    Firefly Lantern Extract is a dried extract of firefly light organs, the natural source of the luciferin-luciferase system that emits light in the presence of ATP. It is the classic reagent for detecting and measuring ATP by bioluminescence in sample extracts, enzyme reactions and biomass studies. Supplied as 100 mg of powder in one vial, soluble to 20 mg/mL in deionized water, and released against a bioluminescence test (Pass). Store at −20°C. Custom bulk amounts of this product are available upon request.

    Products are for in vitro research use only (RUO).

    Live Inquiry about this product via:

    Email: info@bluetigerscientific.com

    Text/SMS: (833) 928-4437 Mon–Fri, (8 am – 8 pm PST)

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

For purchasing details or COA/TDS availability, please request a quote.

Preparing Quote Cart. Your shopping cart stays unchanged.

Firefly Lantern Extract (Powder) – Catalog #B2022671

Firefly Lantern Extract (Catalog #B2022671) is a dried extract of firefly light organs ("lanterns"), supplied as one vial containing 100 mg of powder. Firefly lanterns are the natural source of the luciferin-luciferase system, the enzyme and substrate pair that emits light in the presence of ATP, magnesium and oxygen. Extracts of this type are the classic reagent for detecting and measuring ATP by bioluminescence. Each lot is checked with a bioluminescence test before release.

Catalog number: B2022671
Lot number: Batch Dependent
Expiration Date: Batch dependent
Amount: 1 vial, 100 mg
Form: Powder
Solubility: Soluble to 20 mg/mL in deionized water
Bioluminescence Test: Pass
Molecular Weight or Concentration: N/A (natural extract, not a single compound)
Applications: ATP detection and measurement by bioluminescence, luciferin-luciferase assays, ATP-based biomass estimation, bioluminescence teaching and method development
Storage: −20°C
Keywords: FLE, Firefly Lantern Extract, firefly luciferase, luciferin-luciferase reagent, ATP bioluminescence assay, ATP determination, bioluminescent extract
Grade: Biotechnology grade. All products are highly pure. All solutions are made with Type I ultrapure water (resistivity >18 MΩ-cm) and are filtered through 0.22 um.

Scientific Overview

The firefly lantern contains the enzyme luciferase and its substrate, D-luciferin. In the presence of magnesium ions and oxygen, luciferase uses ATP to oxidize luciferin and releases a photon of yellow-green light:

Luciferin + ATP + O₂ → Oxyluciferin + AMP + PPi + CO₂ + light (Mg²⁺, luciferase)

Because ATP is the limiting ingredient, the amount of light produced tracks the amount of ATP added. McElroy first showed in 1947 that ATP restores light emission in firefly lantern extracts, and Strehler and Totter turned that observation into a quantitative ATP assay in 1952. The method has since been used to measure ATP in cell and tissue extracts, enzyme reactions, and environmental samples such as seawater and sediments, where ATP serves as a marker of living biomass.

Typical uses of firefly lantern extract include:

  • Detecting and estimating ATP in sample extracts by bioluminescence
  • Following ATP-producing or ATP-consuming enzyme reactions
  • Estimating microbial biomass from ATP content
  • Teaching and demonstrating the luciferin-luciferase reaction
  • Method development where a classic, natural-source reagent is specified

Usage & Handling Guidance

Store the powder at −20°C. Reconstitute in deionized water at up to 20 mg/mL (5 mL dissolves the full 100 mg vial). The points below are general practice for natural firefly extracts from the published literature. They are not lot-specific instructions, so optimize for your own instrument and samples.

  • Keep it cold and dark: hold the reconstituted extract on ice and away from strong light, and use it the same day where possible.
  • Let the background settle: natural extracts carry some ATP of their own and glow briefly after reconstitution. Run a reagent blank and wait for the background to fall before measuring.
  • Always run ATP standards: this is a natural extract with no assigned activity value, so quantify against an ATP standard curve prepared in your own sample buffer.
  • Mind your buffer: the reaction needs magnesium. High salt and some anions reduce light output, so keep standards and samples in the same matrix.
  • Use clean plasticware: ATP from skin and microbes is a common source of false signal.

What You Get

  • 1 vial containing 100 mg of Firefly Lantern Extract powder
  • Water-soluble format (to 20 mg/mL in deionized water)
  • Lot release includes a pass/fail bioluminescence test
  • For in vitro research use only (RUO)

Why Researchers Choose It

  • Enzyme and substrate from the same natural source in one powder
  • The original reagent behind decades of published ATP bioluminescence methods
  • Simple water reconstitution, with no organic solvents required
  • A practical choice for teaching labs, method replication and qualitative ATP work
  • Direct support by email or text before and after you order

Frequently Asked Questions (FAQ)

  • Is Firefly Lantern Extract the same as, or similar to, ATP?
    No. ATP is a small nucleotide and is the molecule you measure. Firefly Lantern Extract is the detection reagent: it supplies luciferase and luciferin, which give off light when ATP is present. The extract does not replace ATP in an experiment, and you will need a separate ATP standard to build a calibration curve.
  • Does the extract contain any ATP of its own?
    Natural firefly extracts usually carry a small amount of residual ATP, which shows up as a background glow after reconstitution that fades with time. Running a reagent blank accounts for it.
  • How does a natural extract compare with purified or recombinant luciferase?
    A natural extract is a mixture, so it also contains other firefly enzymes. Published comparisons report that crude extracts have higher background light and can respond to nucleotides other than ATP, while purified luciferase is more specific. If your work needs strict ATP specificity or the lowest detection limits, a purified luciferase with added D-luciferin is the better fit. For classic protocols, teaching and qualitative or semi-quantitative ATP work, lantern extract is the traditional choice.
  • How do I reconstitute it?
    Add deionized water to the vial. The powder is soluble to 20 mg/mL, so 5 mL dissolves the full 100 mg.
  • What does "Bioluminescence Test: Pass" mean?
    The lot produced light when tested. It is a pass/fail check, not a measured activity. Luciferase activity, luciferin content and ATP sensitivity are not assigned for this product, so calibrate with your own ATP standards.
  • Is a Certificate of Analysis or Safety Data Sheet available?
    The manufacturer does not currently issue a lot-specific COA or an SDS for this product. The specifications on this page are the released specifications. Handle the powder with standard laboratory precautions (gloves, eye protection, avoid creating dust), as you would any biological extract of undefined composition. Contact us with any documentation questions before you order.
  • How should I store it?
    Store the powder at −20°C. Keep reconstituted extract on ice, protected from light, and use it promptly.
This product is for Research Use Only (RUO). It is not intended for diagnostic or therapeutic use in humans or animals.

References

  • McElroy WD. The energy source for bioluminescence in an isolated system. Proc Natl Acad Sci U S A. 1947;33(11):342-345. Reference
  • Strehler BL, Totter JR. Firefly luminescence in the study of energy transfer mechanisms. I. Substrate and enzyme determination. Arch Biochem Biophys. 1952;40(1):28-41. Reference
  • Holm-Hansen O, Booth CR. The measurement of adenosine triphosphate in the ocean and its ecological significance. Limnol Oceanogr. 1966;11(4):510-519. Reference
  • DeLuca M, McElroy WD. Purification and properties of firefly luciferase. Methods Enzymol. 1978;57:3-15. Reference
  • Karl DM. Cellular nucleotide measurements and applications in microbial ecology. Microbiol Rev. 1980;44(4):739-796. Reference
  • Lundin A. Use of firefly luciferase in ATP-related assays of biomass, enzymes, and metabolites. Methods Enzymol. 2000;305:346-370. Reference
  • Fraga H. Firefly luminescence: a historical perspective and recent developments. Photochem Photobiol Sci. 2008;7(2):146-158. Reference

    Terms & Conditions

    Blue Tiger Scientific is an independent third-party distributor of select products manufactured by Molecular Depot LLC. By purchasing from bluetigerscientific.com, you (“the Customer”) agree to the following terms, adapted from Molecular Depot’s original conditions:

    Product Use & Eligibility
    Products are for in vitro research use only (RUO). They are not intended for human or animal use, diagnosis, therapy, resale to consumers, or residential delivery. Sales are limited to verified business addresses.

    Payment Terms
    All purchases are prepaid and non-refundable once confirmed. Pricing is in USD and subject to change without notice.

    Purchase Orders
    Confirmed orders are final and may not be canceled or refunded unless authorized in writing.

    Limitation of Liability
    Blue Tiger Scientific and Molecular Depot LLC are not responsible for any damages resulting from product use or misuse.

    Waiver of Claims
    By ordering, you waive all claims arising from use of Molecular Depot products.

    Shipping & Handling
    Shipping is calculated at checkout. A minimum 27% handling fee applies to each order.

    Delivery Estimates All delivery timelines are estimates and not guaranteed. FedEx service levels are subject to operational delays, weather disruptions, and regional restrictions.

    FedEx Pickup Cutoff Orders submitted after the daily FedEx pickup window may not ship until the next available pickup day.

    Shipping Exceptions FedEx may impose restrictions or delays due to package size, weight, destination, or service availability. Blue Tiger Scientific is not liable for delays beyond our control.

    Weekend & Holiday Handling Orders placed on weekends or holidays will be processed on the next business day.

    Returns & Refunds
    Returns must be requested within 30 days through Blue Tiger Scientific. Refunds are only issued for shipping errors or verified defects, and processed within 45 business days if approved. Customers are responsible for return shipping costs unless otherwise stated. Refunds will exclude original shipping fees paid at checkout.

    Warranty Disclaimer
    All products are provided "as-is" with no warranties. Warranty issues are handled by the manufacturer.

    Safety Guidelines
    Always consult the product’s SDS. Products must not be ingested, inhaled, or come into contact with skin or eyes unless specified.

    Legal Use Compliance
    Products must not be used in violation of any law—local, state, federal, or international.

    Accuracy of Orders
    Customers are responsible for verifying all order details before submission.

    Changes or Cancellations
    All changes must be in writing and approved. Cancellations may result in fees for materials, labor, or third-party costs.

    Quality System (MD Levels)
    Molecular Depot’s MD-Quality System includes:

    MD 1000: Non-regulated use, no change notification

    MD 2000: Non-regulated use, limited change notification

    MD 3000: Regulated use, enhanced quality standards

    Delivery & Claims
    Orders may ship in parts. Claims for shortages or defects must be submitted within 2 days of receipt. Delivery dates are estimates only.

    Extended Payment Terms
    Payment is due within 30 days unless agreed otherwise. A 5% weekly penalty applies to late payments. Blue Tiger Scientific reserves discretion on payment application.

    Retention of Title
    Ownership remains with Blue Tiger Scientific or Molecular Depot LLC until payment is complete. Goods must be stored separately and labeled until paid in full.

    Intellectual Property
    No rights to manufacturing processes or IP are transferred. Blue Tiger Scientific is not liable for IP-related claims.

    Force Majeure
    Neither party is liable for delays or failures caused by uncontrollable events (e.g., weather, regulations, supply disruptions).

    Manufacturing Access
    Product purchase does not grant access to proprietary manufacturing documents or methods.

    Resale Prohibition
    Products cannot be resold without written approval from Molecular Depot LLC. Blue Tiger Scientific enforces this restriction.

    Governing Law
    Terms are governed by California and U.S. law. All disputes fall under U.S. jurisdiction.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.