Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera PION400 Portable pH/Ion Meter Platform (AI4326) Portable Ion Meter Apera Instruments
Apera PION400 Portable pH/Ion Meter Platform (AI4326) Portable Ion Meter Apera Instruments
Apera PION400 Portable pH/Ion Meter Platform (AI4326) Portable Ion Meter Apera Instruments
Apera PION400 Portable pH/Ion Meter Platform (AI4326) Portable Ion Meter Apera Instruments
Apera PION400 Portable pH/Ion Meter Platform (AI4326) Portable Ion Meter Apera Instruments
Apera PION400 Portable pH/Ion Meter Platform (AI4326) Portable Ion Meter Apera Instruments
Apera PION400 Portable pH/Ion Meter Platform (AI4326) Portable Ion Meter Apera Instruments
Apera PION400 Portable pH/Ion Meter Platform (AI4326) Portable Ion Meter Apera Instruments
Apera PION400 Portable pH/Ion Meter Platform (AI4326) Portable Ion Meter Apera Instruments
Apera PION400 Portable pH/Ion Meter Platform (AI4326) Portable Ion Meter Apera Instruments

Apera PION400 Portable pH/Ion Meter Platform (AI4326)

$390.00

    PION400 combines pH, mV, ion and temperature measurement in the portable 400-series platform. Choose the ion-selective electrode and calibration method for the ion you need to report; the meter platform is distinct from a named-ion complete kit.

    • Measurement modes: pH / mV / ion / temperature
    • pH range / accuracy: 0.00–14.00 / ±0.01 pH ±1 digit
    • Ion display range: 0.00–14.00 pX; electrode-specific concentration range

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / PION400 / AI4326

One portable platform.
Build the ion method around it.

PION400 combines pH, mV, ion and temperature measurement in the portable 400-series platform. Choose the ion-selective electrode and calibration method for the ion you need to report; the meter platform is distinct from a named-ion complete kit.

Manufacturer PION400 product reference.
Manufacturer PION400 product reference. Tap or click the image for a larger view.
Choose the right meter configurationClick or tap to compare your optionsCompare below — click or tap here to close
Apera IndSen family architecture reference; electrodes are selected separately.
Apera IndSen family architecture reference; electrodes are selected separately. Tap or click the image for a larger view.

Select the ion.
Then the electrode.

PION400 supports pX, mol/L, ppm and mg/L reporting, with built-in ion selections and a user-defined option. The connected electrode and method determine the usable concentration range and sample conditions.

A meter’s pX display range is not a universal detection limit for every ion. Select a compatible electrode, suitable standards and the correct conditioning solution for the sample.

Add pH to
the ion-testing workflow.

The platform supports 0.00–14.00 pH at 0.01 pH resolution and ±0.01 pH ±1 digit meter accuracy. Automatic pH calibration supports one to three points.

The pH electrode’s own sample limits and care routine remain separate from the ISE method. Confirm the required electrode configuration before ordering this platform.

Apera PION400 platform in pH mode; the pictured electrode is a configuration reference.
Apera PION400 platform in pH mode; the pictured electrode is a configuration reference. Tap or click the image for a larger view.
Manufacturer checklist of factors affecting ISE measurement stability.
Manufacturer checklist of factors affecting ISE measurement stability. Tap or click the image for a larger view.

Control what changes
the ion reading.

Ion activity, sample pH, temperature, interfering ions, contamination and the condition of the sensing membrane can all affect an ISE measurement. Prepare standards and samples consistently.

Use the appropriate one- to three-point ion calibration method. A concentration result is not automatically a total-element result after digestion or a direct reading of another chemical species.

What this order includes.

Order detail Configuration
Product PION400
Manufacturer part number AI4326
Blue Tiger SKU BTS-AI4326
Order contents PION400 platform configuration. Ion-specific electrodes, calibration standards and conditioning reagents must be selected for the intended method; complete named-ion kits are listed separately. Confirm the required packing configuration with Blue Tiger Scientific before ordering.

Check the fit
before ordering.

Specification Detail
Measurement modes pH / mV / ion / temperature
pH range / accuracy 0.00–14.00 / ±0.01 pH ±1 digit
Ion display range 0.00–14.00 pX; electrode-specific concentration range
Ion units pX / mol/L / ppm / mg/L
Ion calibration 1–3 points, manual
Temperature platform range 0–100°C; electrode limits may be lower
Protection IP57

Match the stated limits and configuration to your procedure. The Product Specifications tab repeats the order details for quick reference.

Compare related products.

Apera Instruments PION400-K Portable pH/Potassium Ion Meter Kit

Apera Instruments PION400-NH Portable pH/Ammonium Ion/TAN Meter Kit

Apera Instruments ION400-K Portable Potassium Ion Meter Kit

PION400 buyer questions

Is this the same as a PION400-K complete kit?

No. This is the base platform listing. Named-ion kits specify a particular sensing and calibration configuration.

Does it measure pH as well as ions?

Yes. PION400 adds pH measurement to the ion, mV and temperature platform, with an appropriate connected electrode.

Which ion can I measure?

Select the matching ISE, calibration standards and sample method. The meter’s ion selection alone does not make an electrode sensitive to another ion.

Does the pX range define every electrode’s detection limit?

No. The usable ion concentration range and sample window are specific to the chosen electrode and method.

Which units are available?

The catalog lists pX, mol/L, ppm and mg/L for ion reporting.

How many ion calibration points are supported?

The platform supports one- to three-point manual ion calibration.

Can one electrode measure every ion?

No. Different target ions require the appropriate selective membrane and sample-conditioning method.

What must I confirm before ordering?

Confirm the intended ion, electrode connection, calibration standards, conditioning reagents and exact packing configuration. Choose a named-ion kit for a defined complete setup.

Choose the configuration
that fits your work.

Review the order contents and the required electrode and calibration setup before ordering. Contact Blue Tiger Scientific if you need help matching the part.

Back to price and ordering ↑

    PION400 specifications

    SpecificationDetail
    Measurement modespH / mV / ion / temperature
    pH range / accuracy0.00–14.00 / ±0.01 pH ±1 digit
    Ion display range0.00–14.00 pX; electrode-specific concentration range
    Ion unitspX / mol/L / ppm / mg/L
    Ion calibration1–3 points, manual
    Temperature platform range0–100°C; electrode limits may be lower
    ProtectionIP57

    Ordering information

    SpecificationDetail
    Manufacturer part numberAI4326
    Blue Tiger SKUBTS-AI4326
    Order contentsPION400 platform configuration. Ion-specific electrodes, calibration standards and conditioning reagents must be selected for the intended method; complete named-ion kits are listed separately. Confirm the required packing configuration with Blue Tiger Scientific before ordering.

    Manufacturer warranty support is subject to Apera’s terms for the specific product and the cause of the issue. Keep your purchase record and product identification for a support request.

    For setup, compatibility or troubleshooting support, contact Blue Tiger Scientific with the model, order number and a description of the issue.

    Contact Blue Tiger Scientific before returning a product. Return eligibility and instructions depend on the store’s applicable return policy and the condition of the item.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat