Apera IndSen 2071M-NO-TS Nitrate Ion/Temperature Electrode (AI4524) Ion Selective Electrode Apera Instruments
Apera IndSen 2071M-NO-TS Nitrate Ion/Temperature Electrode (AI4524) Ion Selective Electrode Apera Instruments
Apera IndSen 2071M-NO-TS Nitrate Ion/Temperature Electrode (AI4524) Ion Selective Electrode Apera Instruments
Apera IndSen 2071M-NO-TS Nitrate Ion/Temperature Electrode (AI4524) Ion Selective Electrode Apera Instruments
Apera IndSen 2071M-NO-TS Nitrate Ion/Temperature Electrode (AI4524) Ion Selective Electrode Apera Instruments
Apera IndSen 2071M-NO-TS Nitrate Ion/Temperature Electrode (AI4524) Ion Selective Electrode Apera Instruments
Apera IndSen 2071M-NO-TS Nitrate Ion/Temperature Electrode (AI4524) Ion Selective Electrode Apera Instruments
Apera IndSen 2071M-NO-TS Nitrate Ion/Temperature Electrode (AI4524) Ion Selective Electrode Apera Instruments
Apera IndSen 2071M-NO-TS Nitrate Ion/Temperature Electrode (AI4524) Ion Selective Electrode Apera Instruments
Apera IndSen 2071M-NO-TS Nitrate Ion/Temperature Electrode (AI4524) Ion Selective Electrode Apera Instruments

Apera IndSen 2071M-NO-TS Nitrate Ion/Temperature Electrode (AI4524)

$490.00

    Nitrate ion measurement with a dedicated IndSen combination electrode.

    • Electrode range: 0.62–62,000 mg/L
    • Sample window: pH 4.6–8; 5–50°C
    • Membrane: Ultra-firm PVC
    • Match the exact meter connection and temperature support

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / IndSen 2071M-NO-TS / AI4524

Selective for nitrate.
Built around the sample you measure.

The Apera IndSen 2071M-NO-TS combines a nitrate-selective measuring element, reference system and temperature function for aqueous nitrate testing for nutrient management, environmental sampling and laboratory methods. Choose this replacement electrode when your compatible meter needs a dedicated NO₃⁻ sensor.

The nitrate electrode is specified for 0.62–62,000 mg/L, sample pH 4.6–8 and 5–50°C. Use the stated sample limits and the correct ion method to select the sensor, then match it to the host meter.

Apera IndSen 2071M combination-electrode family photograph; ion-selective membrane and cable configuration vary by model.
Apera IndSen 2071M combination-electrode family photograph; ion-selective membrane and cable configuration vary by model. Tap or click the image for a larger view.
Choose your IndSen ion electrodeClick or tap to compare your optionsCompare below — click or tap here to close

Match the target ion first. Membrane chemistry and sample pH/temperature limits vary across these combination electrodes. Host-meter connection and temperature support must also match.

IndSen 2071M-NH-TS product referenceIndSen 2071M-NH-TSAmmonium (NH₄⁺) · 0.18–9000 mg/L · Ultra-firm PVCConfiguration comparison
IndSen 2071M-NO-TS product referenceIndSen 2071M-NO-TSNitrate (NO₃⁻) · 0.62–62,000 mg/L · Ultra-firm PVCCurrent configuration
IndSen 2071M-CA-TS product referenceIndSen 2071M-CA-TSCalcium (Ca²⁺) · 0.20–4008 mg/L · Ultra-firm PVCConfiguration comparison
IndSen 2071M-K-TS product referenceIndSen 2071M-K-TSPotassium (K⁺) · 10⁻⁶–1 mol/L · Ultra-firm PVCConfiguration comparison
IndSen 2071M-F-TS product referenceIndSen 2071M-F-TSFluoride (F⁻) · 0.019–1900 mg/L · CrystallineConfiguration comparison
IndSen 2071M-CL-TS product referenceIndSen 2071M-CL-TSChloride (Cl⁻) · 1.775–3550 mg/L · Solid-stateConfiguration comparison
IndSen 2071M-CU-TS product referenceIndSen 2071M-CU-TSCopper (Cu²⁺) · 0.032–6355 mg/L · Solid-stateConfiguration comparison
IndSen 2071M-BR-TS product referenceIndSen 2071M-BR-TSBromide (Br⁻) · 0.40–7990 mg/L · Solid-stateConfiguration comparison
IndSen 2071M-I-TS product referenceIndSen 2071M-I-TSIodide (I⁻) · 0.0635–12,690 mg/L · Solid-stateConfiguration comparison

Linked cards open current store listings. Other cards compare configurations; they do not imply current storefront availability.

Know what you are ordering.

One IndSen 2071M-NO-TS combination nitrate ion/temperature electrode. Meter, calibration standards and sample-conditioning reagents are purchased separately.

Ordering detail Configuration
Product IndSen 2071M-NO-TS
Manufacturer part number AI4524
Blue Tiger SKU BTS-AI4524
Order unit One replacement electrode

Understand the
ultra-firm PVC membrane.

Apera’s ultra-firm PVC design uses a solid electrolyte reservoir and ion-active materials to strengthen the sensing membrane. The manufacturer comparison illustrates how it differs from an ordinary liquid-electrolyte PVC membrane. This construction description applies to the PVC ion-electrode family.

Apera manufacturer PVC-membrane construction and comparison diagram.
Apera manufacturer PVC-membrane construction and comparison diagram. Tap or click the image for a larger view.
Apera IndSen family construction diagram. The analog 2071M is shown on the right; digital and separate measuring versions are not included.
Apera IndSen family construction diagram. The analog 2071M is shown on the right; digital and separate measuring versions are not included. Tap or click the image for a larger view.

Measuring element, reference
and temperature function.

The handbook diagram distinguishes IndSen 2071M analog combination electrodes from 2071S digital models and 1121M measuring electrodes. The analog 2071M branch is the relevant family here; the other architectures are shown for comparison.

Match the exact electrode connection and temperature support to the meter. A shared body shape or plug appearance is not sufficient to establish interchangeability.

Calibrate for the sample.
Control what affects stability.

Calibrate with suitable ion standards, then prepare standards and samples using the same method. The 400-series ion mode supports one- to three-point manual calibration; select appropriate points for the samples you expect.

Ionic strength, interfering ions, temperature, sample pH and deposits can affect the reading. Apera’s handbook checklist shows why electrode selection and sample preparation belong in the same workflow.

Manufacturer handbook checklist of factors affecting ISE measurement stability.
Manufacturer handbook checklist of factors affecting ISE measurement stability. Tap or click the image for a larger view.

Check the sample window.

Specification Detail
Target ion Nitrate
Electrode range 0.62–62,000 mg/L
Sample pH 4.6–8
Electrode temperature 5–50°C
Membrane Ultra-firm PVC

Condition and calibrate with the correct nitrate standards. Maintain the specified pH and temperature window and control interfering ions. Measures nitrate ions in the prepared aqueous sample; it does not directly report total nitrogen or nitrate-nitrogen without the correct conversion.

Condition, rinse
and store by electrode type.

Follow the instructions for this ion-selective electrode when conditioning, cleaning and storing it. Use appropriate standards to check response after maintenance. The measuring membrane and reference junction need contact with the prepared sample during measurement.

The PVC family uses solid-electrolyte technology; this does not remove the need for conditioning and calibration. Use model-specific care instructions rather than applying a general pH-probe soaking routine to every ISE.

Match the meter
and connection.

Apera catalog connector reference. Match the exact sensor, signal and temperature requirements; connector appearance alone is not a compatibility guarantee.
Apera catalog connector reference. Match the exact sensor, signal and temperature requirements; connector appearance alone is not a compatibility guarantee. Tap or click the image for a larger view.

Compare the current ION400-K, PION400-K, ION400-NH and PION400-NH platforms, then confirm this electrode’s target ion and supported connection.

Compare related products.

ION400-K meter kit — ion-only platform PION400-K meter kit — pH/ion platform 602 flexible electrode holder — separate support

IndSen 2071M-NO-TS buyer questions

What does the IndSen 2071M-NO-TS measure?

This combination ion-selective electrode measures nitrate ions (NO₃⁻) in a suitably prepared aqueous sample. It requires a compatible ion meter.

What is its nitrate measuring range?

Apera specifies 0.62–62,000 mg/L for this ion-electrode family. Calibration, sample composition and interferences determine the practical working range.

What temperature and pH conditions are required?

The specified electrode operating window is 5–50°C, with sample pH 4.6–8. Check both before selecting the sensor.

Is a separate reference electrode needed?

The combination design integrates the ion-selective measuring element and reference system. A compatible meter, standards and any method-specific conditioning solutions are still needed.

Does it include temperature measurement?

The -TS configuration is the temperature-compensated version. Confirm the meter’s connection and temperature-sensor support before ordering; matching a plug alone is not sufficient.

Can I use it to measure a different ion?

No. This version is selective for NO₃⁻. Other ions require their own electrodes and calibration.

Does this measure a total concentration?

Measures nitrate ions in the prepared aqueous sample; it does not directly report total nitrogen or nitrate-nitrogen without the correct conversion.

What should I prepare before first use?

Obtain suitable nitrate calibration standards, follow the electrode conditioning instructions, and apply the method’s pH, ionic-strength and interference controls. This listing is for the electrode, not a complete meter kit.

Confirm the exact configuration before ordering.

Review IndSen 2071M-NO-TS AI4524 against your measurement method, sample limits and host connection. Return to the price and ordering controls when the configuration fits your work.

Back to price and ordering ↑
    SpecificationDetail
    Manufacturer part numberAI4524
    Blue Tiger SKUBTS-AI4524
    ModelIndSen 2071M-NO-TS
    Target ionNitrate (NO₃⁻)
    Measurement range0.62–62,000 mg/L
    MembraneUltra-firm PVC
    Operating temperature5–50°C
    Sample pH range4.6–8
    Electrode structureCombination ISE with temperature function
    Measuring body dimensionsØ16 × 120 mm
    Connection checkConfirm meter, connector and ATC compatibility before ordering

    Ordering Information

    Ordering detailConfiguration
    Manufacturer catalogAI4524
    Blue Tiger SKUBTS-AI4524
    Order unitOne IndSen 2071M-NO-TS replacement electrode
    Order contentsOne IndSen 2071M-NO-TS combination nitrate ion/temperature electrode. Meter, calibration standards and sample-conditioning reagents are purchased separately.

    Manufacturer warranty coverage is subject to Apera’s terms for this exact product. Contact Blue Tiger Scientific for help confirming coverage or submitting a manufacturer warranty inquiry.

    For technical support, provide the manufacturer part number, meter model and a description of the issue. Blue Tiger Scientific can help coordinate product selection and manufacturer support.

    For a return request, contact Blue Tiger Scientific before sending the product back. Eligibility and any authorization requirements follow the applicable store return policy; manufacturer warranty service and store returns are separate processes.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat