Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera DO500 Polarographic Dissolved Oxygen Electrode | AI4110 Default Title Polarographic DO Probe Apera Instruments
Apera DO500 Polarographic Dissolved Oxygen Electrode | AI4110 Polarographic DO Probe Apera Instruments
Apera DO500 Polarographic Dissolved Oxygen Electrode | AI4110 Polarographic DO Probe Apera Instruments
Apera DO500 Polarographic Dissolved Oxygen Electrode | AI4110 Default Title Polarographic DO Probe Apera Instruments
Apera DO500 Polarographic Dissolved Oxygen Electrode | AI4110 Polarographic DO Probe Apera Instruments
Apera DO500 Polarographic Dissolved Oxygen Electrode | AI4110 Polarographic DO Probe Apera Instruments

Apera DO500 Polarographic Dissolved Oxygen Electrode | AI4110

$260.00

    A serviceable DO electrode for your compatible Apera meter.

    • Polarographic measurement from 0 to 19.99 mg/L and 0 to 200.0%
    • Integrated temperature and salinity sensors
    • Calibration sleeve, 30 mL refill, three caps and two polishing papers included
    • 8-pin connector for explicitly listed compatible Apera meters

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / DO500 / AI4110

Polarographic DO measurement with serviceable membrane caps

The Apera DO500 is a replacement polarographic dissolved oxygen electrode for specified Apera meters, including SX716, SX725, SX736 and SX751. Integrated temperature and salinity sensors support automatic compensation, while replaceable membrane caps and inner solution provide a documented maintenance path.

Apera DO500 electrode with calibration sleeve and three spare membrane caps
Manufacturer photograph of the DO500 electrode, sleeve and spare caps. See the contents list for the complete supplied items.
Which system is this replacement for?

CURRENT ITEM: DO500

These are selected compatible meter-system or related-workflow pages, not additional items supplied with this accessory. Match the exact probe or component in the compatibility table below.

Why choose this replacement?

Integrated compensation

Temperature compensation covers 0 to 45°C; automatic salinity compensation covers 0 to 45 ppt.

Documented response

The manufacturer specifies 90% response within 30 seconds at 25°C, with DO accuracy of ±0.30 mg/L.

Replaceable membrane system

The DO503 membrane cap and DO502 inner solution are replaceable maintenance items. The included DO504 papers are for cleaning a contaminated gold cathode as instructed.

Calibration sleeve included

The supplied sleeve supports the saturated-air calibration procedure described in the SX716 manual.

Check the exact probe and meter system.

Model or component Compatibility and role
SX716 Compatible meter. Explicitly named on the DO500 manufacturer product page. An 8-pin connector alone does not establish compatibility.
SX725 Compatible meter. Explicitly named on the DO500 manufacturer product page. An 8-pin connector alone does not establish compatibility.
SX736 Compatible meter. Explicitly named on the DO500 manufacturer product page. An 8-pin connector alone does not establish compatibility.
SX751 Compatible meter. Explicitly named on the DO500 manufacturer product page. An 8-pin connector alone does not establish compatibility.
SX726 Compatible meter. Explicitly named on the DO500 manufacturer product page. An 8-pin connector alone does not establish compatibility.
SX816 Compatible meter. Explicitly named on the DO500 manufacturer product page. An 8-pin connector alone does not establish compatibility.
SX836 Compatible meter. Explicitly named on the DO500 manufacturer product page. An 8-pin connector alone does not establish compatibility.

Optical sensor caps and polarographic membrane components are different replacement systems. A shared brand or similar appearance does not establish interchangeability.

Polarize, calibrate, then measure

For SX716 operation, connect the electrode to the powered-on meter and allow five minutes of polarization before calibration or measurement. After replacing the membrane cap or adding new inner solution, the manual requires 30 minutes of polarization instead.

For saturated-air calibration, keep the sleeve sponge moist with a few drops of distilled water, without dripping. Follow section 4.2 of the SX716 manual, including its stabilization instructions. Use the applicable meter manual for other compatible meters.

DO500 diagram identifying temperature and salinity sensors, silver anode, gold cathode and replaceable membrane cap
Manufacturer illustration of the DO500 sensor and membrane assembly.

Match the sensing system to the work.

General water solutions

The manufacturer specifies general water solutions as suitable samples. Strong acidic or alkaline water solutions and organic solutions are not suitable.

Compatible-meter replacement

Use as a replacement electrode for the listed Apera DO-capable meter models, rather than selecting on connector appearance alone.

What this order supplies

Included item Order contents
DO500 electrode 1 electrode
DO502 inner solution 1 refill, 30 mL
DO503 membrane caps 3 caps
DO504 cathode polishing paper 2 pieces
Calibration sleeve Included according to the manufacturer feature list
Apera DO500 polarographic electrode close-up
Manufacturer close-up of the DO500 electrode.

Maintain the membrane and inner solution

Inspect the membrane for wrinkles, cracks or damage and check the inner solution for air bubbles. The SX716 manual identifies slower response or obvious measurement errors as reasons to inspect and replace the membrane cap.

Use fresh DO502 solution with the DO503 replacement cap. Avoid touching the sensitive membrane with your fingers. Follow the manual for cleaning, assembly, polarization and calibration before returning to measurement.

DO500 buyer questions

Which meters are listed for DO500?

Apera lists SX716, SX725, SX726, SX736, SX751, SX816 and SX836. Confirm the exact meter model before ordering.

Does an 8-pin connector mean universal compatibility?

No. DO500 has an 8-pin connector, but compatibility here is limited to the models explicitly listed by Apera.

What comes with the electrode?

The official contents list specifies one DO500 electrode, one 30 mL DO502 refill, three DO503 caps and two DO504 polishing papers. The feature list also confirms a calibration sleeve.

How long does polarization take?

The SX716 manual specifies five minutes after power-on, or 30 minutes after a new membrane cap or new inner solution is installed.

Are temperature and salinity sensors integrated?

Yes. The DO500 manufacturer page specifies integrated temperature and salinity sensors with automatic compensation.

What water samples is it suitable for?

Apera specifies general water solutions, excluding strong acidic or alkaline water solutions and organic solutions.

Which replacement consumables should I use?

DO502 is the specified inner solution and DO503 is the specified membrane cap. DO504 polishing paper is identified for gold-cathode cleaning.

Is the linked manual a standalone DO500 manual?

No. It is the SX716 meter manual and includes DO electrode preparation, maintenance and replacement-part information.

    SpecificationDO500
    ModelDO500
    Manufacturer SKUAI4110
    Measurement technologyPolarographic
    DO measuring range0 to 19.99 mg/L (ppm); 0 to 200.0%
    DO accuracy±0.30 mg/L (ppm)
    Response time≤30 seconds at 25°C for 90% response
    Automatic temperature compensation0 to 45°C
    Automatic salinity compensation0 to 45 ppt
    Temperature range0 to 50°C (32 to 122°F)
    Temperature accuracy±0.5°C (±1.0°F)
    Operating temperature0 to 50°C (32 to 122°F)
    Housing materialsPPS; ABS storage sleeve
    Connector8-pin
    Sensor dimensions177 mm long × 15.5 mm diameter
    Cable length2 m

    Ordering Information

    Order detailConfiguration
    Manufacturer catalogAI4110
    Store SKUBTS-AI4110
    Order unitOne DO500 electrode assembly
    Order contentsDO500 electrode: 1 electrode; DO502 inner solution: 1 refill, 30 mL; DO503 membrane caps: 3 caps; DO504 cathode polishing paper: 2 pieces; Calibration sleeve: Included according to the manufacturer feature list

    DO500 documentation and service

    Follow the exact installation, polarization, calibration and maintenance instructions. Consult the warranty provided with the product for applicable standalone purchase coverage; this accessory page does not transfer the meter warranty to the electrode.