Hanna HI781-25 Marine Nitrate Low Range Reagents — 25 Tests Default Title Photometer Reagents Hanna Instruments
Hanna HI781-25 Marine Nitrate Low Range Reagents — 25 Tests Default Title Photometer Reagents Hanna Instruments

Hanna HI781-25 Marine Nitrate Low Range Reagents — 25 Tests

$27.49

    Resolve low marine nitrate without switching to a high-range refill. Keep low-range marine nitrate monitoring supplied with the three-reagent HI781-25 refill for 25 tests. Its zinc-reduction color reaction is intended for seawater and low nitrate levels, with a filtration step that is part of the measurement—not an optional cleanup.

    • 0.00–5.00 ppm as NO3− direct; samples above 5 up to 50 ppm use the exact approved 1:10 dilution
    • 25-test reagent refill; match your exact instrument method
    • Check separate cuvettes, helpers and workflow accessories before ordering

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

Resolve low marine nitrate without switching to a high-range refill

Choose HI781-25 to keep low-level seawater nitrate monitoring supplied with 25 tests of the matched three-reagent formulation. It suits an existing HI781 Checker or HI83399 Marine Nitrate Low Range setup when you want low-range readings and can include the required filtration stage.

Hanna HI781-25 manufacturer reagent photograph
Manufacturer component illustration; use the supplied lot label, not photographed dates or volumes.

Match the matrix, method and reporting basis

0.00–5.00 ppm as NO3− direct; samples above 5 up to 50 ppm use the exact approved 1:10 dilution

Match this refill to the HI781 Checker or HI83399 Marine Nitrate Low Range method. It is not HI782-25 high-range chemistry or a freshwater nitrate substitute. The direct range is as nitrate (NO3−), not nitrogen; HI83399’s chemical-form display conversion does not change that reporting distinction.

What one refill supplies

One HI781-25 refill provides reagent capacity for 25 tests using liquid HI781A-0 and powders HI781B-0 and HI781C-0. It is not an instrument starter kit. Do not assume filters, holder, syringes or other method tools are included; check and replenish your existing setup separately.

Have the complete testing workflow ready

Filtration is mandatory, so have the HI740271 filter holder, dry HI740228 filter discs, HI740270 10 mL Luer-lock syringe, HI740226 5 mL syringe/tip, mixing vial, HI740272 blunt needle and model-appropriate cuvette/cap available. Keep scissors and a lint-free wipe ready. Approved dilution also needs an accurate 1 mL syringe and nitrate/nitrite-free artificial seawater.

Plan for the method, not just the reagents

Allow time for the complete reduction, filtration and timed color-development stages—not just a quick reagent addition. Follow all preparation, mixing, filtration and timing conditions in the HI781 Checker manual or the HI83399 Marine Nitrate LR method, as appropriate. Shared reagent chemistry does not make the two instruments’ operating instructions interchangeable.

Above 5 ppm? Check the approved dilution limits

For 5–50 ppm nitrate samples only, the approved 1:10 dilution can extend testing beyond the direct 0.00–5.00 ppm range. It requires nitrate/nitrite-free artificial seawater, the full model-specific preparation and timed method, and a ×10 result correction. Dilution reduces accuracy; it is not an unrestricted 0–50 ppm range. Follow the linked model manual for every dilution and measurement condition.

Handling and shipment checks

Nitrite and copper interfere. Review all three component SDS and the supplied labels for PPE, storage and waste handling. Confirm destination and carrier eligibility before ordering: component transport provisions do not establish a whole-refill shipping exemption, and Hanna specifies ground-only shipping for Dangerous Goods.

Frequently Asked Questions

When should I choose HI781-25 rather than HI782-25?

Choose HI781-25 for the documented marine low-range method, 0.00–5.00 ppm as nitrate. HI782-25 is high-range chemistry and is not a substitute in an HI781 method. Match the reagent code to the exact program, not just the word nitrate.

Is the range reported as nitrate or nitrate-nitrogen?

The direct 0.00–5.00 ppm range is as NO3−, not as N. HI83399 can display nitrate-nitrogen through its chemical-form function. Numerically equal NO3− and NO3−–N results mean different concentrations; do not relabel a nitrate reading as nitrogen.

Which instruments have a verified method?

The current HI83399 manual lists HI781-25 for Marine Nitrate Low Range. The HI781 Checker manual also specifies this refill. Other benchtop models are not added merely because they measure nitrate, and this page does not create or imply a separate Checker instrument listing.

What do the three reagent components do?

The procedure adds HI781A-0 and HI781B-0 before filtration, then zeroes the filtered preparation and adds HI781C-0 for final color development. The prescribed per-test doses are 4 mL A and one packet each of B and C. These method quantities do not establish the supplied bottle fill or full physical pack contents.

Are the filters, holder and syringes in the refill?

They are required for the procedure but are not established as included with HI781-25. The HI781 instrument starter-kit contents are not the reagent refill packing list. Check your reusable holder, 10 mL Luer-lock syringe, 5 mL syringe/tip, mixing vial, blunt needle and cuvette; replenish the dry filter discs separately as needed.

Why must the sample be filtered?

Filtration is a prescribed stage after adding reagents A and B and before zeroing. Use a dry filter disc and holder, apply constant light pressure and allow about 30 seconds. Excess pressure can tear the filter; a wet assembly or omitted filtration is not the documented method.

Can I measure samples above 5 ppm?

Only with the approved 1:10 preparation for 5–50 ppm samples: dilute 1 mL sample to 10 mL with nitrate/nitrite-free artificial seawater, mix, use 7 mL of that preparation and complete the normal method. Multiply by 10. The HI781 manual specifies degraded diluted accuracy of ±2.5 ppm ±5% of calculated reading; measure volumes carefully.

Which timing, interferences and safety checks matter?

On HI781, shake the A/B preparation for one minute, filter, zero, add C and shake for two minutes, then allow the eight-minute color-development time. Nitrite and copper interfere. Consult all three component SDS and the full method; the transport status of one component is not a whole-kit shipping guarantee.

    Product Specifications

    SpecificationDetail
    Catalog numberHI781-25
    MethodZinc reduction; pink/violet color development
    Direct range / basis0.00–5.00 ppm as NO3−
    Approved extended sample range5–50 ppm as NO3− only by the exact 1:10 marine dilution; multiply by 10
    HI781 resolution / direct accuracy0.01 ppm; ±0.25 ppm ±2% of reading at 25 °C
    HI781 diluted accuracy±2.5 ppm ±5% of calculated reading
    MatrixSeawater / marine samples
    Per-test reagent doseHI781A-0: 4 mL; HI781B-0: 1 packet; HI781C-0: 1 packet
    FiltrationRequired; dry filter disc and holder, light constant pressure
    Known interferencesNitrite and copper
    Pack capacity25 tests; no accessory or bottle-volume inference

    Ordering Information

    SpecificationDetail
    HI781-25Marine Nitrate Low Range reagent refill — 25 tests; instrument and separate workflow requirements not included unless expressly stated above

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.