Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera PH8500-A Portable pH Meter with Temperature Probe Only and GLP Data Logging (AI5592) Portable pH Meter Apera Instruments
Apera PH8500-A Portable pH Meter with Temperature Probe Only and GLP Data Logging (AI5592) Portable pH Meter Apera Instruments
Apera PH8500-A Portable pH Meter with Temperature Probe Only and GLP Data Logging (AI5592) Portable pH Meter Apera Instruments
Apera PH8500-A Portable pH Meter with Temperature Probe Only and GLP Data Logging (AI5592) Portable pH Meter Apera Instruments
Apera PH8500-A Portable pH Meter with Temperature Probe Only and GLP Data Logging (AI5592) Portable pH Meter Apera Instruments
Apera PH8500-A Portable pH Meter with Temperature Probe Only and GLP Data Logging (AI5592) Portable pH Meter Apera Instruments
Apera PH8500-A Portable pH Meter with Temperature Probe Only and GLP Data Logging (AI5592) Portable pH Meter Apera Instruments
Apera PH8500-A Portable pH Meter with Temperature Probe Only and GLP Data Logging (AI5592) Portable pH Meter Apera Instruments
Apera PH8500-A Portable pH Meter with Temperature Probe Only and GLP Data Logging (AI5592) Portable pH Meter Apera Instruments
Apera PH8500-A Portable pH Meter with Temperature Probe Only and GLP Data Logging (AI5592) Portable pH Meter Apera Instruments

Apera PH8500-A Portable pH Meter with Temperature Probe Only and GLP Data Logging (AI5592)

$359.00

    PH8500-A pairs the PH8500 meter platform with a temperature probe so you can select your own application-specific pH electrode. GLP data logging and USB output support measurement records as well as field testing.

    • Configuration: Temperature probe only; pH electrode sold separately
    • pH range: 0.00–14.00 pH
    • pH resolution: 0.1 / 0.01 pH

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / PH8500-A / AI5592

Your pH electrode.
GLP records to match.

PH8500-A pairs the PH8500 meter platform with a temperature probe so you can select your own application-specific pH electrode. GLP data logging and USB output support measurement records as well as field testing.

PH8500 meter platform reference; the pH electrode is ordered separately for the -A configuration.
PH8500 meter platform reference; the pH electrode is ordered separately for the -A configuration. Tap or click the image for a larger view.
Choose the right meter configurationClick or tap to compare your optionsCompare below — click or tap here to close

Compare the selected product with the related listings below. Check the application, connection and order contents before choosing.

Linked cards open current store listings. Other cards compare configurations; they do not imply current storefront availability.

PH8500-A — Manufacturer product and feature reference
PH8500-A — Manufacturer product and feature reference. Tap or click the image for a larger view.

Choose the electrode
for your sample.

PH8500-A is the temperature-probe-only configuration of the PH8500 platform. A pH electrode is not supplied, making it useful when you already own an appropriate BNC electrode or want to choose one for a specific sample.

Match the pH sensing glass and reference design to the sample, then confirm the meter connection. Organic solvents, high-viscosity samples, pure water and semi-solid foods can require different electrodes.

Calibrate with guidance.
Measure with a stable endpoint.

The platform supports one- to three-point automatic pH calibration and displays pH with temperature. A stability indication helps identify when the reading has settled.

Use fresh buffers that bracket the expected sample pH. Verify the selected buffer standard, connect the temperature probe and allow the sample to reach a stable temperature before recording results.

PH8500 manufacturer display feature graphic.
PH8500 manufacturer display feature graphic. Tap or click the image for a larger view.
PH8500 instrument housing and stand reference.
PH8500 instrument housing and stand reference. Tap or click the image for a larger view.

Field handling.
Bench convenience.

The IP57 instrument enclosure and protective boot suit portable work. A folding stand provides an angled view at the bench.

A rating for the meter enclosure does not give a connected electrode the same temperature or immersion limits. Keep plugs clean and dry and follow the electrode’s own care instructions.

Keep the measurement
with its record.

PH8500 adds GLP data management, manual or automatic logging, a real-time clock and USB output through the specified PC-link software. It stores up to 500 data groups.

Plan the electrode, calibration standards and data-transfer workflow together. The application photo illustrates the platform in use; the shown pH electrode is not part of PH8500-A.

What this order includes.

Order detail Configuration
Product PH8500-A
Manufacturer part number AI5592
Blue Tiger SKU BTS-AI5592
Order contents PH8500 meter with temperature probe only. pH/ORP electrodes and their application-specific standards are separate; parent-kit photos or manuals do not define the -A packing list.

Check the fit
before ordering.

Specification Detail
Configuration Temperature probe only; pH electrode sold separately
pH range 0.00–14.00 pH
pH resolution 0.1 / 0.01 pH
pH accuracy ±0.01 pH ±1 digit
Calibration 1–3 points, automatic
Temperature range 0–100°C; electrode limits may be lower
Connections BNC for pH/ORP; RCA for temperature
Protection IP57
Data storage 500 groups
Data output USB via specified PC-link software
Logging Manual / automatic; GLP data management

Match the stated limits and configuration to your procedure. The Product Specifications tab repeats the order details for quick reference.

Compare related products.

Apera PH850 Portable pH Meter Kit with 201T-F Electrode

Apera PH8500 Portable pH Meter Kit with 201T-F Electrode and USB Data Logging

Apera 602 Flexible Electrode Holder (AI2810)

PH8500-A buyer questions

Is a pH electrode included?

No. This -A configuration is listed with a temperature probe only. Choose a compatible pH electrode separately.

Can I use a BNC pH electrode?

The platform accepts BNC pH electrodes. Confirm the electrode’s sample suitability and the separate temperature connection before ordering.

Why include a temperature probe?

The temperature probe supports temperature measurement and automatic compensation with a separate pH electrode that has no built-in temperature sensor.

What pH accuracy is specified?

The meter electronics are specified at ±0.01 pH ±1 digit. Actual sample performance also depends on the electrode, calibration and method.

How many calibration points does it support?

One to three points with automatic buffer recognition. Select the buffer standard required by your procedure.

Does it measure ORP?

The platform provides mV measurement with a compatible ORP electrode. The ORP electrode is separate.

Does this model export data?

PH8500 provides GLP logging and USB output using the specified software.

Do the parent-kit photos show everything included?

No. Platform/application photos may show a pH electrode or other items from a complete kit. The -A order is the temperature-probe-only configuration.

Choose the configuration
that fits your work.

Review the order contents and the required electrode and calibration setup before ordering. Contact Blue Tiger Scientific if you need help matching the part.

Back to price and ordering ↑

    PH8500-A specifications

    SpecificationDetail
    ConfigurationTemperature probe only; pH electrode sold separately
    pH range0.00–14.00 pH
    pH resolution0.1 / 0.01 pH
    pH accuracy±0.01 pH ±1 digit
    Calibration1–3 points, automatic
    Temperature range0–100°C; electrode limits may be lower
    ConnectionsBNC for pH/ORP; RCA for temperature
    ProtectionIP57
    Data storage500 groups
    Data outputUSB via specified PC-link software
    LoggingManual / automatic; GLP data management

    Ordering information

    SpecificationDetail
    Manufacturer part numberAI5592
    Blue Tiger SKUBTS-AI5592
    Order contentsPH8500 meter with temperature probe only. pH/ORP electrodes and their application-specific standards are separate; parent-kit photos or manuals do not define the -A packing list.

    Manufacturer warranty support is subject to Apera’s terms for the specific product and the cause of the issue. Keep your purchase record and product identification for a support request.

    For setup, compatibility or troubleshooting support, contact Blue Tiger Scientific with the model, order number and a description of the issue.

    Contact Blue Tiger Scientific before returning a product. Return eligibility and instructions depend on the store’s applicable return policy and the condition of the item.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat