsolete drop-count directions.

Choose the current liquid-and-powder workflow

The current HI784 Checker method uses a measured 1 mL dose of liquid A with powder B and C; the documented HI83399 Marine Ammonia method also uses this formulation. Have accurate, clean measuring tools ready and follow the full PDF for your instrument. Do not combine the current reagents with the old 18-drop/12-drop method.

Interpret the result on the correct mass basis

The blue-green salicylate reaction measures ammonia and ammonium together. HI784 Checker and the documented HI83399 Marine Ammonia method report the combined result as NH₃ mass—not nitrogen mass (TAN-N or NH₃-N). This is not a direct free, unionized NH₃ toxicity reading: estimating that portion needs separate pH and temperature information and an appropriate marine equilibrium interpretation.

Fresh samples make trends more useful

For HI784 Checker and the documented HI83399 Marine Ammonia method, prepare the sample immediately after collection: ammonia can dissipate during storage and bias results low. Keep the prepared cuvette (sample plus reagents) at 18–29 °C. Complete powder dissolution, clear cuvette surfaces and bubble-free readings support consistent repeat checks.

Prepare your existing setup for the next test

Have the HI784 Checker or HI83399 with its named Marine Ammonia method, a clean cuvette and cap, 1 mL syringe with tip, transfer pipette, scissors and lint-free wiping material ready separately. This is a reagent refill, not a meter or complete accessory kit; the documented method needs no heated digestion.

Practical handling

Wear the protective equipment specified in the component SDS, avoid contact with reagents and dispose of used solutions according to the SDS and local requirements. Check the supplied lot label and component SDS before use.

Frequently Asked Questions

What buying need does HI784-25 cover?

It replenishes the matched marine ammonia chemistry for an HI784 already owned or the documented HI83399 Marine Ammonia method. Choose it for routine monitoring of combined ammonia/ammonium in marine water, not as a generic freshwater reagent replacement.

Does the 2.50 ppm range mean TAN-N?

No. The 0.00–2.50 ppm scale is reported as NH₃ mass, although the method measures NH₃ and NH₄⁺ together. TAN-N and ammonia-nitrogen use nitrogen mass and cannot take the same numerical label without conversion.

Is this a direct measurement of toxic free ammonia?

No. It measures combined ammonia/ammonium, not only unionized NH₃. Estimating the unionized fraction needs separate pH and temperature information and an appropriate marine equilibrium interpretation; the result alone is not a toxicity verdict.

Should I use the old 18-drop and 12-drop directions?

No. The current 07/25 HI784 method uses 1 mL liquid A and powder packets B and C. Follow the current instrument manual and the instructions matching your actual reagents; do not mix old and new physical reagent versions.

What is the current timing sequence?

After A and B, add sample to 10 mL, dissolve gently for 60–90 seconds, stand 30 seconds and zero. After adding C, dissolve for 30 seconds and develop for 15 minutes. The HI784 manual allows 10 minutes only below 1.00 ppm; do not apply that exception universally.

Can I collect the sample now and test it later?

The instructions call for preparation immediately after collection. Ammonia can dissipate from stored samples and produce low measurements. Keep the prepared cuvette within 18–29 °C and follow the full method.

Do I need a heater or a specific salinity in ppt?

No heated digestion is specified. The documented application is marine water, but no numerical ppt or PSU operating interval is established here. Do not infer suitability for an unusual brine from the marine label alone.

How should I plan for capacity and reusable tools?

Hanna states 25 tests; repeats and quality-control checks consume that capacity too. Have the meter, clean cuvette and cap, accurate 1 mL syringe with tip and transfer pipette ready separately. The capacity rating does not specify physical bottle or packet counts. Use the supplied lot label for expiry information.

    Product Specifications

    SpecificationDetail
    Manufacturer catalog numberHI784-25
    MatrixMarine water / saltwater aquarium applications
    HI784 range and reporting basis0.00–2.50 ppm; combined NH₃/NH₄⁺ reported as NH₃ mass
    HI83399 range and reporting basis0.00–2.50 ppm as NH₃; combined ammonia/ammonium, §9.4
    Resolution0.01 ppm on the documented methods
    Accuracy±0.05 ppm ±5% of reading at 25 °C
    Prepared cuvette temperature18–29 °C, sample plus reagents
    Per-test additions1 mL HI784A-0; 1 packet HI784B-0; sample to 10 mL; 1 packet HI784C-0
    Development15 minutes; HI784 manual allows 10 minutes only below 1.00 ppm
    ChemistrySalicylate method; no heated digestion
    Stated capacity25 tests; repeats and QC consume reagents
    Documented instrumentsHI784 Checker and HI83399 named marine method

    Ordering Information

    SpecificationDetail
    HI784-25One reagent set for 25 nominal tests

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.