Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Heathrow Scientific Refractive Index Refractometer | 43055 Default Title Heathrow Scientific
Heathrow Scientific Refractive Index Refractometer | 43055 Heathrow Scientific
Heathrow Scientific Refractive Index Refractometer | 43055 Default Title Heathrow Scientific
Heathrow Scientific Refractive Index Refractometer | 43055 Heathrow Scientific

Heathrow Scientific Refractive Index Refractometer | 43055

$142.00

    Read refractive index from 1.435 to 1.520 nD with the compact NDX-2 optical handheld refractometer.

    • 0.001 nD resolution and ±0.001 nD stated accuracy
    • Rubber grip, metal prism housing and non-roll stand
    • One instrument with case, transfer pipet and manual

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Choose refractive index—not an application conversion

Read refractive index from 1.435 to 1.520 nD with the compact NDX-2 optical handheld refractometer.

Heathrow Scientific Refractive Index Refractometer | 43055 — Choose refractive index—not an application conversion
Manufacturer product view. Illustrated supplies show an application; refer to the stated order unit for the item supplied.

Choose refractive index—not an application conversion

The NDX-2 presents a direct refractive-index scale for samples that fall within 1.435–1.520 nD. This is a useful distinction when your method calls for nD rather than a Brix, salinity or coolant conversion. Compare your expected result range with both endpoints before ordering; the model does not extend down to the refractive index of pure water.

An optical instrument with controlled handling

The high-contrast scale, optical-glass prism and all-metal prism housing support a clear boundary-line reading. The rubber grip limits direct hand heat reaching the body, while the non-roll stand helps keep the instrument in place on a flat bench. Leave time for sample and prism temperatures to settle rather than relying on the grip alone.

Heathrow Scientific Refractive Index Refractometer | 43055 — An optical instrument with controlled handling
Manufacturer product view. Illustrated supplies show an application; refer to the stated order unit for the item supplied.

Temperature correction matters for this model

NDX-2 does not have automatic temperature compensation. Its manual calls for calibration at the start of the day and when ambient temperature changes; it also explains correction for water-based solutions and oils. Use the coefficient appropriate to the sample and your method rather than transferring a correction from a different liquid.

Keep the method beside the instrument

The supplied vinyl case and transfer pipet make a compact bench or field set. The model-specific PDF below includes the calibration procedure and reference information. For broader-range digital nD work, compare a digital Brix/refractive-index model separately; display style and covered range are different selection questions.

Confirm the order unit

43055 — 1 Each.

Related choices for your workflow

Digital Brix and Refractive Index Refractometers

Compare digital nD instruments when you need a different range or a numerical display; verify the specific model before choosing.

Frequently Asked Questions

What is the NDX-2 range?

1.435–1.520 nD, with 0.001 nD resolution and ±0.001 nD stated accuracy.

Does it have automatic temperature compensation?

No. Use the calibration and temperature-correction guidance in the NDX-2 manual.

Can I use distilled water as the reading-range reference?

Pure-water nD is below this model’s range. Follow its specified calibration procedure and appropriate standard instead.

Can it measure oils?

The manual discusses both water-based solutions and oils, with different temperature-correction considerations.

What helps prevent it rolling on the bench?

The body includes a non-roll stand; place it on a stable, flat surface.

What is supplied?

One NDX-2 instrument, vinyl carrying case, transfer pipet and operation manual.

When should I check calibration?

The manual calls for calibration at the start of each day and when ambient temperature shifts.

    SpecificationDetail
    BrandHeathrow Scientific
    ModelVEE GEE NDX-2
    Catalog number43055
    Refractive-index range1.435–1.520 nD
    Resolution / accuracy0.001 / ±0.001 nD
    Automatic temperature compensationNo
    Dimensions140 × 40 × 40 mm
    Manufacturer warranty5 years; applicable terms and exclusions apply

    Ordering Information

    Cat. No.DescriptionPack
    43055Refractive Index Refractometer | 430551 Each

    Heathrow Scientific: Shipping, Returns & Manufacturer Support

    Blue Tiger Scientific is your reseller and point of contact for orders and returns purchased through our store.

    Shipping & Availability

    Shipping charges, available delivery methods and any delivery estimate are confirmed with your Blue Tiger Scientific order or quote. Contact Blue Tiger Scientific before ordering if you need a particular delivery date or special shipping arrangements. Supplier availability and carrier schedules can affect fulfillment; a delivery estimate is not a guaranteed arrival date.

    Returns Through Blue Tiger Scientific

    Start every return, exchange or order-related issue with Blue Tiger Scientific. Provide your order number, product catalog number, quantity and the reason for your request. For damage, missing items or an incorrect item, retain the packaging and include photographs where applicable.

    Do not send goods to Blue Tiger Scientific or Heathrow Scientific without return authorization and shipping instructions from Blue Tiger Scientific. We will coordinate any required manufacturer Return Goods Authorization (RGA). Return eligibility, any applicable charges and the approved shipping destination will be confirmed for your specific request before you ship. Keep the product, original packaging and supplied materials together while your request is reviewed.

    Manufacturer Warranty & Service

    Heathrow Scientific handles manufacturer warranty assessments, product service and other manufacturer-specific technical matters. Blue Tiger Scientific can help coordinate these requests and provide purchase documentation. If a return is required, arrange it through Blue Tiger Scientific before shipping.

    For this product, the manufacturer publishes a warranty period of 5 years; applicable terms and exclusions apply. Coverage, exclusions and service follow the applicable manufacturer terms; contact Blue Tiger Scientific to coordinate assessment. Retain proof of purchase.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat